All data points collected by a CEMS shall be used to calculate individual hourly emission averages unless another applicable requirement or compliance document requires more frequent averaging. Each hourly average starts at the beginning of the hour and ends at the beginning of the following hour.
In order for an hour of data to be considered valid, it must contain the following minimum number of data points during the hour:
two data points, at least 15 minutes apart, during periods of monitor calibration, and periods of time to conduct quality control audits or routine maintenance; and
Monitoring data shall be recorded in the same units of measurement and averaging period as the facility's emission standard.