A licensee must perform inspection and maintenance checks that include, as a minimum, each of the following at the frequency specified in the license or license application:
operability of the radiation monitor for radioactive contamination in pool water required under part 4731.6200, subpart 2, using a radiation check source, if applicable;
operability of the over-the-pool radiation monitor at underwater irradiators as required under part 4731.6090, subpart 2;
operability of the heat and smoke detectors and extinguisher system required under part 4731.6080, but without turning extinguishers on;
operability of the indicators of high and low pool water levels required under part 4731.6110, item E;
Malfunctions and defects found during inspection and maintenance checks must be repaired without undue delay.