Subpart 1.
Required reports.
If not reported under other parts of this chapter, a licensee must report the following events:
§
A.
source stuck in an unshielded position;
§
B.
any fire or explosion in a radiation room;
§
C.
damage to the source racks;
§
D.
failure of the cable or drive mechanism used to move the source racks;
§
E.
inoperability of the access control system;
§
F.
detection of radiation source by the product exit monitor;
§
G.
detection of radioactive contamination attributable to licensed radioactive material;
§
H.
structural damage to the pool liner or walls;
§
I.
abnormal water loss or leakage from the source storage pool; and
§
J.
pool water conductivity exceeding 100 microsiemens per centimeter.
§
Subp. 2.
Content.
A report under subpart 1 must include a telephone report within 24 hours according to part 4731.3110, subpart 3, item A, and a written report within 30 days according to part 4731.3110, subpart 3, item B.