The owner or operator of a Class I waste combustor shall comply with the emission limits, notification, monitoring, testing, record-keeping, and reporting requirements of the new source performance standards incorporated in parts 7011.1291 to 7011.1294, except as provided in subpart 2. In addition, the owner or operator shall comply with the following limitations:
if the owner or operator chooses to comply with the operator certification requirements of Code of Federal Regulations, title 40, section 60.54b, as amended, by obtaining certification through the Minnesota Pollution Control Agency, then the owner or operator shall comply with parts 7011.1240, subpart 1; 7011.1281; 7011.1282; 7011.1283; and 7011.1284;
the reporting and response requirements to exceedance of continuously monitored emissions in part 7011.1260, subpart 7;
Instead of the mercury emission limits contained in Code of Federal Regulations, title 40, sections 60.52b(a)(5), 60.58b(d)(2)(ix), and 60.58b(d)(2)(x), as amended, the owner or operator of a Class I waste combustor shall comply with the mercury emission limits described in this subpart and the testing and reporting requirements of parts 7011.1265, subpart 2; and 7011.1270, item E.
Class I | ||
Mercury (short-term) | ||
For all waste combustors except those combusting RDF in spreader stokers | 80 µg/dscm or 85% removal | |
Waste combustor units combusting RDF in spreader stokers (90-day test interval) | 50 µg/dscm or 85% removal | |
Mercury (long-term) | ||
For all waste combustors except those combusting RDF in spreader stokers | 60 µg/dscm or 85% removal | |
Waste combustor units combusting RDF in spreader stokers (90-day test interval) | 30 µg/dscm or 85% removal | |
Waste combustor units combusting RDF in spreader stokers (12-month test interval) | 30 µg/dscm or 85% removal |
MS s 116.07
22 SR 1975; 39 SR 386
April 3, 2019
Official Publication of the State of Minnesota
Revisor of Statutes