Macerating toilet systems shall comply with ASME A112.3.4 and shall be installed according to the manufacturer's recommendations.
A macerating toilet system may only be installed in one- or two-family dwellings when gravity flow is not possible. Not more than one bathroom group, consisting of a toilet, a lavatory, and a shower or bathtub, may discharge into a macerating toilet system. Components of macerating toilet systems shall be accessible.
The discharge line of a macerating toilet system shall not be less than three-fourths inch.
If the macerating toilet system's vent connection is less than two inches, the vent shall transition to a minimum of two inches immediately after the connection to the system.