The following table contains the state ambient air quality standards.
Pollutant/Air Contaminant | Primary Standard | Secondary Standard | Remarks |
Hydrogen Sulfide | 0.05 ppm by volume (70.0 micrograms per cubic meter) | 1/2 hour average not to be exceeded over 2 times per year | |
0.03 ppm by volume (42.0 micrograms per cubic meter) | 1/2 hour average not to be exceeded over 2 times in any 5 consecutive days | ||
Ozone | 0.08 ppm by volume (235 micrograms per cubic meter) | same as primary standard | daily maximum 8 hour average; the standard is attained when the average of the annual fourth-highest daily maximum 8-hour average ozone concentration is less than or equal to the standard |
Carbon Monoxide | 9 ppm by volume (10 milligrams per cubic meter) | same as primary standard | maximum 8 hour concentration not to be exceeded more than once per year |
30 ppm by volume (35 milligrams per cubic meter) | same as primary standard | maximum 1 hour concentration not to be exceeded more than once per year | |
Sulfur Dioxide | 80 micrograms per cubic meter (0.03 ppm by volume) | 60 micrograms per cubic meter (0.02 ppm by volume) | maximum annual arithmetic mean |
365 micrograms per cubic meter (0.14 ppm by volume) | same as primary standard | maximum 24 hour concentration not to be exceeded more than once per year | |
915 micrograms per cubic meter (0.35 ppm by volume) | maximum 3 hour concentration not to be exceeded more than once per year in Air Quality Control Regions 127, 129, 130, and 132 | ||
1300 micrograms per cubic meter (0.5 ppm by volume) | maximum 3 hour concentration not to be exceeded more than once per year in Air Quality Control Regions 128, 131, and 133 | ||
1300 micrograms per cubic meter (0.5 ppm by volume) | maximum 3 hour concentration not to be exceeded more than once per year | ||
1300 micrograms per cubic meter (0.5 ppm by volume) | maximum 1 hour concentration not to be exceeded more than once per year | ||
Particulate Matter | 75 micrograms per cubic meter | 60 micrograms per cubic meter | maximum annual geometric mean |
260 micrograms per cubic meter | 150 micrograms per cubic meter | maximum 24 hour concentration not to be exceeded more than once per year | |
Nitrogen Dioxide | 0.05 ppm by volume (100 micrograms per cubic meter) | same as primary standard | maximum annual arithmetic mean |
Lead | 1.5 micrograms per cubic meter | same as primary standard | maximum arithmetic mean averaged over a calendar quarter |
PM-10 | 150 micrograms per cubic meter | same as primary standard | maximum 24-hour average concentration; the standard is attained when the expected number of days per calendar year exceeding the value of the standard is equal to or less than one |
50 micrograms per cubic meter | same as primary standard | annual arithmetic mean; the standard is attained when the expected annual arithmetic mean concentration is less than or equal to the value of the standard | |
PM-2.5 | 65 micrograms per cubic meter | same as primary standard | 24-hour average concentration; the standard is attained when the 98th percentile 24-hour concentration is less than or equal to the standard |
15.0 micrograms per cubic meter | same as primary standard | annual arithmetic mean; the standard is attained when the annual arithmetic mean concentration is less than or equal to the standard |
MS s 116.07
18 SR 614; 19 SR 550; 22 SR 1237; 23 SR 2224
April 18, 2000
Official Publication of the State of Minnesota
Revisor of Statutes