Part | Title |
---|---|
4725.0050 | GENERAL. |
4725.0100 | DEFINITIONS. |
4725.0150 | INCORPORATIONS BY REFERENCE AND ABBREVIATIONS. |
4725.0200 | APPLICATION TO ALL WELLS AND BORINGS. |
4725.0250 | ENFORCEMENT. |
4725.0300 | [Repealed, 17 SR 2773] |
4725.0350 | FEES APPLICABLE TO THIS CHAPTER. |
4725.0400 | [Repealed, 15 SR 1597] |
4725.0410 | VARIANCE. |
4725.0450 | [Repealed, 17 SR 2773] |
LICENSING AND REGISTRATION | |
4725.0475 | ACTIVITIES REQUIRING LICENSURE OR REGISTRATION. |
4725.0500 | [Repealed, 17 SR 2773] |
4725.0550 | CERTIFIED REPRESENTATIVE OR INDIVIDUAL WELL CONTRACTOR. |
4725.0600 | [Repealed, 15 SR 78] |
4725.0650 | EXPERIENCE REQUIREMENTS; CERTIFIED REPRESENTATIVE AND INDIVIDUAL WELL CONTRACTOR. |
4725.0700 | [Repealed, 17 SR 2773] |
4725.0800 | [Repealed, 15 SR 78] |
4725.0900 | COUNCIL EVALUATION OF APPLICANTS. |
4725.1000 | [Repealed, 17 SR 2773] |
4725.1025 | EXAMINATION. |
4725.1050 | [Repealed, 17 SR 2773] |
4725.1075 | APPLICATION FOR LICENSURE OR REGISTRATION. |
4725.1100 | [Repealed, 15 SR 78] |
4725.1200 | [Repealed, 15 SR 78] |
4725.1250 | BONDING. |
4725.1300 | LICENSE OR REGISTRATION RENEWAL. |
4725.1310 | CERTIFICATION RENEWAL. |
4725.1325 | [Repealed, 17 SR 2773] |
4725.1350 | [Repealed, 17 SR 2773] |
4725.1400 | [Repealed, 17 SR 2773] |
4725.1500 | DISCIPLINARY ACTION; RETURN OF DOCUMENTS. |
4725.1600 | REAPPLICATION AFTER CERTIFICATION, LICENSE, OR REGISTRATION REVOCATION. |
4725.1650 | CONTINUING EDUCATION REQUIREMENTS. |
4725.1675 | CRITERIA FOR CONTINUING EDUCATION. |
4725.1685 | ADVISORY COUNCIL REVIEW OF CONTINUING EDUCATION PROGRAMS. |
4725.1700 | PLACEMENT OF DECALS AND LICENSE OR REGISTRATION NUMBER. |
4725.1800 | DRILLING MACHINE AND HOIST REGISTRATION. |
4725.1810 | PERMITS AND NOTIFICATIONS, GENERAL. |
PERMITS AND NOTIFICATIONS | |
4725.1820 | NOTIFICATION FOR CONSTRUCTION OF WATER-SUPPLY WELLS. |
4725.1825 | DEWATERING WELL CONSTRUCTION NOTIFICATION. |
4725.1830 | MONITORING WELL CONSTRUCTION PERMIT. |
4725.1831 | GROUNDWATER THERMAL EXCHANGE DEVICE PERMITS. |
4725.1832 | NOTIFICATION FOR WELL SEALING. |
4725.1833 | BORED GEOTHERMAL HEAT EXCHANGER CONSTRUCTION PERMITS. |
4725.1835 | ELEVATOR BORING CONSTRUCTION PERMITS. |
4725.1836 | NOTIFICATION AND PERMIT FEES. |
4725.1837 | EXCEPTION TO NOTIFICATION AND PERMIT REQUIREMENTS. |
4725.1838 | EMERGENCY NOTIFICATIONS AND PERMITS. |
4725.1840 | UNSUCCESSFUL COMPLETION OF A WELL OR BORING. |
4725.1842 | APPROVAL OF CONSTRUCTION PERMITS. |
4725.1845 | DENIAL OF CONSTRUCTION PERMIT APPLICATION. |
4725.1848 | WELL MAINTENANCE PERMITS. |
4725.1849 | PROPERTY OWNER OR LESSEE DRIVE-POINT WATER-SUPPLY WELL CONSTRUCTION NOTIFICATION. |
4725.1850 | [Repealed, 15 SR 78] |
4725.1851 | WELL AND BORING RECORDS. |
4725.1855 | CUTTING FORMATION SAMPLES. |
4725.1860 | [Repealed, 17 SR 2773] |
4725.1900 | [Repealed, 17 SR 2773] |
4725.2000 | [Repealed, 17 SR 2773] |
WELL AND BORING GENERAL CONSTRUCTION AND USE REQUIREMENTS | |
4725.2010 | APPLICABILITY. |
4725.2020 | INTERCONNECTION OF AQUIFERS PROHIBITED. |
4725.2050 | USE OF WELLS OR BORINGS FOR DISPOSAL OR INJECTION PROHIBITED. |
4725.2100 | [Repealed, 17 SR 2773] |
4725.2150 | REQUIRED DISTANCE FROM GAS PIPES, LIQUID PROPANE TANKS, AND ELECTRIC LINES. |
4725.2175 | LOCATION OF WELL OR BORING WITHIN BUILDING. |
4725.2185 | DISTANCE FROM A BUILDING. |
4725.2200 | [Repealed, 17 SR 2773] |
4725.2250 | GENERAL CASING REQUIREMENTS. |
4725.2300 | [Repealed, 17 SR 2773] |
4725.2350 | STEEL CASING REQUIREMENTS. |
4725.2400 | [Repealed, 17 SR 2773] |
4725.2450 | [Repealed, 33 SR 211] |
4725.2500 | [Repealed, 17 SR 2773] |
4725.2550 | PLASTIC CASING AND COUPLING REQUIREMENTS. |
4725.2600 | [Repealed, 17 SR 2773] |
4725.2650 | PLASTIC CASING INSTALLATION. |
4725.2700 | [Repealed, 17 SR 2773] |
4725.2750 | SCREENS; SCREEN LEADERS, RISERS, AND SUMPS. |
4725.2800 | [Repealed, 17 SR 2773] |
4725.2850 | GRAVEL PACKS. |
4725.2900 | [Repealed, 17 SR 2773] |
4725.2950 | DRILLING FLUIDS. |
4725.2975 | DISPOSAL OF MATERIALS. |
4725.3000 | [Repealed, 8 SR 1625] |
4725.3050 | GROUTING. |
4725.3100 | [Repealed, 17 SR 2773] |
4725.3150 | CASING CONNECTIONS AND CAPS. |
4725.3200 | [Repealed, 17 SR 2773] |
4725.3250 | PUMPS AND PUMPING EQUIPMENT. |
4725.3300 | [Repealed, 17 SR 2773] |
4725.3350 | INTERCONNECTIONS AND CROSS CONNECTIONS. |
4725.3400 | [Repealed, 17 SR 2773] |
4725.3450 | FLOWING WELL OR BORING. |
4725.3500 | [Repealed, 17 SR 2773] |
4725.3550 | WELL LABEL. |
4725.3600 | [Repealed, 17 SR 2773] |
4725.3650 | SPECIAL WELL AND BORING CONSTRUCTION AREAS. |
4725.3700 | [Repealed, 17 SR 2773] |
4725.3725 | CHEMICAL TREATMENT AND REHABILITATION. |
4725.3750 | REPAIR, CORRECTION, OR SEALING OF WELLS AND BORINGS. |
4725.3800 | [Repealed, 17 SR 2773] |
4725.3850 | SEALING WELL OR BORING. |
4725.3875 | RESPONSIBILITY FOR SEALING. |
4725.3900 | [Repealed, 17 SR 2773] |
4725.4000 | [Repealed, 17 SR 2773] |
WATER-SUPPLY WELLS | |
4725.4050 | APPLICABILITY. |
4725.4100 | [Repealed, 17 SR 2773] |
4725.4150 | BENTONITE DRILLING FLUIDS. |
4725.4200 | [Repealed, 17 SR 2773] |
4725.4250 | LIMESTONE OR DOLOMITE WATER-SUPPLY WELLS. |
4725.4300 | [Repealed, 17 SR 2773] |
4725.4350 | WATER-SUPPLY WELL DISTANCE FROM WATER BODIES; PROTECTIONS IN FLOOD AREAS. |
4725.4400 | [Repealed, 17 SR 2773] |
4725.4450 | WATER-SUPPLY WELL DISTANCES FROM CONTAMINATION. |
4725.4500 | [Repealed, 17 SR 2773] |
4725.4550 | MINIMUM PROTECTIVE DEPTH. |
4725.4600 | [Repealed, 17 SR 2773] |
4725.4650 | SEDIMENT IN POTABLE WATER-SUPPLY WELLS. |
4725.4700 | [Repealed, 17 SR 2773] |
4725.4750 | LEAD PROHIBITION IN POTABLE WATER-SUPPLY WELLS. |
4725.4800 | [Repealed, 17 SR 2773] |
4725.4825 | NONPOTABLE WATER-SUPPLY WELLS. |
4725.4850 | WATER-SUPPLY WELL PITLESS ADAPTER OR PITLESS UNIT, AND WELDED OR THREADED FITTING. |
4725.4900 | [Repealed, 17 SR 2773] |
4725.4950 | [Repealed, 33 SR 211] |
4725.5000 | [Repealed, 17 SR 2773] |
4725.5050 | PRIMING WATER-SUPPLY WELL PUMPS. |
4725.5100 | [Repealed, 17 SR 2773] |
4725.5150 | WATER-SUPPLY WELL SUCTION LINE. |
4725.5200 | [Repealed, 17 SR 2773] |
4725.5250 | WATER-SUPPLY WELL PUMP DISCHARGE LINES. |
4725.5300 | [Repealed, 17 SR 2773] |
4725.5350 | PRESSURE TANKS FOR WATER-SUPPLY WELLS. |
4725.5400 | [Repealed, 17 SR 2773] |
4725.5450 | VENTING WATER-SUPPLY WELLS. |
4725.5475 | HYDROFRACTURING WATER-SUPPLY WELLS. |
4725.5500 | [Repealed, 17 SR 2773] |
4725.5550 | WATER-SUPPLY WELL DISINFECTION. |
4725.5600 | [Repealed, 17 SR 2773] |
4725.5650 | WATER QUALITY SAMPLES FROM NEWLY CONSTRUCTED POTABLE WATER-SUPPLY WELL. |
4725.5675 | [Repealed, 33 SR 211] |
4725.5700 | [Repealed, 17 SR 2773] |
4725.5750 | DUG WATER-SUPPLY WELLS. |
4725.5800 | [Repealed, 17 SR 2773] |
4725.5825 | PUBLIC WATER-SUPPLY WELLS. |
4725.5850 | COMMUNITY PUBLIC WATER-SUPPLY WELLS. |
4725.5900 | [Repealed, 17 SR 2773] |
4725.6000 | [Repealed, 17 SR 2773] |
4725.6050 | REMEDIAL WATER-SUPPLY WELLS. |
4725.6100 | [Repealed, 17 SR 2773] |
DEWATERING WELLS | |
4725.6150 | DEWATERING WELL. |
4725.6200 | [Repealed, 17 SR 2773] |
4725.6300 | [Repealed, 17 SR 2773] |
4725.6400 | [Repealed, 17 SR 2773] |
MONITORING WELLS | |
4725.6450 | APPLICABILITY AND USE. |
4725.6500 | [Repealed, 17 SR 2773] |
4725.6600 | [Repealed, 17 SR 2773] |
4725.6650 | CONSTRUCTION OF MONITORING WELLS. |
4725.6700 | [Repealed, 17 SR 2773] |
4725.6750 | [Repealed, 17 SR 2773] |
4725.6755 | PROTECTION OF MONITORING WELLS. |
4725.6775 | REPAIR; SEALING OF MONITORING WELL. |
4725.6800 | [Repealed, 17 SR 2773] |
4725.6850 | AT-GRADE MONITORING WELL. |
4725.6900 | [Repealed, 17 SR 2773] |
4725.7000 | [Repealed, 17 SR 2773] |
4725.7050 | BORED GEOTHERMAL HEAT EXCHANGERS. |
4725.7100 | [Repealed, 17 SR 2773] |
4725.7200 | [Repealed, 17 SR 2773] |
4725.7250 | ELEVATOR BORINGS. |
4725.7400 | [Repealed, 17 SR 2773] |
ENVIRONMENTAL BORE HOLES | |
4725.7450 | ENVIRONMENTAL BORE HOLES. |
4725.7500 | [Repealed, 17 SR 2773] |
4725.7600 | [Repealed, 17 SR 2773] |
4725.7605 | [Repealed, 17 SR 2773] |
This chapter is adopted according to and must be read in conjunction with Minnesota Statutes, chapter 103I, relating to wells, borings, and underground uses.
MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773
September 2, 2008
Terms used in this chapter that are defined in Minnesota Statutes, section 103I.005, have the meanings given in statute. For the purposes of this chapter, the terms defined in this part have the meanings given them.
"Absorption area" has the meaning given in part 7080.1100, subpart 2, and includes the area of soil designed to absorb sewage effluent.
"Agricultural chemical" has the meaning in Minnesota Statutes, section 18D.01, subdivision 3.
"Animal unit" has the meaning in part 7020.0300, subpart 5, and is a unit of measure comparing the production of animal manure. One animal unit is equal to one slaughter steer, one horse, or for animals not listed in part 7020.0300, subpart 5, the average weight of the animal in pounds divided by 1,000.
"Annular space" means the space between two cylindrical objects one of which surrounds the other, such as the space between a bore hole and a casing pipe, or between a casing pipe and liner pipe.
"Aquifer" means a stratum of saturated, permeable bedrock or unconsolidated material having a recognizable water table or potentiometric surface which is capable of producing water to supply a well.
"At-grade" means the termination of a well or boring at the established ground surface.
"Bedrock" means a consolidated or coherent, hard, naturally formed aggregation of rock in the earth. Bedrock includes geologic materials deposited prior to the Cretaceous geologic period, and includes igneous and metamorphic rock such as granite, basalt, and iron formation, and sedimentary rock including sandstone, limestone, and shale. Bedrock includes sandstone formations such as the St. Peter or Jordan that may be semiconsolidated. Bedrock does not include alluvium, glacial drift, glacial outwash, glacial till, saprolite, or soil. For the purposes of this chapter, bedrock does not include mineral matter deposited during, or more recently than, the Cretaceous geologic period, or weathered portions of the formation surface where more than 50 percent of the parent bedrock is altered to an unconsolidated state.
"Bentonite" means an aluminum silicate clay that contains at least 85 percent of the mineral montmorillonite and meets API specification 13A-04.
"Bentonite grout" means water and a minimum of 15 percent by weight of powdered or granular bentonite, with no additives to promote temporary viscosity. An additional 15 percent by weight of either washed sand or cuttings taken from the bore hole may be mixed into the bentonite and water slurry. The bentonite must be designed by the manufacturer as a grout or well and boring sealant, and must be mixed according to the manufacturer's specifications.
"Bored geothermal heat exchanger" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 1a, and includes bored geothermal heat exchanger piping installed in a boring for thermal conductivity testing. Bored geothermal heat exchanger does not include a closed-loop piping system installed in a boring 15 feet or less below the established ground surface.
"Bored geothermal heat exchanger contractor" means a person issued a limited well/boring contractor's license for constructing, repairing, and sealing bored geothermal heat exchangers.
"Bored geothermal heat exchanger piping" means the pipe and fittings of a bored geothermal heat exchanger installed and buried below the ground surface and includes:
"Boring" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 2, and includes environmental bore holes, bored geothermal heat exchangers, and elevator borings, except that for the purposes of this chapter, boring does not include exploratory borings regulated under chapter 4727.
"Casing" means a pipe or curbing placed in a well or boring to:
prevent gas, water, or other fluids from entering the well or boring except through the screen, open hole, or perforated casing.
"Casing vent" means an outlet at the upper terminal of a casing, cap, or cover to allow equalization of air pressure in the casing and escape of toxic or flammable gases when present.
"Cement-sand grout" means a fluid mixture of Portland cement, sand, and water in the proportion of 94 pounds of Portland cement, not more than 1.0 cubic foot of dry sand, and not more than six gallons of water. Admixtures to reduce permeability or control setting time must meet ASTM Standard C494/C494M-04.
"Certified representative" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 2a, and means an individual who acts on behalf of a licensee or registrant.
"Cesspool" means an underground pit into which raw household sewage or other untreated liquid waste is discharged and from which the liquid seeps into the surrounding soil.
"Community water system" has the meaning given in Code of Federal Regulations, title 40, section 141.2, and means a public water system that serves at least 15 service connections used by year-round residents, or regularly serves at least 25 year-round residents.
"Completion of work" means the date on which the installation of the pump or pumping equipment is finished, the date on which construction of the well or boring is completed if a pump or pumping equipment is not installed by the person constructing the well or boring, the date that construction work regulated by this chapter is completed, the date the well or boring is put into service, or the date that the permit or notification expires, whichever occurs first.
"Concrete" means a mixture of Portland cement, sand and gravel aggregate, and water so that one cubic yard of concrete contains a minimum of 470 pounds (five 94-pound bags) of Portland cement, a maximum of 30 gallons of water, and sand and gravel aggregate passing a one-inch sieve. Admixtures to reduce permeability or control setting time must meet ASTM Standard C494/C494M-04.
"Confining layer" means a stratum of a geologic material that restricts vertical water movement. A confining layer includes:
a stratum at least ten feet in vertical thickness of unconsolidated materials or bedrock, that has a vertical hydraulic conductivity of 10-6 centimeters per second or less;
a stratum at least ten feet in vertical thickness of clay, sandy clay, or silty clay as defined by the United States Department of Agriculture in Handbook 18; or
a stratum at least ten feet in vertical thickness of the St. Lawrence or Eau Claire sedimentary bedrock formation, or a stratum at least two feet in vertical thickness of the Decorah or Glenwood sedimentary bedrock formation, as described in "Geology of Minnesota: A Centennial Volume" by Sims, P.K., and Morey, G.B., pages 459-473, "Paleozoic Lithostratigraphy of Southeastern Minnesota" by George Austin, which is incorporated by reference. The publication is available at the Minnesota Geological Survey, Minnesota Department of Health, or through the Minitex interlibrary loan program.
"Confining materials" means geologic materials that restrict vertical water movement. Confining materials include:
unconsolidated material or bedrock that has a vertical hydraulic conductivity of 10-6 centimeters per second or less;
clay, sandy clay, or silty clay as defined by the United States Department of Agriculture in Handbook 18 which is incorporated by reference; or
the Decorah, Glenwood, St. Lawrence, or Eau Claire sedimentary bedrock formations, as described in "Geology of Minnesota: A Centennial Volume" by Sims, P.K., and Morey, G.B., pages 459-473, "Paleozoic Lithostratigraphy of Southeastern Minnesota" by George Austin, which is incorporated by reference.
"Contact hour" means a minimum of 50 minutes of lecture, demonstration, workshop, or training excluding coffee breaks, registration, meals, or social activities.
"Council" means the Advisory Council on Wells and Borings created under Minnesota Statutes, chapter 103I.
"Cuttings" means a mixture of drilling fluid, ground up rock, and unconsolidated material removed from a well or boring.
"Dewatering well" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 4a. Dewatering well includes a temporary well for construction dewatering greater than 25 feet deep, and permanent dewatering wells. Dewatering well does not include:
a well used to lower groundwater levels for control or removal of groundwater contamination regulated as a remedial well; or
a drain tile, perforated pipe, sump, or pit less than ten feet deep, or less than ten feet below the floor of a basement, used to lower groundwater levels for construction or use of underground space.
"Dewatering well contractor" means a person issued a limited well/boring contractor's license to construct, repair, and seal dewatering wells.
"Directional drilling" means a drilling method that utilizes a steerable drill bit to cut a bore hole for installing underground pipe. Directional drilling is also known as horizontal directional drilling, or HDD.
"Drilling machine" means a motorized machine or mechanical device mounted on a truck, trailer, crawler, or skid used to excavate, drill, or bore a well or boring. A drilling machine includes a cable tool, hollow rod, auger, or rotary tool.
"Drive-point well" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 5.
"Drive-point well or dug well contractor" means a person issued a limited well/boring contractor's license to construct, repair, or seal drive-point wells or dug wells.
"Driven casing" means steel casing forced into the ground as the well or boring is advanced, where the outside diameter of the drill bit or drilling tools is equal to or less than the outside diameter of the casing, casing coupling, or drive shoe.
"Dug well" means a well that is excavated or dug with unconventional drilling equipment in which the side walls may be supported by material other than standard weight steel casing, stainless steel casing, or plastic casing as specified in this chapter. Water enters a dug well through the side walls and bottom.
"Elevator boring" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 6, and does not include cable elevators, hydraulic cylinders used to elevate automobiles, or holeless elevators where the depth of the excavation is less than ten feet below the lowest landing of the elevator.
"Elevator boring contractor" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 7.
"Environmental bore hole" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 8. An environmental bore hole must enter or go through a water bearing layer, be deeper than 25 feet or penetrate a confining layer, and be used for testing or for remediation of soil or groundwater contamination without extracting water. An environmental bore hole includes excavations used to:
remove or remediate pollution or contamination from groundwater or soil through the use of a vent, vapor recovery system, or sparge point without extracting groundwater.
"Established ground surface" means the intended or actual finished grade (elevation) of the surface of the ground at the site of a well or boring.
"Groundwater" has the meaning given in Minnesota Statutes, section 115.01, subdivision 6, and does not include water in an artificially created basin, such as a tank excavation, that is not hydrologically connected to the earth outside the basin.
"Groundwater thermal exchange device" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 11, and includes a water-supply well used to withdraw or inject groundwater for a heat pump.
"Grout" means a low permeability material used to fill the annular space around a casing, or to seal a well or boring. Grout is either neat-cement grout, cement-sand grout, or bentonite grout.
"Hazardous substance" has the meaning given in Minnesota Statutes, section 115B.02, subdivision 8.
"Hoist" means a motorized machine or mechanical device that is not a drilling machine, mounted on a truck, trailer, crawler, or skid, which is used to:
remove or install a pump or pumping equipment, casing, screen, pitless adapter, or pitless unit;
conduct an activity which requires a license or registration issued under this chapter.
Hoist does not include hand-operated equipment such as a pipe wrench, chain, pulley, or tripod.
"Holding tank" has the meaning given in part 7080.1100, subpart 40, and means a watertight tank for storage of sewage until it can be transported to a point of approved treatment and dispersal.
"Hydrofracturing" means the process of placing one or more packers into a bedrock formation and injecting potable water under pressures high enough to open existing fractures or create new fractures in the bedrock for the purpose of increasing the water yield.
"Individual well contractor" means an individual licensed according to Minnesota Statutes, section 103I.525.
"Interceptor" has the meaning given in Uniform Plumbing Code (UPC) section 211.0 as incorporated by part 4714.0050.
"Licensee" means a person who is licensed as a well contractor, limited well/boring contractor, or elevator boring contractor under this chapter and Minnesota Statutes, chapter 103I.
"Limited well/boring contractor" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 12, and includes a person with a license to: construct, repair, or seal drive-point wells or dug wells; install or repair screens or pitless units or adapters and casing from the pitless unit or adapter to the upper termination of the casing; install a well pump or pumping equipment; seal wells or borings; construct, repair, or seal a dewatering well; or construct, repair, or seal a bored geothermal heat exchanger.
"Manure storage area" has the meaning given in part 7020.0300, subpart 14, and does not include a manure storage basin.
"Manure storage basin" means a lagoon, pit, impoundment, or excavation in the ground used to store liquid and solid manure.
"Monitoring well" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 14.
"Neat-cement grout" means a fluid mixture in the proportion of 94 pounds of Portland cement and not more than six gallons of water. Bentonite up to five percent by weight of cement (4.7 pounds of bentonite per 94 pounds of Portland cement) may be used to reduce shrinkage. Not more than 0.6 additional gallons of water may be added for each one percent of bentonite. Admixtures to reduce permeability or control setting time must meet ASTM Standard C494/C494M-04. The minimum density of neat-cement grout using regular (Type 1) Portland cement without bentonite or entrained air is 15.0 pounds per gallon. The minimum density of regular neat-cement grout with bentonite and without entrained air is:
"Noncommunity water system" means a public water system that serves an average of at least 25 persons daily at least 60 days a year, at a place other than their home, and that is not a community public water system. Any water system meeting the criteria identified in this subpart that serves churches, schools, resorts, parks, camps, rest areas, or businesses is deemed to be a noncommunity water system.
"Ordinary high water level" has the meaning given in Minnesota Statutes, section 103G.005, subdivision 14.
"Person" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 16.
"Petroleum" has the meaning given in Minnesota Statutes, section 115C.02, subdivision 10.
"Petroleum bulk storage site" means a property on which petroleum products are stored for sale and excludes pipeline terminals and refineries.
"Pitless adapter" means a watertight device allowing discharge through one or more openings of a casing.
"Pitless unit" means a watertight assembly with a cap that attaches to a casing below ground, allows subsurface discharge through one or more openings, and extends the upper termination of the casing above the established ground surface.
"Pollution" or "contamination" means the presence or addition of any substance to groundwater which is or may become injurious to the health, safety, or welfare of the general public or private individuals using a well, boring, or groundwater; or which is or may become injurious to domestic, commercial, industrial, agricultural, or other uses which are being made of such water.
"Portland cement" means a construction material that conforms to ASTM Standard C150-04a, "Standard Specification for Portland Cement."
"Potable water" means water which is safe for human consumption in that it is free from impurities in amounts sufficient to cause disease or harmful physiological effects.
"Potable water-supply well" means a water-supply well used to provide water to humans for such purposes as drinking; cooking; bathing; manufacturing or processing of food, drink, or pharmaceuticals; or to supply water to plumbing fixtures accessible to humans.
"Pressure tank" or "hydropneumatic tank" means a closed water storage container constructed to operate under a designed pressure rating to modulate the water system pressure within a selected pressure range.
"Priming" means the first filling of a pump with water and the action of starting the flow in a pump.
"Public water-supply well" means a well supplying water to a public water system.
"Public water system" means a community or noncommunity water system regulated under chapter 4720.
"Pumping water level" means the distance measured from the established ground surface to the water surface in a well being pumped at a specified rate for a specified period of time.
"Rapid setting cement" means a Type III Portland cement as designated in ASTM Standard C150-04a, an API Class C cement, or any Portland cement containing calcium chloride or sodium chloride in an amount between two and four percent by weight of Portland cement, or gypsum in an amount between 20 and 100 percent by weight of Portland cement.
"Regional flood" has the meaning given in Minnesota Statutes, section 103F.111, subdivision 10.
"Registrant" means a person who is registered as a monitoring well contractor under this chapter and Minnesota Statutes, chapter 103I.
"Remedial well" means a water-supply well used to lower a groundwater level to control or remove contamination in groundwater and excludes horizontal trenches, and sumps or pits less than ten feet deep.
"Rock" means a naturally formed aggregation of mineral matter including the rocks described in part 4725.1851, subpart 4, item B.
"Sand" means unconsolidated mineral material composed principally of quartz ranging in size from 0.0025 to 0.040 inches in diameter.
"Scrap yard" means an establishment, place of business, or place of storage or deposit that is maintained, operated, or used for storing, keeping, buying, or selling scrap, junk, or waste metal obtained from automobiles, trucks, tractors, farm equipment, industrial equipment, containers, appliances, or similar items where the total scrap metal stored is greater than nine tons or consists of more than five motor vehicles.
"Screen" means a wire-wrapped, gauze, shutter, slotted, or engineered perforated pipe at the bottom of a casing designed to allow water to enter a well or boring and to prevent sediment from entering the well or boring.
"Screen leader" or "riser" means a pipe smaller in diameter than the casing that is attached to the top of a screen and telescoped into a casing.
"Sealing" means the process of preparing a well or boring to be filled with grout and the process of filling a well or boring with grout.
"Seepage pit," "leaching pit," or "dry well" means an underground pit, tank, or receptacle into which a septic tank discharges effluent or other liquid waste and from which the liquid seeps into the surrounding soil through the bottom or openings in the side of the pit, tank, or receptacle.
"Sensitive water-supply well" means a water-supply well with less than 50 feet of watertight casing where the casing does not penetrate a confining layer or multiple layers of confining materials with an aggregate thickness of ten feet or more.
"Septic tank" means a watertight tank of durable materials through which sewage flows very slowly and in which solids separate from the liquid to be decomposed or broken down by bacterial action.
"Sewage" has the meaning given in Minnesota Statutes, section 115.01, subdivision 17, and includes gray water discharge from bathing and laundry.
"Sewage sump" means a sump, dosing chamber, lift station, tank, pit, or receptacle which contains a pump to discharge sewage.
"Sewer" means a pipe or conduit carrying sewage or into which sewage may back up, including floor drains and traps.
"Soil dispersal system" has the meaning given in part 7080.1100, subpart 79, and means the piping and media such as gravel, where sewage effluent is treated and dispersed into the soil by percolation and filtration and includes trenches, seepage beds, drainfields, at-grade systems, and mound systems.
"Static water level" means the distance measured from the established ground surface to the water surface in a well or boring neither being pumped, nor under the influence of pumping nor flowing under artesian pressure.
"Storm water drain pipe" means a pipe or conduit carrying storm water or surface water from a building roof, parking lot, street, or paved area. Storm water drain pipe does not include a pipe or conduit carrying:
"Subterranean gas" means a gas occurring below the land surface. It may be flammable such as methane or highly toxic as hydrogen sulfide and may be associated with ground water.
"Suction line" means a pipe or line connected to the inlet side of a pump or pumping equipment or any connection to a casing that may conduct nonsystem water into the well or boring because of negative pressures.
"Thermally enhanced bentonite grout" means a bentonite-based grout that is mixed with sand or graphite to improve the thermal efficiency of a bored geothermal heat exchanger system.
"Total coliform bacteria" means all of the aerobic and facultative anaerobic, gram-negative, non-spore-forming, rod-shaped bacteria that ferment lactose with gas formation within 48 hours at 35 degrees centigrade.
"Tremie pipe" means a pipe or hose used to insert grout into an annular space, well, or boring.
"Unconsolidated materials" means geological materials that are not bedrock and includes alluvium, glacial drift, glacial outwash, glacial till, lacustrine deposits, loess, saprolite, soil, and those materials specified in part 4725.1851, subpart 4, item A.
"Wastewater treatment unit" has the meaning given in part 7045.0020, subpart 103.
"Water-supply well" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 20a, and includes wells used:
for testing water yields for irrigation, commercial or industrial uses, residential supply, or a public water system.
"Well" has the meaning given in Minnesota Statutes, section 103I.005, subdivision 21, and includes water-supply wells, monitoring wells, and dewatering wells.
"Well pump or pumping equipment" means a device, machine, or material used to withdraw or otherwise obtain water from a well, and all necessary seals, fittings, and pump controls. Well pump or pumping equipment does not include:
sampling devices placed in a monitoring well to obtain a water sample and are then removed after the sample is collected; or
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 156A.01 to 156A.08; 157.04; 157.08; 157.09; 157.13
8 SR 1625; 15 SR 78; 17 SR 2773; 25 SR 1207; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136; 45 SR 986
April 30, 2021
This part indicates documents, specifications, and standards that are incorporated by reference in this chapter. This material is not subject to frequent change and is available from the source listed, for loan or inspection from the Minnesota Department of Health, or through the Minitex interlibrary loan system. To borrow or inspect a reference, e-mail the Minnesota Department of Health Well Management section at health.wells@state.mn.us, or go to Search Minnesota Department of Health Library and Beyond (www.minnesotadepartmentofhealthlibrary.on.worldcat.org/discovery). The abbreviations listed in parenthesis after the source name are used in this chapter.
American Association of State Highway and Transportation Officials (AASHTO), 341 National Press Building, Washington, D.C. 20004.
AASHTO Standard H20-44, "Standard Specifications for Highway Bridges," 17th Edition, 2002, part 3.7.2.
AASHTO Standard M306-04, "Standard Specification for Drainage, Sewer, Utility, and Related Castings."
American National Standards Institute (ANSI), 25 West 43rd Street, New York, New York 10036. ANSI Schedule 5 and Schedule 40, "Dimensions of Welded and Stainless Steel Pipe" as contained in ASA Standard B36.19 - 1965, "Welded and Seamless Wrought Steel Pipe."
American Society of Mechanical Engineers, ASME International, Three Park Avenue, New York, NY 10016-5990, USA, ASME B36.10M-2000, "Welded and Seamless Wrought Steel Pipe."
ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.
ASTM A53/A53M-04a, "Standard Specifications for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless."
ASTM A589-96 (2001), Types I, II, and III, "Standard Specification for Seamless and Welded Carbon Steel Water-Well Pipe."
ASTM A312/A312M-04b, "Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes."
ASTM D2466-02, "Standard Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40."
ASTM D2487-00, "Standard Classification of Soils for Engineering Purposes (Unified Soil Classification System)."
ASTM D2683-14, "Standard Specification for Socket-Type Polyethylene Fittings for Outside Diameter-Controlled Polyethylene Pipe and Tubing."
ASTM D3035-15, "Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter."
ASTM F480-02, "Standard Specification for Thermoplastic Water Well Casing Pipe and Couplings Made in Standard Dimension Ratios (SDR), SCH 40, and SCH 80."
ASTM F714-13, "Standard Specification for Polyethylene (PE) Pipe (DR-PR) Based on Outside Diameter."
ASTM F877-20, "Standard Specification for Crosslinked Polyethylene (PEX) Hot- and Cold-Water Distribution Systems."
ASTM F1055-16, "Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene (PEX) Pipe and Tubing."
ASTM F1807-19b, "Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring, or Alternate Stainless Steel Clamps, for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing."
ASTM F1960-19a, "Standard Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing."
ASTM F2080-19, "Standard Specification for Cold-Expansion Fittings with Metal Compression-Sleeves for Crosslinked Polyethylene (PEX) Pipe and SDR9 Polyethylene of Raised Temperature (PE-RT) Pipe."
American Water Works Association, 6666 West Quincy Avenue, Denver, CO 80235, ANSI/AWWA C219-01, "Bolted, Sleeve-Type Couplings for Plain-End Pipe."
National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101, NFPA 30, "Flammable and Combustible Liquids Code, 2015 Edition."
Sims, P.K. and Morey, G.B., "Geology of Minnesota: A Centennial Volume," pages 459-473, "Paleozoic Lithostratigraphy of Southeastern Minnesota" by George Austin, 1972.
United States Department of Agriculture, Agricultural Handbook Number 18, Soil Survey Manual pages 136 to 140, October 1993.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
This chapter applies to all wells and borings except exploratory borings regulated under chapter 4727 and those wells and borings specifically exempted by Minnesota Statutes, chapter 103I.
The owner of a well or boring is bound by all the provisions of this chapter which relate to location, construction, maintenance, and sealing of wells or borings.
The licensee or registrant is responsible to:
verify information and investigate conditions to comply with the requirements of this chapter, including the location of contamination sources; and
Upon presentation of credentials, the commissioner or an employee or agent authorized by the commissioner, may examine records or data related to matters governed by Minnesota Statutes, chapter 103I, and section 144.99, of any person subject to regulation under Minnesota Statutes, chapter 103I, and, for the purpose of taking an action authorized under statute or rule, or otherwise identified in Minnesota Statutes, section 144.99, subdivision 1, relating to the enforcement of this chapter, may:
inspect drill holes and drilled, sealed, or repaired wells and borings.
This authority must be exercised during regular working hours of Department of Health inspectors with respect to inspections of bored geothermal heat exchangers and groundwater thermal exchange devices, and at reasonable times in all other cases.
This chapter applies within a political subdivision regulating construction, repair, or sealing of wells or elevator borings delegated by the commissioner under Minnesota Statutes, section 103I.111. This does not prohibit a local delegated authority from adopting an ordinance which is consistent with or more restrictive than this chapter.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 156A.01 to 156A.08; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136; 45 SR 986
April 30, 2021
The commissioner may take one or more enforcement actions for a violation of this chapter, Minnesota Statutes, chapter 103I, section 144.99 or 144.992, including:
issuing an administrative penalty order requiring a violation to be corrected, and assessing a monetary penalty under Minnesota Statutes, section 144.99, subdivision 4;
bringing an action for injunctive relief in district court under Minnesota Statutes, section 144.99, subdivision 5;
denying or refusing to renew an application for a permit, license, registration, or certificate under Minnesota Statutes, section 144.99, subdivision 8;
suspending, revoking, or imposing limitations or conditions on a permit, certification, license, or registration under Minnesota Statutes, chapter 14, and section 144.99, subdivisions 8 and 9;
enforcing the requirements of a stipulation agreement, settlement, or compliance agreement provided by Minnesota Statutes, section 144.99, subdivision 1;
using the license or registration bond to compensate persons injured or suffering financial loss because of the failure of a licensee or registrant to perform work in compliance with duties under this chapter and Minnesota Statutes, chapter 103I;
requesting prosecution by the county attorney in the county where the violation occurred or is occurring;
impounding a drilling machine or hoist used by a person who is not licensed or registered according to this chapter and Minnesota Statutes, chapter 103I; and
The person responsible for creating a violation of this chapter is responsible for correcting the violation. In the case of a violation created or constructed by a licensee or registrant, the licensee or registrant is responsible for correcting the violation. The licensee or registrant who files a notification or obtains a permit for a well or boring is responsible for the well or boring's compliance with this chapter, even if the well or boring construction is subcontracted to another person. A well or boring that cannot be corrected, must be sealed and a complying well or boring constructed, unless the well or boring owner, responsible party, and commissioner agree otherwise in a stipulated agreement.
Correction of a violation of this chapter must be completed under the supervision of the commissioner during normal business hours, within 30 days of notice of the violation, or as specified in an approved variance, work plan, or stipulation.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
The fees specified in Minnesota Statutes, chapter 103I, apply to this chapter, except:
that a federal agency, state agency, or local unit of government is exempt from payment of the fees; and
A nonrefundable fee as specified in Minnesota Statutes, chapter 103I, must be submitted to apply for qualification and examination for licensure as an individual well contractor as specified in part 4725.0475, subpart 3, or certification as a representative for any of the following:
An application for an original or renewal license or registration must be accompanied by a nonrefundable license or registration fee as specified in Minnesota Statutes, chapter 103I.
If a licensee or registrant fails to submit all information required for the renewal of a license or registration or submits the application and information after the required renewal date as specified in part 4725.1300, a late fee as specified in Minnesota Statutes, chapter 103I, must be paid in addition to the fees specified in subpart 3.
A notification fee as specified in Minnesota Statutes, chapter 103I, must be paid by a property owner or the owner's agent for:
each dewatering well constructed, or for a dewatering project comprising five or more dewatering wells; and
each well sealed, or for sealing multiple monitoring wells located on a single property with depths varying by no more than 25 feet that are sealed within 72 hours of the start of construction.
A nonrefundable permit fee as specified in Minnesota Statutes, chapter 103I, must be paid by a property owner or owner's agent:
per site for construction of all monitoring wells, regardless of number, used as leak detection devices at a single motor fuel retail outlet, a single petroleum bulk storage site excluding tank farms, or a single agricultural chemical facility site;
for construction and injection of water by a groundwater thermal exchange device in addition to the notification fee specified in subpart 5;
annually for a dewatering well that is unsealed and under a maintenance permit except that a dewatering project comprising more than five wells shall be issued a single permit for wells recorded on the permit; and
A person must not use a drilling machine unless a nonrefundable fee as specified in Minnesota Statutes, chapter 103I, is paid annually to register the drilling machine.
A person must not use a hoist unless a nonrefundable fee as specified in Minnesota Statutes, chapter 103I, is paid annually to register the hoist.
According to Minnesota Statutes, section 103I.235, a nonrefundable disclosure fee as specified in Minnesota Statutes, chapter 103I, shall be collected.
A nonrefundable fee as specified in Minnesota Statutes, chapter 103I, shall be charged by the commissioner to request a variance from this chapter.
Notification and permit fees for construction and sealing may be paid electronically.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.122
18 SR 1222; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136; L 2015 c 21 art 1 s 109
October 2, 2015
[Repealed, 15 SR 1597]
September 2, 2008
The commissioner shall grant a variance to any provision of this chapter according to the procedures and criteria specified in parts 4717.7000 to 4717.7050.
A person requesting a variance must submit a written request on a form prescribed by the commissioner, along with the nonrefundable fee as required in Minnesota Statutes, chapter 103I.
A variance application for a well or boring located in the jurisdiction of a delegated program must be submitted, along with the fee as specified in Minnesota Statutes, chapter 103I, to the commissioner. The delegated program may require a separate application and fee.
A variance must be applied for and granted prior to commencing the activity for which the variance is requested.
An application submitted without the information required by this part and parts 4717.7000 to 4717.7050 shall be denied 18 months after the date received by the commissioner.
Construction, and the conditions of a granted variance, must be completed within 18 months of variance approval or the variance is void, unless conditions of the variance specify otherwise.
In addition to the information required in part 4717.7000, subpart 2, the applicant must submit to the commissioner, in writing, the following information for a request to vary a construction, repair, or sealing provision related to wells or borings in parts 4725.2010 to 4725.7450:
the location of the well or boring in terms of the township number, range number, section number, three-quarter sections, and the street address if assigned;
the name, address, and telephone number of the contractor doing work, the property owner, and the well owner;
a scaled map showing the location of the well or boring in relation to all property lines, structures, utilities, and contamination sources cited in part 4725.4450;
the depth to water, pumping rate, number of persons served by the well, and a description of the use of the well; and
information on special construction methods, safety measures, or precautions proposed to protect public health, safety, and the environment.
In addition to the information in subparts 1 and 2, a variance request to part 4725.4450 must include:
information on special construction methods or precautions proposed to prevent contamination of the well and groundwater;
a description of the age, design, size, and type of construction of any existing or potential contamination source as specified in part 4725.4450;
any testing, inspection, or certification data and the name and address of the person supplying the data;
a copy of any review of contamination sources done by a local or state unit of government under other applicable regulations.
In addition to the information in subparts 1 and 2, a variance to be placed on a real property deed must include:
A variance may be verbally granted by the commissioner in an emergency where a delay in starting work poses an immediate and significant danger to health or safety.
The person applying for the variance must submit a completed application and fee to the commissioner prior to receiving approval.
The emergency variance shall be void if construction is not started within 72 hours of verbal approval.
All construction and location standards in this chapter, except those specifically modified under the variance, shall apply to wells and borings constructed under an emergency variance.
The commissioner shall not issue an emergency variance to persons who have violated the emergency variance requirements.
MS s 14.05; 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 1597; 17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Except for those persons exempted under Minnesota Statutes, section 103I.205, subdivision 4, paragraph (e), a person must hold a license or registration issued by the commissioner to:
Nothing in this part shall prohibit:
a person from placing a water sampling device including a well pump or pumping equipment in a monitoring well or remedial well to obtain a water sample if the device is immediately removed after the sample is collected;
a plumber or plumbing contractor from installing and servicing a water service pipe according to chapter 4714, from the source of supply;
a water conditioning contractor from installing water conditioning equipment within a building according to chapter 4714;
a limited well/boring contractor from repairing, installing a pump or pumping equipment, or repairing or sealing a well that the limited well/boring contractor is licensed to construct; and
A person performing any of the activities in items A to F must have either a well contractor's license or have a separate limited well/boring contractor license for each of the limited licensure areas listed in items A to F:
limited licensure to construct, repair, modify as specified in subpart 1, item F, or seal a dug well or drive-point well;
limited licensure to install, modify, or repair screens, pitless units or adapters, and casings from the frost line or pitless unit or adapter to the upper termination of the casing;
limited licensure to install a well pump or pumping equipment, or any of the activities in subpart 1, item F, subitems (1) and (2);
limited licensure to seal wells or borings, remove obstructions from a well or boring before sealing, remove or perforate casing before sealing, or other activities to seal a well or boring, except that a drive-point well or dug well contractor may seal a dug well or drive-point well, a dewatering well contractor may seal a dewatering well, an elevator boring contractor may seal an elevator boring, a bored geothermal heat exchanger contractor may seal a bored geothermal heat exchanger, and a monitoring well contractor may seal a monitoring well or environmental bore hole;
limited licensure to construct, repair, seal, or modify as specified in subpart 1, item F, a dewatering well; or
limited licensure to construct, repair, seal, or modify as specified in subpart 1, item F, a bored geothermal heat exchanger.
A person must have an elevator boring contractor's license or a well contractor's license to construct, repair, or seal an elevator boring.
A person must be either licensed as a well contractor or registered as a monitoring well contractor to:
install pumps in monitoring wells.
A person with a limited well/boring contractor license to install a well pump or pumping equipment may install pumps in monitoring wells.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 25 SR 1207; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136; 40 SR 71; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
Anyone applying to be certified as a representative of a licensee or registrant or an individual well contractor must submit to the commissioner a properly completed qualification application. The applicant must submit written documentation of the experience required in part 4725.0650. Written documentation includes, but is not limited to, well or boring construction or sealing records, letters from employers verifying employment, and work reports.
A certified representative and individual well contractor must have honesty and integrity.
The certified representatives, or the individual well contractor, must be named on the license or registration for the licensee or registrant.
The certified representative must:
complete and sign permit applications, notifications, variance applications, construction records, and sealing records; and
be responsible for conducting all operations under the representative's supervision and as delegated by the licensee or registrant according to this chapter and Minnesota Statutes, chapter 103I.
When a certified representative no longer works for the registrant or licensee, the registrant or licensee must inform the commissioner within five days of that fact. If a licensee or registrant has only one certified representative and the representative no longer works for the registrant or licensee, the registrant or licensee must name an acting representative until a representative who meets the requirements in parts 4725.0550 to 4725.1025 is certified by the commissioner. The licensee or registrant may operate with an acting representative for no more than 150 days. The acting representative must notify the commissioner during business hours, a minimum of 24 hours prior to commencing work, of the proposed starting time of each well or boring construction or sealing.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
[Repealed, 15 SR 78]
September 2, 2008
Anyone applying to be certified as a representative of a well contractor or to be an individual well contractor must have four years of experience. A year of experience is a year in which the applicant personally, and under the supervision of a licensed well contractor:
worked for a minimum of 1,000 hours. The applicant's 1,000 hours of experience must include drilling water-supply wells, grouting, sealing wells, repairing wells, installing pumps, disinfecting wells, and completing well construction and sealing records; and
constructed at least one or more multiple cased water-supply wells with an outer casing diameter of ten inches or more and a well depth or cumulative depth of 700 feet or more.
An applicant with experience prior to 2006 must have constructed a minimum of five water-supply wells per year.
An applicant shall be deemed to have one year of experience if the applicant has successfully completed one year of education in well construction practices at an accredited college, university, or postsecondary institution. An applicant shall be deemed to have up to a maximum of two years of experience if the applicant has successfully completed an associate or technical degree in well construction practices at an accredited college, university, or postsecondary institution.
Supervision is not equivalent to personally doing the work.
Anyone applying to be certified as a representative of a monitoring well contractor must meet the requirements in items A to C or meet the requirements in item D.
The applicant must be:
The applicant must have three years of experience. A year of experience is a year in which the applicant worked a minimum of 500 hours in construction, repair, and sealing of monitoring wells, or environmental bore holes including design, field supervision, or actual construction.
The applicant must have designed, field supervised, or actually constructed 50 monitoring wells or environmental bore holes.
The applicant must have three years of experience in construction, repair, and sealing of monitoring wells and environmental bore holes. A year of experience is a year in which the applicant, personally and under the supervision of a registered monitoring well contractor or licensed well contractor, constructed a minimum of 20 monitoring wells or environmental bore holes, of which at least five must be monitoring wells, and constructed, sealed, and repaired monitoring wells or environmental bore holes for 1,000 hours.
Anyone applying to be certified as a representative for a limited well/boring contractor licensed to construct, repair, and seal dug wells and drive-point wells must have three years of experience. A year of experience is a year in which the applicant personally constructed five dug wells or drive-point wells and worked for a minimum of 1,000 hours constructing, repairing, or sealing dug wells or drive-point wells, and installing pumps in dug wells or drive-point wells. An applicant must have gained the experience under a licensed well contractor or a licensed drive-point well or dug well contractor.
Anyone applying to be certified as a representative for a limited well/boring contractor licensed to install or repair well screens or pitless adapters or units and well casing from the pitless device to the upper termination of the well must have two years of experience. A year of experience is a year in which the applicant worked a minimum of 1,000 hours and personally installed or repaired five well screens or pitless units or adapters and well casings from the pitless unit or adapter to the upper termination of the well. The experience must have been gained under the supervision of a licensed well contractor or limited well/boring contractor licensed to install or repair well screens or pitless units or adapters and well casings from the pitless unit or adapter to the upper termination of the well.
Anyone applying to be certified as a representative for a limited well/boring contractor licensed to install a pump or pumping equipment must have two years of experience in pump installation and repair. The applicant must have personally installed 20 pumps. The work must include a minimum of 1,000 hours installing well pumps or pumping equipment.
Anyone applying to be certified as a representative for a limited well/boring contractor licensed to seal wells must have three years of experience. A year of experience is a year in which the applicant:
worked a minimum of 1,000 hours constructing wells, clearing obstructions, removing or perforating well casings, and grouting wells.
The applicant must have gained the experience under a licensed well contractor or limited well/boring sealing contractor.
Anyone applying to be certified as a representative for a limited well/boring contractor licensed to construct, repair, or seal dewatering wells must have two years of experience. A year of experience is a year in which the applicant:
worked a minimum of 500 hours designing, constructing, or field supervising the construction, repair, or sealing of dewatering wells; and
designed, constructed, or field supervised the construction of a minimum of five dewatering wells.
Anyone applying to be certified as a representative for a limited well/boring contractor licensed to construct, repair, or seal bored geothermal heat exchangers must meet the requirements in item A or B.
The applicant must have three years of experience constructing, repairing, and sealing bored geothermal heat exchangers. A year of experience is a year in which the applicant:
worked at least 500 hours designing, constructing, or field supervising the construction, repair, or sealing of bored geothermal heat exchangers.
Experience must be obtained under the supervision of a licensed well contractor or licensed bored geothermal heat exchanger contractor, unless that experience was obtained during directionally drilling bored geothermal heat exchanger systems that were not regulated by this chapter at the time of construction. Experience on unregulated systems counts toward an applicant's experience, whether or not the experience was obtained under the supervision of a licensed well contractor or licensed bored geothermal heat exchanger contractor.
The applicant must:
have three years of experience in well drilling. A year of experience is a year in which the applicant, under the supervision of a licensed well contractor:
be accredited by the International Ground Source Heat Pump Association or certified by the National Ground Water Association as a ground source heat pump driller or installer, or have an equivalent certification as determined by the commissioner based on number of hours of training, subject material, and testing.
Anyone applying to be certified as a representative for an elevator boring contractor licensed to construct, repair, or seal an elevator boring must have two years of experience related to the construction, repair, and sealing of elevator borings. A year of experience is a year in which the applicant designed, supervised, or actually constructed three elevator borings.
If all or part of the experience required in this part was gained by an applicant outside Minnesota, the applicant must provide the commissioner with information satisfactorily demonstrating that the experience was gained constructing, repairing, and sealing wells or borings in geological conditions substantially similar to conditions in Minnesota and in a jurisdiction with certification, licensing, or registration requirements comparable to those in Minnesota.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; L 1992 c 507 s 2; 25 SR 1207; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 15 SR 78]
September 2, 2008
Upon request by the commissioner, the council may conduct oral examinations using a standardized examination developed by the commissioner in consultation with the council. Upon request by the commissioner, the council may also provide recommendations as to the appropriate disciplinary action for representatives, licensees, and registrants found to be in violation of this chapter and Minnesota Statutes, chapter 103I.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 156A.01 to 156A.08
15 SR 78; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
Anyone applying to be a certified representative of a licensee or registrant or as an individual well contractor must pass an examination which may be a combination of written and oral questions as determined by the commissioner with the advice of the Advisory Council on Wells and Borings established by Minnesota Statutes, section 103I.105. The applicant must pass the examination within one year from the date notified by the commissioner that the applicant is qualified to take the examination. An applicant who fails an examination must not retake the examination within two weeks of the failed attempt. An applicant who fails to successfully complete the examination after three attempts must reapply for certification as a representative or licensure as an individual well contractor, according to parts 4725.0550 to 4725.1025, and must not reapply within one year of the third failure to pass the examination. If, upon passing the examination, the applicant is not licensed as an individual well contractor or listed as a certified representative of a licensee or registrant within one year, reapplication as a certified representative or individual well contractor must be made according to parts 4725.0550 to 4725.1025.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A person must apply for licensure or registration on a form provided by the commissioner.
The application must include the name, address, and telephone number of the person applying for licensure or registration and list the name, business address, and telephone number, if different, of all certified representatives of the licensee or registrant who meet the qualifications in parts 4725.0550 to 4725.1025. The licensee or registrant must have at least one certified representative.
The application form must be signed by an officer or other legally authorized agent of the person making application for licensure or registration.
The application for licensure or registration must be accompanied by the nonrefundable licensure or registration fee specified in Minnesota Statutes, chapter 103I.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
[Repealed, 15 SR 78]
September 2, 2008
[Repealed, 15 SR 78]
September 2, 2008
At the time the fee is submitted for initial licensure or registration, or licensure or registration renewal, the licensee or registrant must show proof of holding a corporate surety bond as required by Minnesota Statutes, chapter 103I. The bond must be submitted to the commissioner. One bond is required for each licensee or registrant. If on proof to the commissioner it is shown that multiple licenses or registrations are held by one licensee or registrant, the bond held by that licensee or registrant may cover all licenses and registrations. The licensee or registrant must be named as the principal. The bond must be signed by an official of the company who is legally authorized to represent the company. The bond may be used by the commissioner to compensate persons injured or suffering financial loss because of failure of a licensee or registrant to properly perform the duties under part 4725.0475 and Minnesota Statutes, chapter 103I. The term of the bond must be continuous or concurrent with the term of the license or registration. The penal sum of the bond is noncumulative and is not to be aggregated every year that the bond is in force. The bond must be written by a corporate surety licensed to do business in Minnesota. The corporate surety shall be responsible for providing 30 days' written notice to the commissioner of cancellation of a licensee's or registrant's bond. If a bond is canceled, a licensee or registrant must not perform work requiring the license or registration until the licensee or registrant obtains another bond meeting the requirements of this part. An individual well contractor, as described in Minnesota Statutes, section 103I.525, subdivision 1, paragraph (c), is exempt from the requirements of this part.
MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 18 SR 1222
September 2, 2008
Licenses expire on January 31 of each year and registrations expire on December 31 of each year. Each licensee or registrant shall submit an application for license or registration renewal on forms provided by the commissioner no later than January 31 for licenses and December 31 for registrations. The renewal application must be accompanied by the license and registration fees. A penalty fee, as specified in Minnesota Statutes, chapter 103I, must also be paid if the renewal is submitted after the January 31 license or December 31 registration deadline. At the time of license or registration renewal, the approved continuing education courses completed by the individual well contractor as required by part 4725.1650, or the name(s) of the certified representative(s), must be listed, and the licensee or registrant must provide the bond required under part 4725.1250.
A licensee or registrant who fails to renew a license or registration before the expiration date, and later wishes to renew, must pay all license or registration fees and late fees.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 156A.01 to 156A.08; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
Certification of licensee representatives expires on January 31 of each year and certification of registrant representatives expires on December 31 of each year. Each representative shall submit an application for certification renewal on forms provided by the commissioner no later than January 31 for licensee representatives and December 31 for registrant representatives. At the time of certification renewal, the approved continuing education courses completed by the representative as required by part 4725.1650 must be listed.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
The commissioner may suspend, revoke, or impose limitations or conditions on a license, certification, or registration if the certified representative, individual well contractor, registrant, or licensee:
provides false or fraudulent information verbally, or on renewal forms, construction or sealing reports, water sample reports, or other required reports;
knowingly aids or allows an unlicensed or unregistered person to engage in activities requiring a license or registration under Minnesota Statutes, section 103I.205, subdivision 4;
engages in conduct, in the course of performing work requiring licensure or registration, that is likely to harm the public, or conduct that demonstrates a willful or careless disregard for the health or safety of a property owner or other person;
has been convicted during the previous five years of a felony or gross misdemeanor reasonably related to the business of well or boring construction, repair, or sealing;
fails to pay monetary penalties that are assessed according to an administrative penalty order issued under Minnesota Statutes, chapter 144; or
violates the conditions of a stipulated agreement, variance, order, settlement, compliance agreement, license, registration, certification, notification, or permit.
A suspended or revoked certification, license, or registration along with the current drilling machine and hoist registration decals must be returned to the commissioner when the certification, license, or registration is revoked or suspended.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 156A.01 to 156A.08; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 33 SR 211
September 2, 2008
A person whose certification as a representative, license, or registration has been revoked may not reapply for certification, licensure, or registration within one year of the date of revocation. A person whose certification, license, or registration has been revoked must reapply as required by parts 4725.0550 to 4725.1250.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 156A.01 to 156A.08; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 33 SR 211
September 2, 2008
An individual well contractor or a certified representative of a well contractor or monitoring well contractor must successfully complete six contact hours of continuing education activities annually, of which at least two hours must be obtained from a continuing education program presented or sponsored by the commissioner. A certified representative of a limited well/boring contractor or elevator boring contractor must successfully complete two contact hours of continuing education annually presented or sponsored by the commissioner. A certified representative with multiple limited well/boring or elevator boring certifications need only successfully complete two contact hours of continuing education annually presented or sponsored by the commissioner.
An individual well contractor or certified representative is exempt from the continuing education requirements for one year following the completion of the examination in part 4725.1025.
An individual well contractor or certified representative who fails to complete the continuing education required by this part, must not conduct contracting, or represent a licensee or registrant, for activities regulated by this chapter.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 33 SR 211
September 2, 2008
Continuing education must meet the criteria in items A to E for credit to be given.
Continuing education must be related to wells or borings, drilling technology, groundwater contamination, health aspects of water quality, groundwater monitoring, geology, hydrology, well or boring construction or sealing, water systems or treatment, geothermal systems, dewatering, or elevator borings. Any other continuing education topic must be approved by the commissioner.
The activity must have a specific, written objective that describes expected outcomes for the participant.
The activity must be presented by a person knowledgeable about recent developments in the subject. The person's qualifications must be documented by either specialized training in the subject matter or work experience in the subject area.
The activity must document participation, including but not limited to earned credits and verification of attendance. Program sponsors shall maintain attendance sheets for two years.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
15 SR 78; 33 SR 211; 45 SR 986
April 30, 2021
The Advisory Council on Wells and Borings may review continuing education programs and make recommendations to the commissioner as to the acceptability for continuing education credits for each license or registration category.
MS s 103I.101
15 SR 78
September 2, 2008
A licensee or registrant shall place in a conspicuous location on both sides of each drilling machine or hoist the license or registration number in figures not less than three inches high and 1-1/2 inches wide. The figures must be in a contrasting color to the rest of the machine or hoist. Decals issued by the commissioner designating the year for which the license or registration was issued or renewed must be affixed directly adjacent to and below the license or registration number on each drilling machine or hoist. Contractors using small drilling machines or hoists shall attach their decals on a portable display to be shown at the well or boring site. The decals shall be issued by the commissioner upon licensure or registration and renewal.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 156A.01 to 156A.08; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 33 SR 211
September 2, 2008
Upon licensure or registration, the licensee or registrant must register all drilling machines and hoists and pay a fee for each machine or hoist. Each time the licensee or registrant renews licensure or registration under part 4725.1300, the licensee or registrant must renew each drilling machine and hoist registration and must pay a renewal fee for each drilling machine or hoist. Upon acquiring additional drilling machines or hoists after initial licensure or registration or after renewal of licensure or registration, the licensee or registrant must register the machine or hoist and pay the hoist or drilling machine registration fee. The drilling machine and hoist registrations are concurrent with the license or registration, are not prorated, and expire on January 31 of each year for licensees and December 31 of each year for registrants. Upon receipt of the required fee and information, a drilling machine or hoist registration card shall be issued for identification purposes for each drilling machine and hoist registered by the contractor. The card shall be carried on the drilling machine or hoist at all times where it may be inspected by the commissioner.
The registration card and decals furnished for a drilling machine or hoist are not transferable.
A person must not use a drilling machine or hoist to conduct activities requiring a license or registration under this chapter unless the drilling machine or hoist is registered, displays the licensee's or registrant's license or registration number, and displays current decals.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.122; 156A.01 to 156A.08
15 SR 78; 18 SR 1222; 33 SR 211
October 3, 2013
A person must not construct, or have constructed, a well on another person's property unless a written agreement exists according to Minnesota Statutes, section 103I.205, subdivision 8. The well owner, or other person identified in the agreement as being responsible for the well, has the responsibilities, authorities, and obligations of the property owner specified in this chapter.
A person constructing or sealing a well or boring that is located within a political subdivision with a well and boring program delegated under Minnesota Statutes, chapter 103I, must file a notification with, or obtain a permit from, the delegated program prior to construction or sealing of a well or boring regulated by the delegated program, except that a notification for construction or sealing of a community public water-supply well must be filed with the commissioner.
Notification and permit fees must be paid according to parts 4725.0350 and 4725.1836 and Minnesota Statutes, chapter 103I.
Depths or heights reported on a permit or notification must be measured from the established ground surface.
A notification is not valid until the notification is received by the commissioner between the hours of 8:00 a.m. and 4:30 p.m., Monday through Friday, excluding holidays, except for emergency notifications and permits according to part 4725.1838. A notification received by facsimile after 4:30 p.m. is not valid until the next business day. A permit is not valid until the commissioner has approved the permit. A notification or permit is not valid unless accompanied by the proper fee. Work regulated under a notification or permit must not be done without a valid notification or permit.
A permit or notification is not transferable. Only the licensee or registrant who submits the notification, or the licensee or registrant who was issued the permit, may construct or seal the well or boring.
A well or boring must not be converted to another type of well or boring unless:
the well or boring was constructed by a contractor licensed or registered to construct that type of well or boring, the well or boring complies with the requirements of this chapter for that type of well or boring, and a new notification or permit, and fee if required, is submitted to the commissioner.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211
September 2, 2008
The owner of the property where a water-supply well is to be located, the property owner's agent, a licensed well contractor, or for a drive-point water-supply well, a limited drive-point well or dug well/boring contractor must submit notification of construction of the proposed water-supply well to the commissioner according to this part. This part does not apply to the construction of monitoring wells regulated by part 4725.1830; dewatering wells regulated by part 4725.1825; or drive-point water-supply wells installed by the well owner on the owner's property for residential or agricultural use regulated by part 4725.1849. This part applies to water-supply wells, including wells constructed for the purpose of testing water yields for irrigation, commercial use, residential supply, or a public water system.
A well must not be constructed, deepened through a confining layer, or have casing installed or removed below the frost line until notification is made to the commissioner.
Notification must be made on a form provided by the commissioner, or in a format approved by the commissioner. The notification must be legible, accompanied by the required fee, and signed by the certified representative of the licensee or the owner of the property where the well is located, or the property owner's agent.
The notification must include the following information for each well:
the name, address, and telephone number of the well owner, and property owner if different; and
the township number, range number, section and one quartile, and the property street address if assigned, of the proposed well location.
A new notification must be filed with the commissioner if:
a licensed contractor other than the one listed on the original notification constructs the well; or
the well is completed on property other than that listed on the original notification.
A new fee is not required for a new notification filed under this item.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 18 SR 1222; 25 SR 1207; 33 SR 211
September 2, 2008
This part applies to all dewatering wells as defined in part 4725.0100, subpart 24f, including drive-point wells used for dewatering.
A dewatering well must not be constructed, deepened through a confining layer, have casing installed or removed below the frost line, or completed as an at-grade well until a notification has been made to the commissioner by a dewatering well contractor or well contractor.
The dewatering well contractor or well contractor must submit to the commissioner a dewatering well construction notification on a form provided by the commissioner, or in a format approved by the commissioner. The notification must be legible and signed by the dewatering well contractor or well contractor.
A construction notification must be completed for each dewatering well or dewatering well project including any wells deepened through a confining layer, having casing installed or removed below the frost line, or converted to an at-grade well. The notification must indicate whether the dewatering well, or dewatering well project will affect wells used for potable purposes, and if so, what measures will be taken to provide potable water to persons adversely affected by the dewatering.
The construction notification must include the following information for each well:
the township number, range number, section and one quartile, and the property street address if assigned, of the proposed dewatering well location.
Construction notifications are not transferable. Only the licensee who submitted the notification is authorized to construct the dewatering well or wells.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 15 SR 1474; 17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
This part applies to all monitoring wells, including drive-point wells used as monitoring wells.
A monitoring well must not be constructed, deepened through a confining layer, have casing installed or removed below the frost line, or be converted to an at-grade well until a permit has been issued by the commissioner to the monitoring well contractor, well contractor, or to a limited well screen and pitless adapter and pitless unit contractor for modification to an at-grade well.
A well contractor or monitoring well contractor must submit to the commissioner a permit application on a form provided by the commissioner, or in a format approved by the commissioner. The application must be legible and signed by the monitoring well contractor or well contractor and the property owner or agent.
A permit application must be completed for each monitoring well.
For monitoring wells used as leak detection devices at a single petroleum bulk storage site excluding tank farms, a single agricultural chemical facility site, or a single motor fuel retail outlet, a single permit application may be completed for all wells on a site drilled under a single contract. A site consists of a single continuous piece of property on which the petroleum bulk storage facility or motor fuel retail outlet is located. The site does not include other properties on which monitoring wells are constructed to evaluate a spill or leak associated with the petroleum facility. All proposed monitoring wells on a site must be listed on the permit.
A permit application for a monitoring well owned by a person other than the property owner must include a copy of a written agreement meeting the requirements of Minnesota Statutes, section 103I.205, subdivision 8.
The permit application must include the following information for each well:
the name and registration number of the monitoring well contractor or license number of the well contractor or limited well/boring contractor;
the township number, range number, section and one quartile, and the property street address if assigned, of the proposed monitoring well location; and
Permit applications for monitoring wells constructed through a confining layer or into bedrock must include the following information for each well in addition to that required in item E:
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
This part applies to the construction of a groundwater thermal exchange device (heat pump) with reinjection to an aquifer.
A groundwater thermal exchange device with reinjection to an aquifer must not be constructed until a permit has been issued by the commissioner to the property owner.
The property owner or the property owner's agent must submit to the commissioner a permit application on a form provided by the commissioner, or in a format approved by the commissioner. The application must be legible and must contain:
the name, address, and signature of the owner of the property on which the device will be installed;
the township number, range number, section, and one quartile, and the property street address if assigned, of the proposed device location;
a description of existing wells and any wells proposed to be constructed including the unique well numbers, locations, well depth, diameters of bore holes and casing, depth of casing, grouting methods and materials, and dates of construction;
a description of the heat pump unit including the manufacturer's name, model number, maximum water flow rate in gallons per minute, name of proposed installer, and proposed installation date;
water withdrawal information, pumping schedule with rates in gallons per minute, times and duration, and the total amount of water to be injected into the aquifer;
the specifications for piping including the materials to be used for piping, the flow control valve setting, the provisions for pressure testing the system, and the provisions for disinfection of the completed system; and
The diagram must show that the proposed piping system includes:
a device to provide automatic shutdown of the system if the discharge line pressure is below 15 psi;
The groundwater thermal exchange device must be constructed within 18 months of the date the permit is issued.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211; 40 SR 71
April 1, 2016
This part applies to the sealing of wells, including water supply, remedial, monitoring, temporary monitoring, and dewatering wells, as provided by Minnesota Statutes, sections 103I.231, 103I.301, and 103I.315. This part does not apply to the sealing of borings.
A well must not be sealed until the owner of the property where the well is located, the owner's agent, or a licensee or registrant submits notification of proposed sealing of the well to the commissioner. Notification must be on a form provided by the commissioner or in a format approved by the commissioner. The notification must be legible and must include the following information for each well:
the township number, range number, section and one quartile, and the property street address if assigned; and
identification of a multiple-cased well with an inside casing eight inches or larger in diameter.
A new notification must be filed with the commissioner if a licensee or registrant other than the one listed on the original notification seals the well.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
This part applies to the construction of bored geothermal heat exchangers, including bored geothermal heat exchanger piping installed in a boring for thermal conductivity testing.
A bored geothermal heat exchanger must not be constructed, or have piping installed or removed below the frost line, until a permit has been issued by the commissioner to the well or bored geothermal heat exchanger contractor.
The well contractor or bored geothermal heat exchanger contractor must submit to the commissioner a bored geothermal heat exchanger permit application on a form provided by the commissioner. The application must be legible and signed by the well contractor or bored geothermal heat exchanger contractor and the property owner or property owner's agent. The application must include:
the name and license number of the well contractor or bored geothermal heat exchanger contractor;
the name and address of the owner of the property on which the bored geothermal heat exchanger will be installed;
the township number, range number, section and one quartile, and the property street address if assigned, of the proposed bored geothermal heat exchanger;
a plan diagram showing the location of the bored geothermal heat exchanger borings, property lines, and structures on the property;
the number, diameter, and depth of all bore holes drilled to install the bored geothermal heat exchanger piping;
The well contractor or bored geothermal heat exchanger contractor must inform the commissioner of the proposed construction starting time 24 hours before starting construction of bored geothermal heat exchanger borings. The information must be reported by telephone, by facsimile, electronically, or in person between 8:00 a.m. and 4:30 p.m., Monday through Friday, excluding holidays.
The bored geothermal heat exchanger must be constructed within 18 months of the date the permit is issued.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 25 SR 1207; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136; 45 SR 986
April 30, 2021
This part applies to an excavation or hole for installation of an elevator boring.
An elevator boring must not be constructed until a permit has been issued by the commissioner to the elevator boring contractor or well contractor.
An elevator boring contractor or well contractor must submit to the commissioner an elevator boring permit application on a form provided by the commissioner, or in a format approved by the commissioner. The application must be legible and signed by the elevator boring contractor or well contractor.
The permit must include the following information for each elevator boring:
the township number, range number, section and one quartile, and the property street address if assigned, of the proposed boring location; and
Permit applications for elevator borings constructed through a confining layer must include the following information in addition to that required in item C:
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
The fees specified in Minnesota Statutes, chapter 103I, must accompany all notifications and permit applications. Notification or permit fees may be paid electronically and the permit requests or notifications may be submitted by facsimile. A notification or permit is not valid if payment by check is returned for nonsufficient funds, or electronic payment is refused by the financial institution. Notification and permit application fees shall not be refunded, except that a water-supply well notification fee may be refunded to the person who paid the fee if drilling has not taken place, and a written request for refund is received by the commissioner within 18 months of receipt of the fee.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
A permit or notification is not required for installation of a pump, pumping equipment, pitless unit, pitless adapter, screen, or the repair of an existing well or boring if the repair does not involve deepening the well or boring through a confining layer or having casing installed or removed below the frost line.
MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 33 SR 211
September 2, 2008
Notifications and applications for permits may be verbally reported under emergency conditions for construction of water-supply wells, elevator borings, monitoring wells, and dewatering wells, except for monitoring wells and dewatering wells constructed through a confining layer and for at-grade monitoring wells. Emergency conditions are exceptional circumstances where a delay in starting construction poses an immediate and significant danger to health or safety and there is no time for prior notification or obtaining the required permit.
Exceptional circumstances include, but are not limited to, cases where well failure will leave livestock or persons without drinking water, where inaction presents an imminent threat to contamination of the well, boring, or groundwater, where delay will result in collapse or damage to the well or boring, where delay will result in the endangerment of health or safety such as in an unstable excavation, or where such construction is court ordered.
If emergency conditions affecting construction of a water-supply well, or dewatering well occur during normal business hours, the property owner, the property owner's agent or a licensed contractor may verbally provide to an authorized representative of the commissioner the information required for notification under part 4725.1820 or 4725.1825. If emergency conditions affecting construction of a monitoring well or elevator boring occur during normal business hours, the contractor may verbally provide the information required for permits under part 4725.1830 or 4725.1835, whichever is applicable, to an authorized representative of the commissioner.
If emergency conditions occur after business hours or on a nonbusiness day, construction of a water-supply well, monitoring well, dewatering well, or elevator boring may begin if the property owner, property owner's agent, or contractor, as required in item A, telephones the Minnesota Department of Health and leaves a message on the answering service reporting the applicable information required in part 4725.1820, 4725.1825, 4725.1830, or 4725.1835.
A written notification or written permit application and the applicable fees must be received by the commissioner within five working days after emergency notification of the start of construction of a water-supply well or dewatering well, or within five working days after the start of construction under an emergency permit for a monitoring well or elevator boring. The property owner, the property owner's agent, or a licensed or registered contractor is responsible for submitting a written notification or permit and fee.
The emergency notification or permit shall be void if construction is not started within 72 hours of verbal reporting.
All construction and location standards in this chapter shall apply to wells and borings constructed under emergency conditions.
The commissioner shall not issue emergency permits to, or accept emergency notifications from, contractors who violate the emergency notification or permit requirements.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
15 SR 78; 33 SR 211
September 2, 2008
If a water-supply well, monitoring well, dewatering well, bored geothermal heat exchanger, or elevator boring for which a notification or permit has been filed is unsuccessful, a new well or boring may be constructed for the same owner on the same property within 18 months of notification or permit approval, without submitting a new construction fee, notification, or permit application if:
the construction and depth of the new well or boring is not substantially different from the initial well or boring;
the person installing the well or boring submits an amended well and boring construction record; and
the unsuccessful well or boring is sealed according to this chapter and a sealing record is submitted.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
15 SR 78; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136
October 10, 2014
The commissioner shall review a permit application upon submission. A permit shall be issued if the application is complete and is in compliance with this chapter.
MS s 103I.101
15 SR 78
September 2, 2008
The commissioner may deny a permit application or revoke a permit for construction of a monitoring well, groundwater thermal exchange device, bored geothermal heat exchanger, or elevator boring if:
the person constructing the well or boring is not licensed or registered according to this chapter;
information submitted in the permit application is determined to be incomplete, incorrect, omitted, false, or misrepresented;
the well or boring would be constructed into or through contaminated soil or groundwater, and construction or use of the well or boring would result in contamination of a well or boring, allow contamination to spread, or would adversely affect groundwater remediation; or
pumping from the well or boring would intercept groundwater contamination and construction or use of the well or boring would result in contamination of a well or boring, allow contamination to spread, or would adversely affect groundwater remediation.
The commissioner shall give the applicant or permit holder written notice of the permit application denial or permit revocation. The notice shall state the reason for denial or revocation. A denied permit application or revoked permit may be revised or corrected and resubmitted to the commissioner for reconsideration.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
15 SR 78; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136
October 10, 2014
Annual maintenance permits are required for monitoring wells and dewatering wells that were constructed after January 1, 1990, and are not permanently sealed within 14 months of construction.
Annual maintenance permits are required for wells, including monitoring wells, dewatering wells, and water-supply wells, that are not in use and not sealed.
The owner of the property where the well is located must submit to the commissioner a maintenance permit application on a form provided by the commissioner. The application must be legible, accompanied by the correct fee, and signed by the property owner where the well is located. The permit application shall include the following information for each well:
the Minnesota unique well number. If the unique number is not known, the depth, diameter, and construction of the well must be reported.
The commissioner shall review a permit application upon submission. A permit shall be issued if the application is complete and is in compliance with this chapter. A permit shall not be issued for a well that is required to be sealed by this chapter or Minnesota Statutes, section 103I.301.
The conditions in this subpart apply to maintenance permits.
Maintenance permits are not transferable. If ownership of the property changes, an application must be made for a new maintenance permit.
A maintenance permit does not allow construction or repair that would require notification or a permit according to this chapter.
The commissioner may deny a permit application or revoke a permit for violation of this chapter. The commissioner shall give the applicant or permit holder written notice of the permit application denial or permit revocation. The notice shall state the reason for denial or revocation.
An annual well maintenance permit is required for an unsealed dewatering well, monitoring well, or water-supply well that is not in use or that is inoperable. The owner of the property on which such a well is located must submit the annual permit fee along with the permit application, or have the well sealed.
The provisions in items A to C apply to monitoring wells constructed after January 1, 1990.
The owner of property on which an unsealed monitoring well is located must obtain a maintenance permit starting 14 months after construction of the well and must pay the required permit fee. The permit must be renewed annually until the well is sealed.
A maintenance permit application must be completed for each monitoring well. However, a single permit application may be completed for monitoring wells used as leak detection devices at a petroleum bulk storage site or a motor fuel retail outlet. The permit must list each well and include the well location and unique well number. A site or outlet consists of a single continuous piece of property on which the petroleum bulk storage or retail motor fuel outlet is located. The site does not include other properties on which monitoring wells are constructed to evaluate a spill or leak associated with the petroleum facility.
Monitoring wells that are inoperable or not in use, or for which no maintenance permit has been obtained 14 months after construction, must be permanently sealed.
The conditions in items A to C apply to dewatering wells constructed after January 1, 1990.
No later than 14 months after construction of a dewatering well, the owner of the property on which a dewatering well is located must obtain a maintenance permit for an unsealed dewatering well and must pay the required permit fee. The permit must be renewed annually for wells that are in use.
A maintenance permit for a dewatering project of ten or more dewatering wells must list each well and include the well location and unique well number.
Dewatering wells that are inoperable or not in use, or for which no maintenance permit has been obtained, must be permanently sealed.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
15 SR 78; 17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
This part applies to drive-point water-supply wells constructed by an individual on property that is owned or leased by the individual and that is used for agricultural purposes or as the individual's place of residence. The construction, maintenance, and repair of the drive-point well must comply with parts 4725.2010 to 4725.5650. This part does not grant authority for the individual to seal the drive-point well. This part does not apply to drive-point water-supply wells constructed by a well contractor, drive-point wells installed for purposes other than water supply, or to wells other than drive-point wells installed by the property owner or lessee.
Written notification of construction of a drive-point well installed by a property owner must be filed with the commissioner within ten days after completion of the well. The owner of the drive-point well must provide the following information on a notification form provided by the commissioner:
the name, address, and telephone number of the drive-point well owner and property owner, if different;
A person who sells drive-point well screens at retail must provide each buyer with a copy of the notification form and informational materials provided by the department.
The commissioner shall provide copies of the drive-point notification form and information about well regulations to retail sellers of drive-point well screens.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
15 SR 78; 33 SR 211
September 2, 2008
[Repealed, 15 SR 78]
September 2, 2008
A licensee, registrant, or property owner or lessee for a well constructed according to Minnesota Statutes, section 103I.205, subdivision 4, paragraph (e), clause (1), must submit an accurate, verified, legible written record of well or boring construction or sealing on forms provided by the commissioner, or in a format approved by the commissioner, containing the information in subparts 2 to 4 within 30 days after completion of the work. A written construction record is not required for any well or boring sealed within 30 days of the time construction began and for which a sealing record is submitted.
A new or amended record is required if a notification or permit is required under parts 4725.1820 to 4725.1838.
The licensee or registrant must furnish the owner or owner's agent one copy, retain one copy, and submit the remaining copies to the commissioner, except that where a community health board has been delegated authority under Minnesota Statutes, section 103I.111, the remaining copies must be submitted to the delegated program.
A single record may be used to report more than one temporary monitoring well, dewatering well, or environmental bore hole if all the wells or borings on the record are located on a continuous parcel of property, the well or boring depths do not vary by more than 25 feet, and the wells or borings terminate in the same geologic formation. All wells or borings must be of the same type. A map must be attached to the record containing multiple wells or borings, showing all well or boring unique numbers and locations with distances and directions in relation to recognizable landmarks.
Construction records for wells and borings must be completed on a form provided by the commissioner and must contain the information in subpart 3, items A to F, and the following information:
wellhead description including pitless adapter manufacturer and model if installed, and type of casing protection if installed;
description of the geological materials penetrated by the well or boring using terms in subpart 4;
for bored geothermal heat exchangers, the following additional information must be provided either on the commissioner's form or on an accompanying document:
the location where each pipe loop enters the drilled hole must be shown on a scaled map with angles and directions from surveyed property corners, a permanent benchmark, or the corner of a permanent structure;
for bored geothermal heat exchanger piping installed using directional drilling technology, a scaled map showing the location of the entire length of each pipe loop and a cross-sectional profile showing the depth profile of the pipe loops;
GPS coordinates for the location where each pipe loop enters the drilled hole or GPS coordinates marking the corners or perimeter of the loop field;
A sealing record must be submitted for all wells and borings sealed.
The sealing record must contain the following information:
name, license or registration number of the contractor doing the work, name of the driller performing the work, and the signature of the certified representative;
the county, township, range, section and three quartiles, and the property street address, if assigned, of the well or boring;
a map showing the well or boring location with distances and directions in relation to recognizable landmarks;
for records submitted under subpart 1, item C, the location data at the center of the project, the number of wells or borings included on the record, and a sketch map showing the location of each well or boring;
a description of the geological materials penetrated by the well or boring or a description of material penetrated by the nearest well or boring for which records are available, using terms in subpart 4;
The geological materials penetrated in drilling a well or boring must be reported. The person completing the record must include the rock and unconsolidated material types, color, and relative hardness. The grain size must be reported for unconsolidated materials and may be based on field observation without technical size measurement. Geological materials must be described using the terms in items A and B, terms contained in the Dictionary of Geological Terms, Third Revision, by the American Geological Institute, or ASTM Standard D2487-00.
Unconsolidated materials:
Material | Diameter | Diameter | Screen Slot No. | |
Millimeters | Inches | From | To | |
(1) Clay | Up to 0.005 | Up to 0.0002 | - | - |
(2) Silt | 0.005-0.062 | 0.0002-0.0025 | - | - |
(3) Fine Sand | 0.062-0.250 | 0.0025-0.0100 | 2 | 10 |
(4) Medium Sand | 0.250-0.500 | 0.0100-0.0200 | 10 | 20 |
(5) Coarse Sand | 0.500-1.000 | 0.0200-0.0400 | 20 | 40 |
(6) Very Coarse Sand | 1.000-2.000 | 0.0400-0.0800 | 40 | 80 |
(7) Fine Gravel | 2.000-4.000 | 0.0800-0.1600 | 80 | 160 |
(8) Coarse Gravel | 4.000-62.500 | 0.1600-2.5000 | 160 and larger | |
(9) Cobbles | 62.500-250.000 | 2.5000-10.0000 | - | - |
Rock:
basalt, which is a very fine-grained, dark igneous rock, commonly black, dark gray, or dark red-brown in which the mineral grains cannot be distinguished with the unaided eye;
dolomite or dolostone, which is a sedimentary rock composed primarily of the mineral dolomite (calcium-magnesium carbonate), which effervesces weakly in dilute hydrochloric acid;
gabbro, which is a dark-colored, basic intrusive igneous rock comprised principally of basic plagioclase (commonly labradorite or bytownite) and clinopyroxene (augite);
gneiss, which is a foliated rock formed by regional metamorphism, in which bands or lenticles of granular minerals alternate with bands or lenticles in which minerals having flaky or elongate prismatic habits predominate;
granite, which is a plutonic rock in which quartz constitutes ten to 50 percent of the felsic components and in which the alkali feldspar/total feldspar ratio is generally restricted to the range of 65 to 90 percent;
iron formation, which is a chemical sedimentary rock, typically thin bedded and/or finely laminated, containing at least 15 percent iron of sedimentary origin, and commonly but not necessarily containing layers of chert;
limestone, which is a sedimentary rock composed primarily of the mineral calcite (calcium carbonate), which effervesces freely in dilute hydrochloric acid;
metavolcanic (rock), which is a volcanic rock that shows evidence of having been subjected to metamorphism;
quartzite, which is a very hard sandstone, consisting chiefly of quartz grains that have been so completely and solidly cemented with secondary silica that the rock breaks across or through the grains rather than around them, or a granoblastic metamorphic rock consisting mainly of quartz, which is formed by recrystallization of sandstone or chert by metamorphism;
sandstone, which is a sedimentary rock consisting of cemented or otherwise compacted sediment composed predominantly of sand-sized particles generally of quartz;
schist, which is a strongly foliated crystalline rock, formed by dynamic metamorphism, that can be readily split into thin flakes or slabs due to the well-developed parallelism of more than 50 percent of the minerals;
slate, which is a fine-grained, hard, dark-colored metamorphic rock derived from shale, which typically is gray and which splits readily into flat pieces; and
volcanic (rock), which is a generally finely crystalline or glassy igneous rock resulting from volcanic action at or near the earth's surface.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; L 2015 c 21 art 1 s 109; 45 SR 986
April 30, 2021
A licensee or registrant must submit cutting samples as specified in this part when the commissioner determines that samples are needed to provide subsurface geological and hydrological information for the state water information system.
The commissioner shall notify licensees and registrants of the areas from which cutting samples are required and provide licensees and registrants operating within the areas with maps or lists indicating counties, townships, sections, or other designated areas where cutting samples are required.
Licensees and registrants so notified and supplied shall collect cutting samples during the course of drilling in the designated areas according to the requirements specified. Licensees or registrants not supplied with sample collecting materials but who drill in an area designated for sampling shall notify the commissioner. Licensees or registrants shall collect the cutting samples in a manner representative of the materials encountered. Samples must be taken at five-foot intervals and at every change in geological material type. The cuttings must be placed in the sample bags provided, which shall have an attached tag on which the unique number, owner's name, location, and sample depth must be written.
Licensees or registrants shall notify the commissioner within 30 days of completion of work, so that the cutting samples can be collected. Until collected, the licensee or registrant shall store the samples protected from weather and disturbance and segregated by unique number and depth interval.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
The general construction and use requirements specified in parts 4725.2010 to 4725.3875 apply to all wells and borings except exploratory borings regulated under chapter 4727. The additional requirements or exemptions in parts 4725.4050 to 4725.6050 apply to water-supply wells. The additional requirements or exemptions in part 4725.6150 apply to dewatering wells. The additional requirements or exemptions in parts 4725.6450 to 4725.6850 apply to monitoring wells and cased environmental bore holes. The additional requirements or exemptions in part 4725.7050 apply to bored geothermal heat exchangers. The additional requirements or exemptions in part 4725.7250 apply to elevator borings. The additional requirements or exemptions in part 4725.7450 apply to environmental bore holes.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136
October 10, 2014
A well or boring must not be constructed to interconnect aquifers separated by a confining layer or interconnect an unconsolidated aquifer and a bedrock aquifer.
A well or boring must not have open bore hole, gravel pack, or screen extending through more than:
50 percent of the confining layer.
The commissioner may establish less stringent standards than identified in this subpart where protective conditions exist or unique characteristics of the confining layer exist, including low permeability overlying materials, favorable groundwater gradients, the presence of fractures or permeable horizons in the confining layer, or reduced contaminant loading in recharge areas. The areas subject to less stringent standards under this provision will be designated on a map published by the commissioner, along with the standards that do apply to those areas.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
A well or boring must not be used for disposal or injection of surface water, groundwater, or any other liquid, gas, or chemical, except for groundwater thermal exchange devices, bored geothermal heat exchangers, drilling fluids, vertical turbine prelubrication water, treatment chemicals, priming water, water used for hydrofracturing, and water used for disinfection according to parts 4725.1831, 4725.1833, 4725.2950, 4725.3250, 4725.3725, 4725.5050, 4725.5475, and 4725.5550. This does not prohibit the injection of air for drilling, development, or sparging.
Water used to cool parts of engines, air compressors or other equipment, or air conditioning equipment must not be returned to a well or any part of a potable water system except if permitted as a groundwater thermal exchange device under part 4725.1831 and Minnesota Statutes, section 103I.621.
A well may be used for the injection of water to conduct a slug test if the injected water was originally taken from that well or is potable water.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
The minimum isolation distances in item A or B must be maintained during construction, repair, or sealing of a well or boring, and installation of a pipe with flammable or volatile gas, an overhead or underground electric transmission, distribution, service, supply, feeder, branch, or conductor line hereafter called "electric line" or "line," or a liquid propane tank. The distances are measured horizontally from the closest part of the well or boring to the closest part of the pipe, tank, or line; or closest part of the vertical projection on the earth of an overhead or buried pipe, tank, or line. The minimum isolation distance between a well or boring and a pipe with flammable or volatile gas, an electric line, or a liquid propane tank is:
five feet if:
the person constructing the well or boring, or the person installing the pipe, line, or tank, marks the well or boring with a permanent sign warning of the location of the electric line, liquid propane tank, or gas pipe; and
during construction or sealing of the well or boring:
the electric line has been de-energized and visibly grounded, or insulating barriers not a part of, or an attachment to, the equipment or machinery have been erected to prevent physical contact with the line during well or boring construction; and
Subpart 1 does not apply to:
a television, fiber optic, or other low voltage electric line with a voltage less than 50 volts;
a temporary liquid propane tank used during the construction, repair, or sealing of a well or boring;
an overhead electric line when the repairing or sealing of a well or boring does not involve the use of a drilling machine or hoist;
a buried electric line or buried gas pipe when the repairing or sealing of a well or boring does not involve excavation; or
a buried electric line or gas pipe when a nonvertical bored geothermal heat exchanger boring is installed using directional drilling technology, provided that:
the notice of excavation and location of buried utilities are completed according to Minnesota Statutes, chapter 216D; and
the point where the drill bit penetrates the ground surface complies with the isolation distances in subpart 1.
The requirements of this part are minimum standards and do not exempt persons from more restrictive requirements of the Occupational Safety and Health Administration.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
A well or boring must not be located within a building, and a building must not be constructed to enclose a well or boring, unless the building (well house) meets the requirements of this part. Environmental bore holes and monitoring wells are exempt from this subpart if sealed within 72 hours of the time construction begins on the well or boring.
A building (well house) containing a well or boring must:
have adequate access for a drilling machine and hoist to construct, maintain, repair, and seal the well or boring;
be constructed at or above the established ground surface. If a floor drain is installed, it must discharge to the established ground surface, a gravel pocket, or a sewer constructed to prevent backup of sewage within 50 feet of the well or boring;
not be used to store materials or chemicals that may cause contamination of the well, boring, or groundwater, including fertilizers, pesticides, petroleum products, paints, and cleaning solvents;
be constructed according to this part exclusively to contain and protect the well, boring, pump, and water treatment equipment and water treatment chemicals; no other uses of the building are permitted; and
not be contained in, or part of, another building, except that a well house may be constructed with not more than one wall in common with another building. The common wall must not allow access to, or be open to, the well house.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
A minimum horizontal isolation distance of three feet must be maintained between a well or boring and the farthest exterior projection of a building, including the walls, roofs, decks, overhangs, and other permanent structures unless the well or boring is located in a building constructed according to part 4725.2175. A building, deck, or other permanent structure, except a well house, must not be built to enclose a well or boring. The well or boring must be accessible for repair and sealing. Environmental bore holes and monitoring wells are exempt from this subpart if sealed within 72 hours of the time construction begins on the well or boring. A directionally drilled bored geothermal heat exchanger is exempt from this provision if constructed according to part 4725.7050, subpart 3.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
Permanent casing installed in a well or boring must be:
stainless steel casing as specified in part 4725.6650 when used for a monitoring well, environmental bore hole, or remedial well;
All casing couplings and casing joints must be watertight throughout their lengths. Casing must not have holes, cracks, or separations.
All casing joints must be watertight, with threaded, welded, or solvent welded joints, and comply with the standards in part 4725.2350, 4725.2550, or 4725.6650.
Threaded joints must have recessed couplings, reamed and drifted couplings, or other couplings that match the design, taper, and thread type of the casing. Thread must not be exposed on the pipe when the casing is joined.
Welded casing, except where an approved welding coupling is used, must have beveled joints. The weld must extend the full circumference of the casing and must completely fill the bevel.
Welding couplings must be made of material equivalent to the casing. The upper and lower welds must extend the full circumference of the casing, and completely fill the gap between the coupling and casing. Welding the casing to the inside of the coupling is prohibited.
Casing used in the permanent construction of a well or boring must be new casing produced to the specifications of this part. Casing salvaged from the same type of well or boring within 120 days of installation is acceptable for reuse if it meets the specifications for new casing. A potable water well must be constructed with new casing or casing salvaged from a potable water well.
Steel and plastic permanent casing except flush-threaded PVC and stainless steel casing must be marked by the manufacturer in accordance with casing specifications in parts 4725.2350 to 4725.2550. Markings must be rolled, stamped, or stenciled by the manufacturer.
Casing rejected by the manufacturer must not be used. The commissioner may require that casing be submitted to an independent testing agency to evaluate if it meets or exceeds specifications when the casing:
The commissioner shall reject casing for use in a well or boring if:
the lot of casing contains defective lengths, including casing with girth-welded joints, or welded patches, or the lot has more than five percent of the casings with lengths less than five feet.
Casing installed temporarily during drilling is not required to meet the specifications for casing in this part except subparts 2, 7, and 16 and part 4725.2350, 4725.2550, or 4725.6650, but must be of sufficient strength to withstand the structural load imposed by conditions both inside and outside the well or boring, and free of oil or other contaminants. The casing must be removed on completion of the well or boring.
The inside diameter of an outer casing must be at least 3.0 inches larger than the outside diameter of the inner casing, couplings, or bell-end, whichever is larger, except that the inside diameter of an outer casing must be at least 3.5 inches larger than the outside diameter of the inner casing, couplings, or bell end, whichever is larger, for inner casings deeper than 100 feet and larger than 12 inches inside diameter. The annular space between an inner casing and an outer casing must be grouted for its entire length by pumping neat-cement grout or cement-sand grout through a tremie pipe or through the casing as specified in part 4725.3050. The inner casing must extend above the established ground surface at least 12 inches.
A permanent outer steel casing installed in unconsolidated materials is not required to meet the requirements of this part except subparts 2, 9, and 17, or the material specifications for casing in part 4725.2350 if the casing is of sufficient strength to withstand the structural load imposed by conditions both inside and outside the well or boring, the casing is free of oil or other contaminants, an inner casing meeting the requirements of this chapter is installed, and the annular space between the casings is filled with neat-cement grout, or cement-sand grout. The outer casing must be installed in accordance with part 4725.3050, subpart 3 or 5.
The inside diameter of a permanent casing must not be less than two inches for a well or boring greater than 50 feet in depth.
A casing or casing extension must extend vertically at least 12 inches above the established ground surface, the floor of a building (well house) as specified in part 4725.2175, or a concrete slab, except that the casing for a hand pump may terminate a minimum of six inches above a concrete slab in accordance with part 4725.3250, item A, if the concrete slab is at least six inches above the established ground surface. The established ground surface, slab, or floor immediately adjacent to the casing must be graded to divert water away from the casing. Termination of the top of the casing below the established ground surface, such as in a well pit, is prohibited except that an outer casing may terminate immediately below a pitless adapter installed on an inner casing.
Except for inner and outer casings installed in accordance with subpart 8, multiple casings must not be installed in a single bore hole.
A casing must maintain the same inside diameter throughout the length of the casing, except that a larger diameter pitless unit may be installed.
A drive shoe must be installed on driven casing except for a drive-point casing, temporary casing, or outer casing that has a neat-cement or cement-sand grouted inner casing. The drive shoe must:
Until a well or boring is completed and a permanent cap or cover installed, the installer must temporarily cap or cover the bore hole, casing, and annular space of a well or boring when not actively working on the well or boring, in accordance with subpart 17, or install a weatherproof, tamper-proof cover. An overlapping steel plate is permitted. Tape, pails, loose plastic, or similar covers are not permitted.
A permanent watertight and vermin-proof cap or cover must be installed on the inner casing of a well or boring. The cap or cover must be constructed of metal or plastic materials having a thickness comparable to the casing requirements specified in subpart 1. The cap or cover must consist of:
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
Steel casing used in the permanent construction of a well or boring must be new casing produced to:
API Standard 5L-04.
Steel casing must have the minimum weights and thicknesses specified in the table in subpart 2 subject to the tolerances in the specifications in this subpart.
Size in Inches | Plain End | Wgt. Lbs. Per Ft. Thrds. & Cplgs.* | Thrds. R&D Cplgs. | Thickness in Inches | |
S | 1 | 1.68 | 1.68 | 1.70 | .133 |
c | 1-1/4 | 2.27 | 2.28 | 2.30 | .140 |
h | 1-1/2 | 2.72 | 2.73 | 2.75 | .145 |
e | 2 | 3.65 | 3.68 | 3.75 | .154 |
d | 2-1/2 | 5.79 | 5.82 | 5.90 | .203 |
u | 3 | 7.58 | 7.62 | 7.70 | .216 |
l | 3-1/2 | 9.11 | 9.20 | 9.25 | .226 |
e | 4 | 10.79 | 10.89 | 11.00 | .237 |
5 | 14.62 | 14.81 | 15.00 | .258 | |
4 | 6 | 18.97 | 19.18 | 19.45 | .280 |
0 | 8 | 28.55 | 29.35 | .322 | |
10 | 40.48 | 41.85 | .365 | ||
S | 12 | 49.56 | 51.15 | .375 | |
t | 14 | 54.57 | 57.00 | .375 | |
a | 16 | 62.58 | 65.30 | .375 | |
n | 18 | 70.59 | 73.00 | .375 | |
d | 20 | 78.60 | 81.00 | .375 | |
a | 22 | 86.61 | .375 | ||
r | 24 | 94.62 | .375 | ||
d | 26 | 102.63 | .375 | ||
30 | 118.65 | .375 | |||
W | 32 | 126.66 | .375 | ||
g | 34 | 134.67 | .375 | ||
t | 36 | 142.68 | .375 |
* Nominal weight based on length of 20 feet including coupling.
Steel casing up to ten inches in diameter must be Schedule 40. Larger diameter casing must be standard weight.
Diameter-Inches | Couplings | |||
External | Internal | Thrds. per Inch | Minimum External Diameter Inches | Minimum Length Inches |
1.315 | 1.049 | 11-1/2 | 1.576 | 2-5/8 |
1.660 | 1.380 | 11-1/2 | 1.900 | 2-3/4 |
1.900 | 1.610 | 11-1/2 | 2.200 | 2-3/4 |
2.375 | 2.067 | 11-1/2 | 2.750 | 2-7/8 |
2.875 | 2.469 | 8 | 3.250 | 3-15/16 |
3.500 | 3.068 | 8 | 4.000 | 4-1/16 |
4.000 | 3.548 | 8 | 4.625 | 4-3/16 |
4.500 | 4.026 | 8 | 5.200 | 4-5/16 |
5.563 | 5.047 | 8 | 6.296 | 4-1/2 |
6.625 | 6.065 | 8 | 7.390 | 4-11/16 |
8.625 | 7.981 | 8 | 9.625 | 5-1/16 |
10.750 | 10.020 | 8 | 11.750 | 5-9/16 |
12.750 | 12.000 | 8 | 14.000 | 5-15/16 |
14.000 | 13.250 | 8 | 15.000 | 6-3/8 |
16.000 | 15.250 | 8 | 17.000 | 6-3/4 |
18.000 | 17.250 | 8 | 19.000 | 7-1/8 |
20.000 | 19.250 | 8 | 21.000 | 7-5/8 |
22.000 | 21.250 | |||
24.000 | 23.250 | |||
26.000 | 25.250 | |||
30.000 | 29.250 | |||
32.000 | 31.250 | |||
34.000 | 33.250 | |||
36.000 | 35.250 |
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 33 SR 211]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Plastic casing and couplings used in the permanent construction of a well or boring must:
meet ASTM Standard F480-02, except that flush threaded polyvinyl chloride casing must not be used except for a monitoring well or environmental bore hole; and
withstand internal pressures of 200 pounds per square inch (psi).
Standard dimension ratios (SDR) and water pressure ratings (PR) at 23 degrees Celsius (73 degrees Fahrenheit) for nonthreaded polyvinyl chloride (PVC) and acrylonitrile-butadiene-styrene (ABS) plastic casing equal to or greater than 200 psi are as follows:
pressure rating of PVC casing materials:
SDR | PVC 1120 | PVC 1220 | PVC 2112 | PVC 2116 | PVC 2120 |
13.5 | 315 psi | 315 psi | 200 psi | 250 psi | 315 psi |
17 | 250 psi | 250 psi | - | 200 psi | 250 psi |
21 | 200 psi | 200 psi | - | - | 200 psi |
pressure rating of ABS casing materials:
SDR | ABS 1316 | ABS 2112 |
13.5 | 250 psi | 200 psi |
17 | 200 psi | - |
The sources of the pressure rating in item B are the American Society for Testing and Materials Standard D2241-04a "Standard Specifications for Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series)" Table XI.I Standard Thermoplastic Pipe Dimension Ratios (SDR) and Water Pressure Rating (PR) at 73 degrees Fahrenheit (23 degrees Celsius) for Nonthreaded Plastic Pipe; and Standard D2282-99e "Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)," Table XI.I Standard Plastic Pipe Dimension Ratios (SDR) and Water Pressure Ratings (PR) at 73 degrees Fahrenheit (23 degrees Celsius) for Nonthreaded ABS Plastic Pipe.
In addition to the plastic couplings approved under subpart 1, the following fittings and couplings may be used to connect a steel pitless unit or screen to plastic casing:
fittings or couplings with socket dimensions meeting the requirements of ASTM Standard F480-02, Table 3 and having a water pressure rating of at least 200 psi;
Schedule 40, slip x internal thread fittings, four-inch and smaller meeting the requirements of ASTM D2466-02; or
Schedule 40, slip x internal thread fittings and slip x external thread fittings, five-inch diameter meeting the requirements of ASTM D2466-02.
All plastic casings, couplings, components, and related joining materials including solvents, cements, or primers used in the construction of a well or boring must conform with the requirements of ANSI/NSF Standard 61-2003e or the health effects portion of ANSI/NSF Standard 14-2003 and be tested as conforming by an agency certified by the ANSI. Conformance to the ANSI/NSF standard must be coded, stamped, or marked on the casings, couplings, components, and related joining materials including solvents, cements, or primers.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
When preparing to install plastic casing, a person must:
inspect casing and couplings carefully for cuts, gouges, deep scratches, damaged ends, and other major imperfections and not use any plastic casing or coupling having such defects or imperfections;
use solvent cement meeting the requirements of the specifications for the plastic that will be used;
use plastic couplings with molded or formed threads and thread lubricants suitable for the plastic material that will be used; and
use a coupling appropriate for the specific transition intended when a nonplastic screen is attached to a plastic casing.
When cutting plastic casing, casing ends must be cut square using fine-tooth blades with little or no set or a plastic pipe cutter equipped with extra wide rollers and thin cutting wheels. Standard steel pipe or tubing cutters must not be used for cutting plastic casing.
All dirt, dust, moisture, and burrs must be cleaned from casing ends and couplings using chemical or mechanical cleaners suitable for the particular plastic material. All burrs must be removed.
An even coat of cement must be applied to the inside of the couplings to cover the distance of the joining surface only. An even coat of solvent cement must then be applied to the outside of the casing being joined to a distance equal to the depth of the casing coupling socket.
When assembling plastic casing, a person must:
turn the casing to evenly distribute the solvent cement while inserting the coupling into the coupling socket;
A person must not drill inside permanent plastic casing. Drilling tools such as drill bits must not be inserted in plastic casing. This prohibition does not include the installation or repair of screens or development of the well or boring.
Plastic casing must not be used as an outside casing in wells and borings cased more than five feet into limestone or dolomite bedrock. In limestone and dolomite bedrock, plastic casing may be used as an inner casing if surrounded for the entire length by an outer steel casing.
A plastic cased well or boring completed in bedrock, whether screened or open hole, must be cased into the bedrock a minimum of five feet and the annular space surrounding the casing in bedrock must be filled with neat-cement grout or cement-sand grout according to part 4725.3050, subpart 7.
Plastic casing must not be driven. Use of a drive shoe with plastic casing is prohibited.
A person installing plastic casing must either seal a well or boring or remove and replace all casing when:
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
If a screen is attached or connected to the casing, the connection must be made by a threaded, solvent-welded, or welded joint, or by a nontoxic packer. Lead packers must not be used. A screen riser or leader must not extend more than 21 feet above the screen. A screen sump must not extend more than ten feet below the screen. The total combined length of screen riser or leader and screen sump must not exceed 21 feet. A screen riser, leader, or screen sump must comply with the confining layer requirements of part 4725.2020, subpart 1a. Multiple screens separated by a screen riser, leader, or sump are not permitted.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Gravel packs, filter sand, or stabilizer materials must be comprised of mineral material or inert, nontoxic artificial materials, contain less than five percent calcareous material, and must be graded, cleaned, and washed. Gravel packs, filter sand, or stabilizer materials must not extend:
more than ten feet above the top or below the bottom of the screen when a screen riser, leader, or screen sump is not installed;
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Water used for drilling, development, hydrofracturing, sealing, repair, or rehabilitation, other than water from the well or boring itself, must:
contain a free chlorine residual at all times, except for monitoring wells and remedial wells where chlorine will interfere with water quality analysis or remediation; and
Drilling additives, including bentonite, must meet the requirements of ANSI/NSF Standard 60-2016 as determined by a person accredited by ANSI. A drilling additive is a substance added to the air or water used in the fluid system of drilling a well or boring.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
The disposal of drilling mud, cuttings, treatment chemicals, and discharged water must be according to applicable state and local regulations. Drilling mud, cuttings, and discharged water must not be disposed in a manner that creates a health hazard. During test pumping, discharged water must be piped to a point of overland drainage.
MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773
September 2, 2008
[Repealed, 8 SR 1625]
September 2, 2008
The following grout materials as listed in part 4725.0100 are approved for filling an annular space between unconsolidated material or bedrock and a casing:
The following general requirements apply to the grouting of wells and borings.
Grouting must start immediately on completion of drilling and be completed before placing a well or boring in service.
The annular space to be grouted must be protected from collapse and the introduction of materials other than grout.
A steel plate, or a nontoxic metal, rubber, or plastic grout basket may be attached to the casing within ten feet of the bottom. Wood, burlap, or other organic material must not be used.
Grout must be pumped under pressure into the annular space from the bottom up to the established ground surface or base of the pitless adapter or unit. Grout must be pumped through the casing or through a tremie pipe placed within ten feet of the bottom of the space to be grouted. The tremie pipe may be retracted as grouting proceeds; however, the bottom of the tremie pipe must remain submerged in grout while grouting.
Grout flowing out of the annular space at the surface must meet the minimum specifications and densities in this chapter before grouting may stop.
Dumping of grout is not allowed except when the depth of the space to be grouted is less than ten feet.
Neat-cement grout or cement-sand grout must be allowed to set a minimum of 24 hours. Rapid setting cement must be allowed to set a minimum of 12 hours. Drilling, development, or pump operation is prohibited during the time the cement is setting.
When constructing a well or boring with a method such as mud or air rotary, auger, or jetting that creates an open annular space or drills a bore hole larger than the casing or casing couplings outside diameter, a grouting material specified in subpart 1 and the grouting methods specified in subpart 2 must be used to fill the annular space between the casing and the bore hole.
If the depth of the casing is 50 feet or less, the grout must extend from the bottom of the casing, top of the bentonite seal as specified in subpart 8, or top of the gravel pack, to the established ground surface, or the base of the pitless adapter or unit.
If the depth of the casing is more than 50 feet, the annular space below 50 feet must be filled with grout, except that the portion of the well or boring in an unconsolidated formation below 50 feet in depth may be filled with cuttings. The cuttings must be placed without bridging, and must be the unconsolidated materials taken from the bore hole. The annular space above 50 feet must be filled from:
a depth of at least 50 feet to the established ground surface or the base of a pitless adapter or unit; or
the top of the bentonite seal as specified in subpart 8 or the top of the gravel pack to the established ground surface or the base of a pitless adapter or unit.
The annular space between an inner and outer casing must be filled with neat-cement grout or cement-sand grout according to subpart 2.
When driving casing in an unconsolidated formation, a cone-shaped depression or temporary outer casing filled with bentonite grout, bentonite powder, or granular bentonite must be maintained around the outside of the casing. The bottom of driven casing, except for a drive-point, temporary casing, or outer casing that has a neat-cement or cement-sand grouted inner casing must be equipped with a drive shoe in accordance with part 4725.2250, subpart 15. Casing may only be driven through:
sandstone bedrock including the St. Peter, Jordan, Franconia, Ironton-Galesville, Mt. Simon, Hinckley, or Fond du Lac formations;
ten feet or less of limestone or dolomite bedrock including the Cedar Valley through Galena groups, the Platteville formation, or the Prairie du Chien group;
If a bore hole extends more than ten feet below the bottom of a screen, the bore hole must be filled with grout from the bottom of the bore hole to within ten feet or less of the screen.
The additional requirements in items A to C apply to grouting a well or boring in bedrock.
When bedrock is encountered in the construction of a well or boring, the casing must be equipped with a drive shoe driven firmly into stable bedrock or the casing must be grouted with neat-cement grout, or cement-sand grout from the bottom of the casing to the top of the bedrock.
When the casing of a well or boring extends more than ten feet into bedrock, or extends through any portion of a bedrock confining layer, the casing must be installed in a bore hole 3.0 inches larger, or 3.5 inches larger for casings deeper than 100 feet and larger than 12 inches inside diameter, than the outside diameter of the casing or couplings, whichever is larger, and the annular space in bedrock must be grouted with neat-cement grout or cement-sand grout, except that steel casing may be driven more than ten feet in a sandstone formation.
If a cavern more than twice the diameter of the bore hole exists or the grout level fails to rise after insertion of either more than one cubic yard of grout or the quantity of grout necessary to fill ten vertical feet of hole, then the following grouting materials and methods may also be used in the portions where the conditions exist:
pouring of a mixture of gravel or stone aggregate not larger than one-half inch in diameter while simultaneously pumping neat-cement grout or cement-sand grout through a tremie pipe in a ratio not to exceed five parts aggregate to one part grout;
pumping a mixture of gravel or stone aggregate not larger than one-half inch in diameter and cement-sand grout or neat-cement grout in a ratio not to exceed five parts gravel or aggregate to one part Portland cement; or
pumping of alternate, equal thickness layers of cement-sand grout or neat-cement grout and pouring gravel or stone aggregate not larger than one-half inch in diameter. Individual layers of aggregate must not exceed ten feet in thickness. Aggregate must not be emplaced in a confining layer.
Neat-cement grout or cement-sand grout must be pumped through the casing or through a tremie pipe. The aggregate must be poured into the bore hole at a rate that prevents bridging.
A layer of bentonite pellets, bentonite chips, or granular bentonite not to exceed five feet in thickness is allowed between a gravel pack and grout. The bentonite pellets, bentonite chips, or granular bentonite must not extend into a confining layer or extend more than ten feet above the static water level, and must be poured without voids or bridging. A tremie pipe must be inserted to within ten feet of the top of the pellets, chips, or granular bentonite, and the annular space grouted to the established ground surface or base of the pitless unit or adapter.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A connection or fitting 12 inches or more above the established ground surface into the top or side of a casing must be constructed to be weatherproof and insect proof. The connection, including a cap, cover, electrical connection, water treatment connection, discharge piping, vent, access pipe, or other connection to the casing must consist of:
a sanitary well seal with a one-piece top plate, compression gasket, and noncorrodible draw bolts. The cap or seal must be equivalent to the casing in weight and strength. If the well or boring is in a building that meets the requirements in part 4725.2175, a two-piece top plate, compression gasket, and noncorrodible draw bolts may be used.
A connection to, or a fitting on a casing made less than 12 inches above the established ground surface must be constructed to be watertight, vermin-proof, and provide complete clearance within the internal diameter of the casing. The connection must not be submerged in water at the time of installation. The connection must be made at or above the frost line. The connection or fitting must consist of a:
threaded connection equivalent to the material and threading standards of ASTM A53/A53M-04a, ASTM A589-96 (2001), API Standard 5L-04, ASTM A312/A312M-04b, or ASTM F480-02;
welded connection for steel or stainless steel casing where:
the welded fitting must:
fully integrate branch reinforcement and maintain full casing strength by providing casing reinforcement, with reinforcement tapering at the sides of the fitting;
the installer of a welded fitting must:
use a guide or template for cutting the hole in the casing, or use a properly sized drilled hole;
field-weld the fitting by holding the welding rod in a vertical or horizontal position, or bench-weld the fitting before field installation, with a welding rod as corrosion-resistant as the casing;
solvent welded connection for plastic casing equivalent to the standards of ASTM F480-02, or part 4725.2550;
bolted sleeve-type coupling meeting ANSI/AWWA Standard C219-01 where:
pitless adapter or pitless unit meeting the requirements of part 4725.4850, subpart 1. A welded, solvent welded, or threaded coupling, adapter, or swaged fitting meeting the material standards of part 4725.2350, 4725.2550, or 4725.6650 may be used to connect a casing to a pitless adapter or unit.
Electrical wire must enter a casing, cap, cover, or pump base a minimum of 12 inches above the established ground surface except for a well or boring completed at-grade in accordance with part 4725.6850. Electrical wires above the ground surface must be contained within a conduit or the casing. The electrical wire connection through the casing, cap, cover, or pump base must be made watertight and vermin-proof with a compression fitting, gasket, or electrical conduit installed according to Minnesota Statutes, section 326B.35, or caulk meeting the standards of ANSI/NSF Standard 14-2003 or 61-2003e.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; L 2007 c 140 art 5 s 32; art 13 s 4; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A pump or pump base installed on a well must be constructed so no unprotected openings exist into the interior of the pump or well casing.
A hand pump, hand pump head, stand, or similar device must have a closed and screened spout, directed downward. The pump must have a concrete slab at least four inches thick extending horizontally at least one foot in every direction from the well casing and sloped to divert water away from the casing. A watertight seal must be provided between the casing and the slab.
A reciprocating pump rod must operate through a stuffing box, packing gland, or other watertight and vermin-proof fitting.
A water lubricated vertical turbine pump must be lubricated with water from the well or a potable source.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
No connection between a well or boring and another well, boring, water supply system, or contamination source is allowed unless the connection is:
protected with a backflow prevention device as specified in UPC sections 603.0 to 603.5.23.4 as incorporated by part 4714.0050;
protected with a backflow prevention device as specified in parts 1505.2100 to 1505.2800 if the well is an irrigation well used for chemigation; or
between wells or borings that meet the construction standards of this chapter, are used for the same purpose, and have equivalent water quality.
This part does not apply to a water distribution system after the pressure tank; however, this part does not exempt water distribution systems otherwise regulated by chapter 4714.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
A well or boring from which groundwater flows above the established ground surface without pumping must be constructed to prevent erosion of the aquifer and the confining layer. Casing must be installed into the flowing aquifer to prevent water flowing up the outside of the casing. The requirements in this part are in addition to other requirements of this chapter.
A flowing well or boring that flows 70 gallons per minute or less, and that has an artesian pressure ten pounds per square inch or less, must be constructed by:
drilling a bore hole larger than the casing into the flowing aquifer, installing casing into the flowing aquifer, and grouting the annular space surrounding the casing with neat-cement grout or cement-sand grout from the bottom of the casing to the base of the pitless adapter or unit, or to the established ground surface according to part 4725.3050;
for a bored geothermal heat exchanger, grouting the annular space surrounding the bored geothermal heat exchanger piping with neat-cement grout or cement-sand grout from the bottom of the bore hole to the established ground surface or upper termination of the bored geothermal heat exchanger piping.
A well or boring, including a bored geothermal heat exchanger boring, must be constructed according to the requirements in this subpart when:
the artesian flow rate at the established ground surface is greater than 70 gallons per minute;
the commissioner designates an area where the use of standard construction techniques have resulted in uncontrolled flows, or where hydrogeologic conditions such as eroded or unstable confining layers require special construction to successfully complete a well or boring and confine the artesian pressure.
A well or boring meeting the criteria in item A must be constructed by:
installing an outer steel casing into, but not through, the confining layer overlying the flowing aquifer, except that the outer casing may terminate in a competent bedrock above the confining layer. The outer steel casing is not required to meet the material specifications for casing in part 4725.2350 if the casing is of sufficient strength to withstand the structural load imposed by conditions both inside and outside the well or boring. The casing must be installed by drilling a bore hole a minimum of 3.0 inches larger, or 3.5 inches larger for casings deeper than 100 feet and larger than 12 inches inside diameter, than the outside diameter of the casing or couplings, whichever is larger, into the confining layer overlying the flowing aquifer. The bore hole must not penetrate the entire thickness of the confining layer. Steel casing must be installed into the confining layer and neat-cement grout or cement-sand grout must be pumped into the annular space surrounding the casing from the bottom of the casing to the established ground surface or base of the pitless adapter or unit;
drilling a bore hole a minimum of 3.0 inches larger, or 3.5 inches larger for casings deeper than 100 feet and larger than 12 inches inside diameter, than the outside diameter of the inner casing or couplings through the confining layer into the flowing aquifer;
A flowing well or boring must be provided with flow control capable of stopping all flow, consisting of a valved pipe connection, watertight pump connection, specially designed pitless unit, or a receiving tank set at an altitude corresponding to that of the artesian head.
A water discharge from a flowing well or boring that disposes of water to the surface, a surface water body, sewer, or subsurface must:
Temporary wells and borings that flow, and are sealed within 30 days of the time construction begins, are not required to be constructed according to this part, but must be constructed to prevent erosion of the aquifer, drill hole, or surrounding property, and must be sealed to stop all flow with neat-cement grout or cement-sand grout according to part 4725.3850.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
A person who has constructed a well must attach a well identification label provided by the commissioner to the well before placing the well into service unless the well is sealed within 90 days of construction.
The well identification label must be attached to the well casing in a visible location using a stainless steel clamp, band, or strap. Alternatively, the label may be attached to a concrete pump base or pedestal, or at-grade well vault using screws or fasteners.
The property owner must maintain the well identification label in a readable condition.
The well identification label must not be removed except to work on the well. On completing work, the label must be reattached.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
When the commissioner designates an area where contamination is detected as a special well and boring construction area, a well or boring must not be constructed, repaired, or sealed until the commissioner has reviewed and approved a proposed plan submitted by the installer. Sealing, repair, construction, and location must comply with the approved plans. In addition to the information on the permit or notification, the plan must include the:
The commissioner may require water quality monitoring by the property owner, well or boring owner, or other person in a designated special construction area if the commissioner finds monitoring is needed to determine the degree of contamination.
The commissioner may specify well and boring location and construction requirements more stringent than those specified in this chapter if the commissioner determines, based on an assessment of hydrogeologic conditions and contaminant characteristics, that additional requirements are needed to protect the public health or prevent degradation of the groundwater.
The commissioner shall require the owner of a newly constructed contaminated well in a special well and boring construction area to install, use, and monitor an effective water treatment device if the commissioner determines that the device is reasonably necessary to ensure a safe drinking water supply or monitor the degree of contamination.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Chemicals placed in a well or boring to increase the yield, remove or treat contaminants or objectionable tastes or odors, or rehabilitate the well or boring must meet the requirements of ANSI/NSF Standard 60-2016 as determined by a person accredited by ANSI. Sodium or calcium hypochlorite may be used if registered by the United States Environmental Protection Agency according to the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), section 3(c)(7)(A), as an antimicrobial pesticide for use in potable water. Treatment chemicals must be neutralized or removed from the well, boring, and any connected piping systems prior to use of the well or boring. This part does not apply to chlorine or other treatment chemicals added to a water distribution system, or to a drilling additive used according to part 4725.2950.
Before treating a well or boring with an acid, all confined spaces enclosing the well or boring must be blown out with fresh air before entry and a supply of fresh air must be provided during occupancy. When there is a question of adequate fresh air supply, a self-contained breathing apparatus must be worn.
The well or boring must not be placed back into service until the pH is within one pH unit of the pretreatment value.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211; 45 SR 986
April 30, 2021
The property owner must:
have a defective part of a well or boring repaired, including a broken, punctured, or otherwise defective or unserviceable casing, screen, fixture, seal, connection, cover, or cap;
eliminate injection or disposal of wastes, surface drainage, or flood water, directly entering a well or boring; and
disconnect a cross-connection between a well or boring and a public water system unless approved by the public water supplier and protected with an air gap or backflow prevention device according to UPC sections 603.0 to 603.5.23.4 as incorporated by part 4714.0050.
A well or boring not repaired or corrected must be permanently sealed.
Materials used in maintenance, replacement, or repair must meet the requirements of this chapter for new installation.
When all casing is removed from a well or boring, the installation of new casing or the reinstallation of casing is considered new construction and must meet all the requirements of this chapter for new construction, including termination of the casing at least 12 inches above the established ground surface, and compliance with the applicable isolation distance requirements.
A noncomplying well or boring constructed prior to July 15, 1974, may be repaired as long as the repair meets the requirements of this chapter.
A well or environmental bore hole with the upper termination of the casing buried below the established ground surface must have the casing extended 12 inches above the ground surface when the well or boring is uncovered.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
A well or boring, including an unsuccessful well or boring, regardless of when constructed, that is not in use, and that has not been issued a maintenance permit, or that is required to be sealed according to Minnesota Statutes, section 103I.301, must be sealed according to this part by a contractor licensed or registered according to this chapter.
Materials, debris, and obstructions that may interfere with sealing must be removed from the well or boring. Sand, aggregate, or fill materials must be removed when sealing a well or boring, except that:
sand from a blasted and bailed sandstone formation may remain in a blasted and bailed sandstone formation; and
The open annular space surrounding a casing must be grouted by:
removing the casing and filling the well or boring with grout. If casing is to be removed from a collapsing formation, grout must be inserted so that the bottom of the casing remains submerged in grout; or
perforating or ripping the casing and forcing grout through the perforations. Grouting must start within 24 hours of perforating. Perforations or rips must penetrate the full thickness of the casings to be perforated or ripped. Casing to be perforated or ripped must:
be perforated with a minimum of one-half square inch of open area in each foot of casing for casings 16 inches in diameter and smaller, and one square inch of open area in each foot of casing for casings larger than 16 inches in diameter. No perforation shall have an open area of less than one-eighth square inch;
be perforated with a single hole at least two square inches in open area in each five feet of casing; or
be ripped a minimum of five feet for every 20 feet of casing.
Casing must be perforated or ripped through the entire length of a confining layer.
Casing is not required to be removed, perforated, or ripped if a single casing extends less than 20 feet into the first bedrock encountered, and the bedrock is sandstone or limestone, or the casing was driven through an unconsolidated formation, sandstone, or shale.
A well or boring must be sealed by filling the well or boring, including an open annular space, with grout or approved sealing materials to within two feet of the established ground surface or floor. Grout must be pumped through a tremie pipe or the casing from the original bottom of the well or boring upward. The bottom of the tremie pipe must be inserted to within ten feet of the bottom of the well or boring, and remain submerged in grout while grouting.
The portion of a well or boring in unconsolidated material must be filled with bentonite grout, neat-cement grout, or cement-sand grout. The grout must be pumped through a tremie pipe or the casing from the bottom of the well or boring upward to within two feet of the established ground surface. Clean sand or cuttings equal to the volume of bentonite grout may be mixed with the bentonite grout, or poured into the well or boring while bentonite grout is pumped through a tremie pipe. The sand or cuttings must be poured at a rate which prevents bridging.
In addition to the grout materials approved in subpart 4, a well or boring 16 inches or greater in inside diameter, less than 200 feet in depth, completed in unconsolidated materials, and containing less than 20 feet of water may be sealed by pouring at a rate sufficient to completely fill the well or boring without bridging:
uniformly mixed dry bentonite powder or granular bentonite and sand in a ratio of one part bentonite by volume to five parts sand;
clean unconsolidated materials including clay, sandy clay, and silty clay with a permeability of 10-6 centimeters per second or less;
granular, pelletized, or chipped bentonite not to exceed three-fourths inch in diameter along with sufficient water to hydrate the bentonite.
Sealing materials must have bearing strength sufficient to prevent subsidence and support traffic or building loads.
The portion of a well or boring in bedrock must be sealed with neat-cement grout or cement-sand grout.
The materials and methods described in item B are approved for sealing in those uncased bedrock portions of a well or boring where the following conditions exist:
the grout level fails to rise after insertion of more than one cubic yard of grout or the quantity of grout necessary to fill ten vertical feet of hole.
The materials and methods in this item are approved in those portions of a well or boring where the conditions in item A exist:
pouring a mixture of gravel or stone aggregate not larger than one-half inch in diameter while simultaneously pumping neat-cement grout or cement-sand grout in a ratio not to exceed five parts aggregate to one part grout;
pumping a mixture of gravel or stone aggregate not larger than one-half inch in diameter and neat-cement grout or cement-sand grout in a ratio not to exceed five parts gravel to one part Portland cement; or
placing alternate, equal thickness layers of cement-sand grout or neat-cement grout and gravel or stone aggregate not larger than one-half inch in diameter. Neat-cement grout or cement-sand grout must be pumped through the casing or a tremie pipe. The aggregate must be poured into the bore hole at a rate that prevents bridging. Individual layers of aggregate must not exceed ten feet in thickness except in blasted and bailed sandstone formations, where sand may be used to fill the entire portion of the blasted and bailed sandstone. Aggregate must not be emplaced in a confining layer or inside of casing.
In addition to the grout materials approved in subpart 5, a well or boring 16 inches or greater in inside diameter, less than 200 feet in depth, completed in bedrock, and containing less than 20 feet of water, may be sealed by pouring concrete at a rate sufficient to completely fill the well or boring without bridging.
The discharge from a flowing well or boring must be stopped and the well or boring sealed according to this part with neat-cement grout or cement-sand grout. It is approved to use rapid-setting cement, or to use hematite or barite as a weighting agent in a proportion not to exceed equal parts weighting agent and Portland cement. When a well or boring cannot be sealed as described in this part, the licensee or registrant must notify the commissioner.
The casing and grout seal must not be disturbed after a well or boring is sealed, except that the casing may be cut off at the base of an excavation encountering a sealed well or boring.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
A property owner is responsible for having a contractor licensed or registered in accordance with part 4725.0475 seal an unused well or boring except in accordance with subparts 2 and 5.
When a person, including a licensee or registrant seals a well or boring in violation of these rules, the person is responsible for sealing the well or boring in accordance with this chapter.
A licensee or registrant must report to the commissioner a well or boring that the licensee or registrant knows is not in use and is not sealed.
An unsuccessful or "test" well or boring must be sealed in accordance with part 4725.3850 by the licensee or registrant who constructed the well or boring, unless the property owner has the well or boring sealed by another licensed or registered contractor, or completes the well or boring and places it in use.
A person who buries, or constructs a building over, an unsealed, unused well or boring is responsible for having the well or boring sealed by a licensed or registered contractor.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Parts 4725.4050 to 4725.6050 are standards that apply to water-supply wells in addition to the requirements in parts 4725.2010 to 4725.3875.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Bentonite drilling fluids used to construct or repair a water-supply well must have a measurable chlorine residual at all times during drilling or repair, except for a remedial well where chlorine will interfere with water quality analysis or remediation.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
This part applies to water-supply wells, including private drinking water supply, public drinking water supply, irrigation, commercial, groundwater thermal exchange, and remedial wells completed in or below limestone or dolomite. This part does not apply to borings, monitoring wells, or dewatering wells.
Plastic casing must not be used as an outside casing in a water-supply well cased more than five feet into limestone or dolomite bedrock, except that an inner plastic casing may be installed entirely inside an outer steel casing in accordance with part 4725.2250, subpart 8.
A casing that extends more than ten feet into limestone or dolomite bedrock must be installed in a bore hole a minimum of 3.0 inches larger, or 3.5 inches larger for casings deeper than 100 feet and larger than 12 inches inside diameter, than the outer diameter of the casing or couplings, whichever is larger.
A water-supply well used to provide potable water must not be completed in limestone or dolomite bedrock unless the limestone or dolomite bedrock is overlain by at least 50 feet of unconsolidated material, sandstone, or shale that extends in all directions around the well for a minimum one-mile radius. Limestone or dolomite bedrock includes the Cedar Valley through Galena groups, Platteville formation, and the Prairie du Chien group.
The commissioner may establish limestone and dolomite bedrock well construction maps identifying areas of known or suspected contamination, areas with unique hydrologic or geologic conditions, or areas where protective conditions exist, including low permeability overlying materials, favorable groundwater gradients, or reduced contaminant loading in recharge areas. The conditions in item A do not apply in areas designated as approved for drilling on the limestone and dolomite bedrock well construction maps published by the commissioner.
Where a potable water-supply well meeting the conditions of subpart 4 or a nonpotable water-supply well is completed in limestone or dolomite bedrock, the following apply:
If the static water level in the well is more than ten feet above the limestone or dolomite:
steel casing must be installed into the limestone or dolomite by driving the casing with a drive shoe through unconsolidated materials or sandstone into, but not more than ten feet into, the limestone or dolomite; or
a bore hole must be drilled into the limestone or dolomite and steel casing installed to the bottom of the bore hole. If the bore hole extends more than ten feet into the limestone or dolomite, the bore hole must be a minimum of 3.0 inches larger, or 3.5 inches larger for casings deeper than 100 feet and larger than 12 inches inside diameter, than the outside diameter of the casing or couplings, whichever is larger. The annular space surrounding the casing must be grouted from the bottom of the casing to the top of the bedrock with neat-cement grout or cement-sand grout. The unconsolidated materials portion of the annular space must be grouted according to part 4725.3050, subparts 1 to 3.
If the static water level in the well is less than ten feet above the limestone or dolomite, a bore hole must be drilled a minimum of 3.0 inches larger, or 3.5 inches larger for casings deeper than 100 feet and larger than 12 inches inside diameter, than the outside diameter of the casing or couplings, whichever is larger. The bore hole must extend a minimum of 20 feet below the static water level. Steel casing must be installed to the bottom of the bore hole. The annular space from the bottom of the casing to the top of bedrock must be filled with neat-cement grout or cement-sand grout. The unconsolidated materials portion of the annular space must be grouted according to part 4725.3050, subparts 1 to 3.
A water-supply well completed below limestone or dolomite where the conditions of subpart 4 apply must be constructed by drilling a bore hole a minimum of 3.0 inches larger, or 3.5 inches larger for casings deeper than 100 feet and larger than 12 inches inside diameter, than the outside diameter of the casing or couplings a minimum of ten feet below the limestone or dolomite, and a minimum of ten feet below the static water level. Steel casing must be installed to the bottom of the bore hole, and the annular space from the bottom of the casing to the top of bedrock must be filled with neat-cement grout or cement-sand grout. The unconsolidated materials portion of the annular space must be grouted according to part 4725.3050, subparts 1 to 3.
A remedial well is exempt from the requirement in subpart 5 to extend the casing 20 feet below the static water level if the well screen or open hole intersects the water table, the casing terminates no more than ten feet above the static water level, and all casing installed in limestone or dolomite is grouted with neat-cement grout or cement-sand grout.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
The minimum horizontal distance between a water-supply well and the ordinary high water level of a stream, river, pond, storm water retention pond, or lake is 35 feet. The isolation distance does not apply to:
an area protected by a flood control structure accepted by the United States Federal Emergency Management Agency (FEMA), as designated on a FEMA flood map;
a wetland, grassed waterway, depression, culvert, or ditch holding water less than six months of the year; or
A water-supply well must be constructed to prevent the entry of flood water into the well by:
installing a watertight seal and extending the casing ten feet above the established ground surface, if the regional flood level is more than five feet above the established ground surface;
installing an outer, neat-cement grouted protective casing in accordance with part 4725.6755, subpart 2, item B, extending the protective casing and well casing a minimum of two feet above the established ground surface, and installing a waterproof threaded cap or a waterproof compression seal with drawbolts and a one-piece top plate on both casings; or
extending the casing a minimum of two feet above the established ground surface, installing a sealed spool, or flowing well pitless unit, and installing a waterproof, nonvented compression seal.
The requirements in this subpart do not apply to a water-supply well located in an area protected by a flood control structure accepted by the United States Federal Emergency Management Agency (FEMA), as designated on a FEMA flood map.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A water-supply well must be located where there is optimum surface drainage and at the highest practical elevation. Whenever possible, water-supply wells should not be located down slope or down gradient of a contamination source. A water-supply well must be constructed as far as practical from a contamination source, but no less than the distances in this part.
The isolation distances in this part are minimum distances measured horizontally from the closest part of the upper termination of the water-supply well casing to the closest part of the contamination source, or the vertical projection of the contamination source on the established ground surface, whichever is closer.
Where this chapter establishes a minimum regulatory volume of a liquid, the volume of multiple tanks, each below the minimum, are not additive, unless the tanks are interconnected without backflow protection.
The minimum isolation distances must be maintained between a new well and a source of contamination no longer in use, unless all contaminants have been removed from the source, and visibly contaminated soils have been removed.
A contamination source must not be placed, constructed, or installed any closer to a water-supply well than the distances in this part.
A water-supply well must be no less than:
300 feet from:
the absorption area of a soil dispersal system with an average design flow greater than 10,000 gallons per day;
a landfill or dump containing mixed municipal solid waste from multiple persons, except for a disposal area of household solid waste from a single residence regulated by item E, subitem (20);
a permitted demolition debris landfill, except for a disposal area for construction debris or demolition debris regulated by item E, subitem (19);
a liquid manure storage basin or lagoon that is unpermitted or noncertified according to chapter 7020;
except that the minimum distance to a sensitive water-supply well is increased for subitems (1) to (6) to 600 feet as provided in subpart 2;
150 feet from:
a tank or container holding:
25 gallons or more, or 100 pounds or more dry weight, of an agricultural chemical, or an area used to fill or clean agricultural chemical application equipment with these quantities, not protected with safeguards;
56 gallons or more, or 100 pounds or more dry weight, of a hazardous substance not protected with safeguards; or
1,100 gallons or more of petroleum not protected with safeguards as specified in chapter 7150 or 7151;
the absorption area of a soil dispersal system serving a facility such as a hospital, nursing home, mortuary, veterinary clinic, health care clinic, or similar facility handling infectious or pathological wastes, except as provided in item A, subitem (1), and except that the minimum distance to a sensitive water-supply well is increased to 300 feet as provided in subpart 2;
a municipal wastewater stabilization pond with less than 500 gallons/acre/day leakage, except that the minimum distance to a sensitive water-supply well is increased to 300 feet as provided in subpart 2;
an industrial wastewater stabilization pond, except that the minimum distance to a sensitive water-supply well is increased to 300 feet as provided in subpart 2;
a municipal or industrial wastewater spray irrigation area, except that the minimum distance to a sensitive water-supply well is increased to 300 feet as provided in subpart 2; and
a liquid manure storage basin or lagoon that does not have a concrete or composite liner, but has an earthen liner that was constructed under a Minnesota Pollution Control Agency permit or is certified according to chapter 7020, except that the minimum distance to a sensitive water-supply well is increased to 300 feet as provided in subpart 2;
100 feet from:
a solid manure storage area not covered by a roof, except that the minimum distance to a sensitive water-supply well is increased to 200 feet as provided in subpart 2;
a safeguarded area used to store agricultural chemicals, or clean or fill agricultural chemical application equipment that is protected with safeguards as defined in parts 1505.3010 to 1505.3150 for bulk pesticides, or with safeguards as specified in standards of the Department of Agriculture for fertilizers under parts 1510.0370 to 1510.0408 and Minnesota Statutes, chapter 18C;
an underground storage tank holding 56 or more gallons, or 100 pounds dry weight, of a hazardous substance, or with more than 1,100 gallons of petroleum, if protected with safeguards as defined in chapter 7150;
an aboveground storage tank with 56 or more gallons, or 100 pounds dry weight, of a hazardous substance, or with more than 1,100 gallons of petroleum, if protected with safeguards as defined in chapter 7151;
a liquid manure storage basin or lagoon with a concrete or composite liner in accordance with chapter 7020, except that the minimum distance to a sensitive water-supply well is increased to 200 feet as provided in subpart 2;
an unroofed animal feedlot holding 300 or more animal units, except that the minimum distance to a sensitive water-supply well is increased to 200 feet as provided in subpart 2;
a pipeline used to transport petroleum or crude oil to a petroleum refinery or distribution center;
75 feet from a cesspool, seepage pit, leaching pit, or dry well, except that the minimum distance to a sensitive water-supply well is increased to 150 feet as provided in subpart 2;
50 feet from:
a safeguarded area used to store agricultural chemicals, or fill or clean agricultural chemical application equipment that is covered with a permanent watertight roof and protected with safeguards as defined in parts 1505.3010 to 1505.3150 for bulk pesticides, or with safeguards as specified in standards of the Department of Agriculture for fertilizers under parts 1510.0370 to 1510.0408 and Minnesota Statutes, chapter 18C;
an animal feedlot holding more than one animal unit, except as provided in item C, subitem (6), and except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
a feeding or watering area within a pasture holding more than one animal unit, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
an animal or poultry building, including a horse riding arena, holding more than one animal unit, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
the absorption area of a soil dispersal system except as provided in items A, subitem (1), and B, subitem (2), or a privy, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
a septic tank, sewage sump except as provided in item G, subitem (1), watertight sewage treatment device except as provided in item C, subitem (7), or watertight sewage holding tank;
a source of pollution or contamination that may drain into the soil except as provided in this part;
a floor drain, grate, or trough connected to a buried sewer, except as provided in item G, subitem (5);
a storage area for bulk road deicing chemicals, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
the buried piping of a bored geothermal heat exchanger or any other closed loop geothermal heat exchanger, except as provided in items F, subitem (1), and H, subitem (2);
a sewage, septage, or sludge, land-spreading area, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
a disposal area for construction debris or demolition debris, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
a disposal area for household solid waste from a single residence, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
a disposal area for water treatment backwash, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
an industrial cooling water pond, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
a gray-water dispersal area, except that the minimum distance to a sensitive water-supply well is increased to 100 feet as provided in subpart 2;
multiple tanks or containers of agricultural chemicals, hazardous materials, or hazardous wastes, for residential retail sale or use, each holding less than 56 gallons or 100 pounds dry weight, where the aggregate volume of the tanks and containers exceeds 56 gallons or 100 pounds dry weight;
a water treatment backwash holding basin, reclaim basin, or surge tank with a direct sewer connection;
35 feet from:
20 feet from:
a sewage sump with a capacity of less than 100 gallons that has been successfully tested according to UPC section 712.0 or 723.0 as incorporated by part 4714.0050 and constructed according to UPC sections 710.8, 710.10, and 710.12 as incorporated by part 4714.0050;
a pit or unfilled space below the established ground surface that is four feet or more in depth, except a basement or building crawl space;
a buried sewer serving one building, or two or less single-family residences, constructed of cast iron or plastic pipe according to the material specifications, methods, and testing protocol described in UPC table 701.1 and section 723.0 as incorporated by part 4714.0050 or a floor drain connected to the buried sewer, except for:
a sewer serving a facility such as a hospital, nursing home, mortuary, veterinary clinic, health care clinic, or similar facility handling infectious or pathological wastes;
an animal building, feedlot, confinement area, or kennel holding 0.1 to 1.0 animal unit, except that the minimum distance to a sensitive water-supply well is increased to 40 feet as provided in subpart 2;
a water treatment backwash holding basin, reclaim basin, or surge tank, and associated piping, with a backflow protected sewer connection; and
The distances in items A to F are exceptions to the isolation distances in subpart 1. The isolation distances in subpart 1 are doubled between a sensitive water-supply well and a contamination source directly entering the soil. A sensitive water-supply well must be located at least:
600 feet from the absorption area of a soil dispersal system with an average design flow greater than 10,000 gallons per day, a landfill or dump containing mixed municipal solid waste from multiple persons, a permitted demolition debris landfill, a municipal or industrial wastewater rapid infiltration basin, a municipal wastewater stabilization pond with 500 or more gallons/acre/day leakage, or a liquid manure storage basin or lagoon that is unpermitted or noncertified according to chapter 7020;
300 feet from the absorption area of a soil dispersal system serving a facility such as a hospital, nursing home, mortuary, veterinary clinic, health care clinic, or similar facility handling infectious or pathological wastes; a municipal wastewater stabilization pond with less than 500 gallons/acre/day leakage; an industrial wastewater stabilization pond; a municipal or industrial wastewater spray irrigation area; or a liquid manure storage basin or lagoon that does not have a concrete or composite liner, but has an earthen liner that was constructed under a Minnesota Pollution Control Agency permit or is certified according to chapter 7020;
200 feet from a manure storage area, a liquid manure storage basin or lagoon with a concrete or composite liner according to chapter 7020, or an unroofed animal feedlot holding 300 or more animal units;
100 feet from an animal feedlot holding more than one animal unit except as provided in item C; an animal or poultry feeding or watering area within a pasture holding more than one animal unit; an animal or poultry building including a horse riding arena holding more than one animal unit; the absorption area of a soil dispersal system; a privy; a storage area for road deicing chemicals; a sewage, septage, sludge, or waste landspreading area; a disposal area for construction or demolition debris; a disposal area for household solid waste from a single residence; a disposal area for water treatment backwash; an industrial cooling water pond; a gray-water dispersal area; or similar contamination source; and
40 feet from an animal building, feedlot, confinement area, or kennel holding 0.1 to 1.0 animal unit.
An irrigation well used only for nonpotable purposes must be at least 20 feet from a fertilizer chemigation supply tank conforming to the applicable requirements, setbacks, safeguarding, antipollution devices, purging, and posting requirements of parts 1505.2100 to 1505.2800.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
A potable water-supply well must be cased to a depth of at least 15 feet from the established ground surface. The top of a gravel pack must terminate at least 15 feet below the established ground surface.
MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
The following requirements apply to a new potable water-supply well.
A water-supply well must be developed to remove drilling fluid, native silts and clays deposited during drilling, and the predetermined finer fraction of the natural formation or the gravel pack.
A new water-supply well must not produce a sustained quantity of more than five milligrams per liter (mg/l) of sand, or more than 200 mg/l of silt and clay as defined in part 4725.1851, subpart 4, item A, for potable water at the design capacity of the well, except when geological conditions preclude meeting the standard, and the well owner, licensee, and commissioner agree to accept the sediment in a stipulated agreement.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Materials used in construction of a potable water-supply well that contact water must not exceed eight percent lead except that solders and flux must not contain more than 0.2 percent lead.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A water-supply well used to provide water for nonpotable purposes such as irrigation, heating and cooling, or industrial processing, that is not used for purposes listed in part 4725.0100, subpart 35a, must be constructed according to parts 4725.2010 to 4725.5550, except parts 4725.4550, 4725.4650, and 4725.4750.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211; 45 SR 986
April 30, 2021
Except as provided in subpart 2, a connection to a casing of a water-supply well made less than 12 inches above the established ground surface must be made with a pitless adapter or pitless unit. The connection must not be submerged in water at the time of installation. Native materials must be packed tightly around the pitless adapter or pitless unit to the ground surface. The pitless adapter or pitless unit must:
be designed to be field-welded by holding the welding rod in a vertical or horizontal position, or bench-welded before field installation with a material as corrosion-resistant as the parent material;
connect to the casing by a threaded connection, welded connection, bolted flange with gasket, clamp and gasket, or compression gasket.
A welded, solvent welded, or threaded coupling, adapter, or swaged fitting meeting the material standards of part 4725.2350, 4725.2550, or 4725.6650 may be used to connect a casing to a pitless adapter or unit.
Additionally, a pitless unit using a compression seal must provide for the well casing to extend at least 2.5 inches into the throat of the pitless unit. The compression collar must be held in place with corrosion-resistant bolts, nuts, and washers. The installer of a clamp-on or weld-on pitless adapter must use a guide or template for cutting the hole in the casing to accommodate the pitless adapter.
A welded or threaded fitting meeting the requirements of part 4725.3150, subpart 2, may be connected to the side, cap, or cover of a water-supply well casing and be used for venting, remediation, measurement of water levels or testing, treatment, or for an electrical connection. A water discharge line must be connected with a pitless unit or pitless adapter.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 33 SR 211]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A pump that requires priming for ordinary use must not be installed on a water-supply well unless the well is only used for a water irrigation system. An irrigation well pump must be primed only with water free of contamination and carrying a measurable chlorine residual. An irrigation well equipped with a centrifugal pump may be primed without chlorination when the pump is filled with water taken directly from the well.
MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
As specified in UPC section 604.1 as incorporated by part 4714.0050, a suction line for a water-supply well must be constructed of:
A suction line extending outside the well casing must be protected by being:
installed within an outer, concentric pipe with the annular space between the pipes filled with water from the system and maintained at system pressure.
An unprotected suction line may be installed below the established ground surface for an irrigation well if the well is:
MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
A buried discharge line between a water-supply well casing and the pressure tank in an installation, including a deep well turbine or a submersible pump, must not be under negative pressure at any time. If a check valve is installed in a buried water line between the well casing and the pressure tank, the water line between the well casing and the check valve must meet the requirements of part 4725.5150 unless equipped with a vacuum release or combination air release and vacuum release device located between the check valve and the well. Pump discharge lines must be constructed of materials approved in part 4725.5150, subpart 1.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A pressure relief or air release valve on a pressure tank that contains subterranean gas and is located in a building must be vented to the outside.
A buried or partially buried pressure tank installed on a water-supply well must:
be identified with the manufacturer's name, a serial number, the allowable working pressure, and the year fabricated;
have an interior coating that complies with ANSI/NSF Standard 61-2003e if the tank has an interior coating in contact with water;
have a minimum one-fourth inch wall thickness for a steel pitless adapter tank attached directly to the well casing;
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A well vent must:
be constructed of materials complying with parts 4725.2250 to 4725.2650, or 4725.5150, subpart 1;
have watertight joints and terminate at least five feet above the regional flood level unless provided with a watertight seal as specified in part 4725.4350, subpart 2;
terminate a minimum of 12 inches above the established ground surface or the floor of a building as specified in part 4725.2175, except that a vent for a community public water-supply well must terminate a minimum of 18 inches above the established ground surface and the floor of a building as specified in part 4725.2175;
be screened with a noncorrosive mesh screen having openings of 1/16 inch or less and pointed downward; and
A screened vent incorporated into the underside of a well cap or cover may be used.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
This part applies to hydrofracturing a water-supply well, as defined in part 4725.0100, subpart 30f. A remedial water-supply well, or other well or boring regulated by this chapter, must not be hydrofractured. Hydrofracturing must be done by a well contractor licensed according to Minnesota Statutes, section 103I.525.
Water used for hydrofracturing must be potable water containing a chlorine residual. The use of surface water, unless obtained from a public water system, is prohibited.
Additives must meet the requirements of ANSI/NSF Standard 60-2016 as determined by a person accredited by ANSI.
Proppants may be used to hold the joints and fractures open, and must be inert, clean, and nontoxic materials, including chlorinated, noncalcareous, washed sand.
The following restrictions apply when hydrofracturing.
Hydrofracturing must not occur inside a casing. The upper packer must be a minimum of ten feet below the lower termination of a casing.
The following requirements apply when hydrofracturing. The person hydrofracturing must:
disinfect a hydrofractured water-supply well upon completion of hydrofracturing, according to part 4725.5550;
collect a water sample from a hydrofractured water-supply well used for drinking or other potable purposes, and test the sample according to part 4725.5650; and
complete and submit a well and boring construction record, or amended record, within 30 days of completion of hydrofracturing.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
A water-supply well must be disinfected according to this part. A disinfection procedure is presumed adequate when one or more water samples collected as specified in part 4725.5650 indicate the absence of total coliform bacteria.
A person installing a new well or pump must ensure that the well is pumped until three volumes of the water contained in the well are pumped or until the water is as clear as groundwater conditions allow. After pumping, the person installing a new well or new pumping equipment must disinfect the well and pumping equipment with chlorine at a concentration sufficient to produce at least 50 parts per million of free chlorine in all parts of the well. The chlorine solution must contact the well surfaces above the static water level. The chlorine solution must remain in the well at least two hours before pumping all the chlorinated water from the well and the solution from the distribution system.
A person repairing or modifying a well or pump must disinfect the well as specified in subpart 2 or disinfect at the start of the repair or reconditioning by applying chlorine at a concentration sufficient to produce 200 parts per million free chlorine in all parts of the well for the period of the well repair or reconditioning operation. Before taking water samples or returning the well to use, all chlorinated water must be pumped from the well and distribution system.
Chlorine materials must meet the requirements of ANSI/NSF Standard 60-2016 as determined by a person accredited by ANSI or be registered by the United States Environmental Protection Agency according to the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), section 3(c)(7)(A), as an antimicrobial pesticide for use in potable water. Chlorine compounds with additives such as perfumes or algaecides must not be used for disinfection. An alternate disinfection material may be used if the material is a biocide meeting the material and use standards of this part and provides biocidal activity equivalent to the chlorine concentrations and contact times required in this part.
Chlorine compounds in solid form used to comply with subparts 2 and 3 must be dissolved in potable water prior to placement in a water-supply well or circulated in the well to contact all well surfaces above the static water level, except that:
additional solid chlorine in excess of that necessary to produce the free chlorine required in subpart 2 or 3 may be added; and
solid chlorine may be used to disinfect a flowing well by placing the solid in the bottom of the well.
The requirement to disinfect a water-supply well does not apply to a remedial well if the disinfection will interfere with water quality analysis or create dangerous reactions with contaminants.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
Within 30 days of completion and before the use of a newly constructed potable water-supply well, the person constructing the well must assure that a water sample is collected from the well. A water sample is not required from a new pump installation in an existing well, or a well repair, unless a notification must be submitted according to part 4725.1820, item A.
The person constructing the well must inform the well owner that until analysis of one or more water samples from the well indicates the absence of total coliform bacteria, and the nitrate-nitrogen and arsenic analysis have been completed and reported, the well must not be used for human consumption.
The person constructing the well must assure that water samples are properly collected and submitted to a laboratory certified under parts 4740.2010 to 4740.2120. The laboratory must be certified to analyze total coliform bacteria nitrate-nitrogen, and arsenic, under the safe drinking water program test category. The laboratory reporting limit must be no greater than 1.0 milligrams per liter for nitrate-nitrogen, and no greater than 2.0 micrograms per liter for arsenic.
The sample must be analyzed for total coliform bacteria, arsenic, and nitrate-nitrogen. The person constructing the well must assure that the property owner and the commissioner receive a legible, reproducible copy of the analysis results within 30 days of analysis. The copy of analysis results sent to the commissioner must include the unique well number, the property owner's name and address, and the dates of sample collection and analysis.
If a water sample collected according to this part, or a water sample collected by the commissioner from a newly constructed potable water-supply well indicates the presence of total coliform bacteria, the person constructing the well is responsible for actions needed to eliminate possible causes of total coliform bacteria, redisinfect the well, and resample for total coliform bacteria.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 144.97; 144.98; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 31 SR 446; 33 SR 211
September 2, 2008
[Repealed, 33 SR 211]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A dug well must be constructed to comply with all requirements of this chapter including the materials, grouting, and casing standards. Where geological conditions preclude the possibility of completing a water-supply well with conventional drilling methods, materials, or casing, a variance may be granted under part 4725.0410 to install a dug well for a residential water supply using unconventional techniques or materials. A dug water-supply well may only be constructed in an unconsolidated formation.
A dug water-supply well must be protected with a cap or cover meeting the requirements of part 4725.3150, subpart 1, or a precast, overlapping, steel-reinforced, concrete cover at least four inches in thickness, or a locked, overlapping, metal cover at least 3/16 inch in thickness. The junction of cover with the well casing must be made with a watertight gasket and must be provided with a well vent according to part 4725.5450.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
In addition to the requirements of parts 4725.2010 to 4725.5650, a water-supply well used to provide water for a noncommunity or community water system must comply with the requirements in subparts 2 to 6.
The licensee must notify the commissioner of the proposed construction starting time of a community or noncommunity public water-supply well 24 hours in advance of beginning construction. The information may be placed on the notification form required in part 4725.1820 or may be reported by telephone, facsimile, or in person. The notification must be made between 8:00 a.m. and 4:30 p.m., Monday through Friday, excluding holidays.
A public water-supply well constructed in an unconsolidated formation using a rotary or other method that creates an annular space and uses a bentonite drilling fluid, in addition to the disinfection requirements of part 4725.5550, must be either:
disinfected upon completion of drilling and prior to grouting by placing a minimum 200 mg/l free chlorine solution in the bottom of the well and circulating the solution both inside the casing and in the annular space to the established ground surface for a minimum of 30 minutes; or
A public water-supply well constructed with a method that creates an open annular space must be grouted as specified in part 4725.3050 from within ten feet of the lower termination of the casing to the established ground surface or base of the pitless adapter or unit. Casing may be driven according to part 4725.3050, subpart 5.
A sampling faucet must be installed for each new public water-supply well. The faucet must be:
A well, previously not used as a public water-supply well, may be used as a noncommunity or community public water-supply well only if the well meets the standards of this chapter. Plans and specifications must be submitted to, and approved by, the commissioner prior to use as a public water-supply well. This provision is not meant to be used for the construction of a "test" well or environmental bore hole converted to a public water-supply well in order to circumvent the notification, inspection, and plan approval requirements of this chapter.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621
33 SR 211; 45 SR 986
April 30, 2021
In addition to the requirements of parts 4725.2010 to 4725.5825, a public water-supply well used to provide water for a community water system must comply with the requirements in subparts 1a to 8.
A licensee must not construct or materially alter a well, including adding or removing casing below the frost line for a well providing water to a community water system, until plans and specifications have been approved according to part 4720.0010.
A licensee must not construct a well for a community public water system until the site has been approved by the commissioner.
A well for a community public water system must be located according to the distances specified in parts 4725.2150, 4725.2185, 4725.4350, and 4725.4450, but in no case less than 50 feet from a source of contamination except:
the minimum isolation distance is 20 feet for contamination sources listed in part 4725.4450, subpart 1, item G, subitems (2), (3), (8), (9), (11), and (12);
the minimum isolation distance is 20 feet to an aboveground petroleum storage tank holding less than 1,100 gallons used for emergency pumping of a community public supply well if the petroleum storage tank:
the minimum isolation distance is ten feet for contamination sources listed in part 4725.4450, subpart 1, item H, subitem (1); and
there is no minimum distance to a pipe or conduit carrying only clear water from a floor drain in a community well house to a gravel pocket or French drain.
The established ground surface at the well site must be at least two feet above the highest known water elevation of a lake, pond, river, stream, or other body of surface water, the waters of which at the highest level would approach to within 50 feet measured horizontally of the well.
The established ground surface must be sloped to drain away from the well and be graded to prevent the accumulation and retention of surface water within 50 feet of the well. Filling must be protected from erosion by riprap or other suitable means.
The casing or casing extension must extend vertically at least 12 inches above the established ground surface, floor, or slab according to part 4725.2250, subpart 11.
Casing vents must be constructed in accordance with parts 4725.4850 and 4725.5450 and terminate a minimum of 18 inches above the established ground surface or floor of a building as specified in part 4725.2175.
The owner of a community public water-supply well must own or legally control, through a permanent easement, the property within a 50-foot radius of the well.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
In addition to the general standards in parts 4725.2010 to 4725.3875, and the standards for water-supply wells, in parts 4725.4050 to 4725.5550, a remedial well must:
have spark arresters installed if petroleum products or other flammable or explosive materials are present;
be equipped with a casing vent or collect and treat gases, if toxic or flammable gases are present; and
A remedial well is exempt from:
the distance from contamination source requirements in parts 4725.4350, subpart 1, and 4725.4450;
the requirement in part 4725.2250, subpart 11, to extend the casing 12 inches above the established ground surface if the remedial well is constructed according to part 4725.6850 for at-grade construction;
the requirement in part 4725.4250, subpart 5, to extend the casing 20 feet below the static water level if the well screen or open hole intersects the water table, the casing terminates no more than ten feet above the static water level, and all casing installed in limestone or dolomite is grouted with neat-cement grout or cement-sand grout;
A remedial well that is constructed to remove contaminants from the water surface by placing a screen or open hole across the contact of an unconsolidated formation and bedrock is exempt from the requirements of part 4725.2020, subpart 1, if the screen or open hole:
A remedial well may be constructed with stainless steel casing meeting ASTM Standard A312/312M-04b, having at least ANSI Schedule 5 for welded joints, and ANSI Schedule 40 for threaded joints.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
This part applies to a dewatering well as defined in Minnesota Statutes, section 103I.005, subdivision 4a. A dewatering well must be constructed, repaired, maintained, and sealed in accordance with the general standards in parts 4725.2010 to 4725.3875, and the requirements of this part. A dewatering well must not be used for a purpose other than dewatering. A dewatering well is exempt from the provisions in parts 4725.4050 to 4725.6050.
A discharge from a dewatering system must not connect to a potable water system.
A dewatering well cased and completed at-grade must conform to part 4725.6850.
A licensee who installs a dewatering well that causes the loss of an adequate private potable water supply must provide the private well owner with a temporary supply of potable water during the operation of the dewatering well. The supply must be adequate for drinking, cooking, and other household uses. The commissioner may require the private well to be tested to determine if a health risk exists before the licensee discontinues an alternate water supply. The licensee must assure that the required testing is completed and reported to the commissioner.
A dewatering well in an unconsolidated formation installed for less than 18 months and less than 50 feet in depth may be constructed and sealed according to the conditions and exemptions in items A to E.
Casing is not required to meet the standards of parts 4725.2350 to 4725.2650, if the casing is water tight, free of oil or other contaminants, and withstands the forces exerted on it during installation and removal.
The upper termination of the casing must be covered with a tamper-resistant overlapping cover on the casing as specified in part 4725.2250, subpart 17. The casing is not required to terminate at least 12 inches above the established ground surface if the casing extends at least 12 inches above the working grade. The working grade is the temporary elevation of the ground surface during a construction project.
The annular space is not required to be grouted to a depth of 50 feet according to part 4725.3050, subpart 3, if the annular space is filled with cuttings taken from the bore hole.
At 18 months after construction or sooner, the well must be sealed according to this chapter. A dewatering well installed for 18 months or less, not encountering a confining layer, less than 50 feet in depth, completed in an unconsolidated formation, and that is not flowing, may be sealed according to part 4725.7450, subpart 4.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
This part applies to monitoring wells as defined in Minnesota Statutes, section 103I.005, subdivision 14.
In addition to the general construction, repair, maintenance, and sealing requirements in parts 4725.2010 to 4725.3875, a monitoring well must be constructed, repaired, maintained, and sealed according to this part. A monitoring well is exempt from the requirements in parts 4725.4050 to 4725.6050.
A monitoring well that is not in use must be sealed.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Casing for a monitoring well must be steel or plastic casing meeting the standards of parts 4725.2250 to 4725.2650, or stainless steel or flush threaded polyvinyl chloride meeting the standards of this subpart.
A monitoring well may be constructed with flush threaded polyvinyl chloride (PVC) casing if:
the screen intersects the surface of the water table at the time of installation and the well is constructed so the joint between the two deepest casing sections is above the surface of the water;
the flush threaded PVC casing used meets the standards of ASTM F480-02, and the standards in Schedule 40 as referenced in ASTM Standard D1785-04.
A monitoring well may be constructed with stainless steel casing meeting ASTM Standard A312/A312M-04b, having at least ANSI Schedule 5 for welded joints and ANSI Schedule 40 for threaded joints.
The annular space of a monitoring well must be grouted from ten feet or less above the screen or open bore hole to the established ground surface according to part 4725.3050, except that no cuttings from the bore hole must be added to the grout. Neat-cement or cement-sand grout may terminate at the base of the manhole or vault for an at-grade installation.
Drilling fluids used to construct a monitoring well must comply with part 4725.2950, except that a free chlorine residual is not required.
A monitoring well, that is constructed to monitor contaminants at the water surface, by placing a screen or open hole across the contact of an unconsolidated formation and bedrock according to part 4725.6050, subpart 3, is exempt from part 4725.2020, subpart 1.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.122; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 18 SR 1222; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
The inner casing of a monitoring well, and when installed, the protective outer casing as specified in subpart 2, item B, with bentonite grout in the annular space, must be covered with a cap or cover according to part 4725.2250, subpart 17. The protective outer casing may be covered with an overlapping cap or cover without a compression gasket.
Either the inner casing or the protective outer casing must be closed with a watertight, locked cap or a wrench-tightened, threaded metal cap.
The top of the well must be constructed to prevent entry of flood waters according to part 4725.4350, subpart 2.
A monitoring well cased with plastic must be protected with an outer steel protective casing as specified in subpart 2, item B.
A monitoring well must be protected by:
surrounding the casing with a concrete pyramid or cone that has horizontal dimensions of at least 24 inches by 24 inches at the established ground surface, that rises 12 inches above the established ground surface at the casing, and has a base with a mass of at least three cubic feet below the established ground surface;
installing a steel outer casing meeting the material standards of part 4725.2350 that is at least 3.0 inches in diameter greater than the inner casing, that extends at least two feet above and four feet below the established ground surface, and that has bentonite grout, neat-cement grout, or cement-sand grout in the annular space between the casings from the bottom of the outer casing to the established ground surface; or
placing three posts at least four inches square or four inches in diameter around the well at equal distances from each other and two feet from the casing. The posts must extend two feet above and four feet below the established ground surface or to a depth of two feet if each post is set in concrete to a depth of two feet. The posts must be made of reinforced concrete, decay-resistant wood, or ASTM Schedule 40 steel pipe capped with an overlapping, threaded, welded steel or iron cap, or be filled with cement.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
A monitoring well owner must repair or seal a damaged monitoring well within seven days after the property owner becomes aware of the damage.
MS s 103I.101; 103I.221; 103I.301; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A monitoring well must terminate at least 12 inches above the established ground surface unless the commissioner determines that no location exists for such a well to provide monitoring information equivalent to an at-grade well.
A monitoring well casing may terminate at-grade only on a roadway, sidewalk, driveway, or a parking area. The location of the well identified by unique well number must be marked on a scaled map with angles and directions from surveyed property corners, a permanent benchmark, or the corners of a permanent structure. The map must be submitted to the commissioner with the well record.
An at-grade monitoring well must be constructed as specified in this subpart.
The well must be contained in a protective manhole cover or vault. The top of the manhole cover or vault must be no less than two inches above the established ground surface.
The established ground surface must be sloped to divert surface water or spills away from the well and to allow for traffic movement and snow plowing.
The manhole cover or vault must be installed in a concrete pad at least four inches in thickness and four feet square or four feet in diameter and of sufficient load-bearing capacity to support vehicular traffic.
The manhole cover or vault must be labeled with the words "Monitoring Well" cast or stamped in letters at least one centimeter or one-half inch in height.
All materials used to construct the manhole cover or vault must be resistant and impervious to water, petroleum products, and chemicals likely to be present.
The well casing must be secured with a locking cap or cover according to part 4725.2250, subpart 17. The manhole cover or vault must be secured with a lock or tamper-resistant bolts.
The well label must be placed on the well casing, manhole cover, or vault, or the unique well number may be stamped on the vault.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
A bored geothermal heat exchanger must be constructed according to the construction standards in this part and the general construction standards in parts 4725.2010 to 4725.3875.
Bored geothermal heat exchanger piping must be high-density polyethylene or cross-linked polyethylene that meets the following requirements:
for high-density polyethylene:
socket fusion and butt fusion connections must be made in accordance with ASTM Standard F2620-19, and electrofusion connections must be made in accordance with ASTM Standard F1055-16; and
for cross-linked polyethylene:
a fitting for a PEXa system must not be buried in a pipe loop boring or between a pipe loop boring and the heat pump unit, unless the fitting is located in a vault or other structure accessible from the ground surface or floor of the building; and
fittings must meet ASTM Standard F1807-19b, ASTM Standard F1960-19a, or ASTM Standard F2080-16, and ASTM Standard F877-20; and
high-density polyethylene and cross-linked polyethylene pipe must have a minimum pressure rating of 160 psi at 73 degrees Fahrenheit.
The licensee must complete a successful pressure test of the bored geothermal heat exchanger piping after the piping is installed in the bore holes. Pipe must be pressure tested with potable water at a pressure of 1.5 times the system operating pressure or 100 psi, whichever is greater. The pressure must remain constant for 30 minutes without adding additional water.
The annular space between the bored geothermal heat exchanger piping and a bore hole must be filled with grout according to the procedures in part 4725.3050, subpart 2, and according to the procedures in part 4725.3450 for a bored geothermal heat exchanger boring from which groundwater flows above the established ground surface. The annular space must be filled with:
neat-cement grout or cement-sand grout in a boring from which groundwater flows above the established ground surface; or
neat-cement grout, cement-sand grout, bentonite grout, or thermally enhanced bentonite grout in unconsolidated materials. Thermally enhanced bentonite grout must consist of:
thermal enhancement material, including:
a maximum of 200 pounds of sand per 50 pounds of bentonite, with 80 percent or more of the sand smaller than 0.0117 inch (passing U.S. Sieve #50); and
a maximum of 20 pounds of graphite that meets the ANSI/NSF Standard 60-2016 requirements per 50 pounds of bentonite.
Heat transfer fluids must be propylene glycol or ethanol that meets the following requirements:
a propylene glycol with additives, including corrosion inhibitors and dyes, must be certified as meeting the NSF Category Code HT1 for heat transfer fluids;
ethanol products must be designed by the manufacturer for use in bored geothermal heat exchanger systems. Ethanol products must not be used unless approved in writing by the commissioner. A complete list of product ingredients and concentrations must be submitted for review;
ethanol may be used in an ethanol-water solution of not more than 20 percent ethanol by volume. Ethanol concentrates used to prepare heat transfer fluid must be diluted to not more than 20 percent ethanol by volume before being brought into a building where the heat transfer fluid is to be used;
storing, handling, and using ethanol is subject to the safety precautions and procedures specified by the ethanol manufacturer, the applicable requirements of chapters 1305 and 7511, and NFPA Standard 30: Flammable and Combustible Liquids Code, 2015 Edition; and
A permanent sign must be attached to the heat pump identifying the heat transfer fluid in the bored geothermal heat exchanger and specifying that only heat transfer fluids approved in this part may be used.
The locations of all buried bored geothermal heat exchanger piping from the point where the pipe loop exits the bore hole to the point where the pipe is exposed above the ground surface or floor of a building must be marked by:
a ferromagnetic metal marker, detectable from the ground surface, located above the point where the pipe loop exits the bore hole.
A bored geothermal heat exchanger boring installed using directional drilling technology that extends under a building or within three feet horizontally of the farthest exterior projection of the building must be located at least ten feet below the lowest part of the building, including the foundation and footings. Supply-return piping that is plumbed through the building wall or floor is exempt from this requirement.
The point where the drill bit penetrates the ground surface for a geothermal heat exchanger boring must be located at least ten feet horizontally from a contaminant source that has contaminants directly entering the soil, including:
Bored geothermal heat exchanger piping must not be installed on or under property other than the property identified in the approved permit without the affected property owner's written consent or other legal authority.
The ends of each pipe loop must be accessible within a building or buried no deeper than ten feet below the ground surface. The buried ends of a pipe loop must not be built over or otherwise made inaccessible.
A pipe loop that is not connected to a geothermal heat exchanger system, such as a loop installed for thermal conductivity testing, must be protected by:
encasing the ends of the pipe loop in an ASTM Schedule 40 steel or plastic outer protective pipe that is at least four inches in diameter and extends at least one foot above and two feet below the ground surface; and
When sealing all or part of a bored geothermal heat exchanger:
all heat transfer fluid must be removed from the bored geothermal heat exchanger piping that is to be sealed;
the heat transfer fluid must be contained and recycled or disposed of according to applicable federal, state, and local requirements;
the ends of each pipe loop must be accessed and grouted by pumping grout through a tremie pipe inserted to within ten feet of the bottom of the loop, or by pumping grout into one end of the loop until grout flowing from the other end of the loop meets the minimum specifications and densities in part 4725.0100, subpart 21d, 22b, or 30n;
the portion of the piping in unconsolidated geologic materials must be filled with bentonite grout, neat-cement grout, or cement-sand grout; and
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211; L 2013 c 108 art 12 s 108; L 2014 c 275 art 1 s 136; 45 SR 986
April 30, 2021
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
An elevator boring must be constructed according to the general construction standards in parts 4725.2010 to 4725.3875 and cased, sealed, and maintained according to this chapter to prevent the vertical movement of water.
The boring is exempt from the requirements in parts 4725.2150; 4725.2175; 4725.2185; 4725.2250, subpart 8, concerning extension of the casing 12 inches above the established ground surface; and 4725.2250, subpart 11.
Hydraulic fluid must be protected from leakage by:
attaching a watertight cap or plate to the bottom of the casing and surrounding the casing with neat-cement or cement-sand grout. The grout must extend at least three inches above and three inches below the bottom of the casing. The grout must be inserted according to part 4725.3050, subpart 2;
grouting the inside of the casing with cement-sand grout or neat-cement grout. The grout must extend at least two feet above the bottom of the casing and be inserted according to part 4725.3050, subpart 2; or
encasing the hydraulic cylinder in a Schedule 30 plastic outer pipe or sleeve with the bottom of the pipe or sleeve capped and the top extending above the pit floor.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
An environmental bore hole must be constructed, repaired, maintained, and sealed according to the general standards in parts 4725.2010 to 4725.3875. In addition, an environmental bore hole that is cased must be constructed to conform to the monitoring well requirements in parts 4725.6650 to 4725.6850.
An environmental bore hole cased and completed at-grade must conform to part 4725.6850.
An environmental bore hole that is not in use or that serves as a potential or actual source of contamination must be sealed according to this chapter.
An environmental bore hole less than 50 feet in depth, in an unconsolidated formation, and not encountering a confining layer may be sealed by removing the casing and screen and allowing the bore hole to collapse, except for a flowing boring which must meet the requirements of part 4725.3850.
The bore hole must not encounter pollution or contamination or have been installed to detect pollution or contaminants.
An environmental bore hole may be constructed to test contaminants without extracting water, or to vent, recover vapor, or sparge contaminants from the water surface, by placing a screen or open hole across the contact of an unconsolidated formation and bedrock according to part 4725.6050, subpart 3.
MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13
17 SR 2773; 33 SR 211
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
[Repealed, 17 SR 2773]
September 2, 2008
Official Publication of the State of Minnesota
Revisor of Statutes