7011.1425 PERFORMANCE TEST METHODS.
§
Subpart 1.
In general.
Unless another method is approved by the commissioner, a person required to submit performance tests for a petroleum refinery must use the test methods in this part to demonstrate compliance.
§
Subp. 2.
Gases released to atmosphere from fluid catalytic cracking unit catalyst regenerator.
For gases released to the atmosphere from the fluid catalytic cracking unit catalyst regenerator:
§
A.
Method 1 for sample and velocity traverses;
§
B.
Method 2 for velocity and volumetric flow rate;
§
C.
Method 5 for the concentration of filterable particulate matter and moisture content;
§
D.
Method 9 for visual determination of the opacity of emissions from stationary sources;
§
E.
Method 10 for carbon monoxide.
§
Subp. 3.
Exhaust gases.
For exhaust gases from the fluid catalytic cracking unit catalyst regenerator prior to the emission control system:
§
A.
Method 1 for sample and velocity traverses;
§
B.
Method 2 for velocity and volumetric flow rate;
§
C.
Method 3 for gas analysis;
§
D.
Method 4 for moisture content.
§
Subp. 4.
Determination of concentration.
For determining the concentration of H2S in any fuel gas, Method 11 shall be used.
§
Subp. 5.
Gases to atmosphere from combustion.
For gases released to the atmosphere from the combustion of fuel gas, fossil fuel, and the combination of fuel gas and fossil fuel:
§
A.
Method 1 for sample and velocity traverses;
§
B.
Method 2 for velocity and volumetric flow rate;
§
C.
Method 5 for the concentration of filterable particulate matter and moisture content;
§
D.
Method 6 for concentration of SO2;
§
E.
Method 9 for visual determination of the opacity of emissions from stationary sources.
History:
L 1987 c 186 s 15; 18 SR 614; 41 SR 763