A licensee must perform visual and operability checks on survey meters, radiographic exposure devices and associated equipment, transport and storage containers, and source changers before use on each day the equipment is to be used to ensure that the equipment is in good working condition, that the sources are adequately shielded, and that required labeling is present. Survey instrument operability must be performed using check sources or other appropriate means. If equipment problems are found, the equipment must be removed from service until repaired.
A licensee must have written procedures for:
inspection and routine maintenance, at intervals not to exceed three months or before the first use thereafter to ensure the proper functioning of components important to safety, of the following. If equipment problems are found, the equipment must be removed from service until repaired:
inspection and maintenance necessary to maintain the Type B packaging used to transport radioactive materials. The inspection and maintenance program must include procedures to ensure that Type B packages are shipped and maintained according to the certificate of compliance or other approval; and
29 SR 755
March 12, 2009
Official Publication of the State of Minnesota