A material shall be considered approved if it meets one or more of the standards in subpart 3. All approved materials shall be certified to the listed standard by an independent accredited third-party certification agency. Certification reports shall be made available to the administrative authority when requested. Materials not listed in subpart 3 shall be used only as provided for in part 4715.0330, or as permitted elsewhere in this code.
Abbreviations in this chapter refer to the following:
ANSI, American National Standards Institute, 1899 L Street, NW, 11th Floor, Washington, D.C. 20036;
ASTM, American Society for Testing and Materials, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959;
CSA, Canadian Standards Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6;
CS, Commercial Standards available from: U. S. Department of Commerce, Bureau of Industry and Security, 14th Street & Constitution Avenue NW, Washington, D. C. 20230;
FS, Federal Specifications available from: Federal Supply Service, Standards Division, U.S. General Services Administration, One Constitution Square, 1275 - 1st Street NE, Washington, D. C. 20417;
FHA, Federal Housing Administration, Architectural Standards Division, U.S. Department of Housing & Urban Development, 451 - 7th Street SW, Washington, D. C. 20410;
AASHTO, American Association of State and Highway Transportation Officials, 444 North Capital Street Northwest, Suite 249, Washington, D. C. 20001;
IAPMO, International Association of Plumbing and Mechanical Officials, 4755 E. Philadelphia St., Ontario, CA 91761;
DESCRIPTION | ANSI | ASTM | FS | OTHER | |
I. | CAST IRON PIPE AND FITTINGS | ||||
A21.2 | |||||
A21.6 | A-74 | WW-P-401C | CS188 | ||
1A | Cast Iron Pipe and Fittings Extra Heavy | A21.8 | |||
1B | Cast Iron Pipe Centrifugally Cast Only and Fittings | A21.6 | A-74 | WW-P-401C | CS188 |
Service Weight | A21.8 | ||||
1C | Cast Iron Mechanical | A21.11 | |||
(Gland Type) Pipe | A21.2 | WW-P-421a | |||
A21.6 | |||||
1D | Cast Iron Mechanical | A21.8 | |||
(Gland Type) Pipe Cement Lined | A21.4 A21.2 A21.6 A21.8 |
||||
1E | Cast Iron Short Body Water Service Fittings (2"-12") | A21.10 | AWWA C100 | ||
1F | Cast Iron Threaded Pipe | A40.5 | |||
1G | High Silicon Pipe, Fittings Cast Iron | ||||
1H | Cast Iron Threaded Fittings Black and Galvanized 125# | B16.4 | WW-P-501 | ||
1J | Cast Iron Drainage Fittings Black and Galvanized | B16.12 | WW-P-491 | ||
1K | Hubless Cast Iron Pipe and Fittings | A888-07a | CISPI Standard 301-05 CSA/CAN 3-B70 | ||
1L | Ductile Iron Pipe Flanged | A21.15 | AWWA C115 | ||
1M | Ductile Iron Pipe Push-on Joints, Mechanical Joints | A21.51 | AWWA C151 |
II. | STEEL AND WROUGHT IRON PIPE FITTINGS | ||||
2A | Steel Pipe, Welded and Seamless Galvanized, Schedule 40 and Above | B36.1 | A53 | ||
B36.20 | WW-P-406 | ||||
6(1) | |||||
2B | Wrought Iron Pipe, Galvanized Schedule 40 and Above | B36.2 | |||
2C(a) | Stainless Steel Pipe | B36.19 | |||
2C(b) | Stainless Steel Pipe | A112.3.1 | |||
2D | Galvanized Malleable Fittings 150 psi and Above | B16.3 | A197 | ||
2E | Steel Unions, Galvanized | WW-V-531 C | |||
2F | Corrugated Steel Pipe, Aluminized and Fittings | A760 | AASHTO M36 | ||
(18- to 120-inch) (Storm only) | A796 |
III. | COPPER AND COPPER BASE PIPE AND FITTINGS | ||||
3A | Red Brass Pipe, Regular and Heavier | H27.1 | B42B | ||
3B | Seamless Brass Tube | H36.1 | |||
3C | Brass or Bronze Threaded Fittings 125 lbs. and Over | B16.15 | B62 | WW-P-460 | |
3D | Brass or Bronze Flare Fittings 125 lbs. and Over, Heavy Duty Long Collar Type | B62 | |||
3E | Seamless Copper Tube Type K, Soft Temper | H23.1 | B88 | ||
3F | Seamless Copper Tube Type K, Hard Temper | H23.1 | B88 | ||
3G | Seamless Copper Tube Type L, Soft Temper | H23.1 | B88 | ||
3H | Seamless Copper Tube Type L, Hard Temper | H23.1 | B88 | ||
3H(a) | Welded Copper Alloy | OFT194-101A | |||
194 Water, Tube, Type "Heavy," Hard Temper | B543-72 | Navfac TS-15400 |
|||
3H(b) | Stainless Steel Water Tubing, Type SL, Copper Plated Coating (HWT-T439) | A-651 | |||
3J | Seamless Copper Tube, Type M, Hard and Soft Temper | H23.1 | B88 | ||
3J(a) | Welded Copper Alloy 194 Water | OFT194-101A | |||
Tube, Type "Standard," Hard Temper | B543-72 | Navfac TS-15400 |
|||
3J(b) | Stainless Steel Water | A-268 | |||
Tubing, Type SM, Copper Plated Coating (HWT-T439) | A-651 | ||||
3K | Seamless Copper Tube Type DWV | H23.3 | B306 | ||
3L | Copper Pipe I.P.S. | H26.1 | B42 | ||
3M | Copper Pipe, Threadless Type T P and Fittings | H26.2 | B302 | ||
3N | Cast Bronze and Wrought Solder Joint Pressure Fitting | B16.22 H23.1 B16.18 |
|||
3O | Cast Bronze and Wrought Solder Joint D W V Fittings | B16.23 | |||
3P | Copper Alloy Water Tube 1/2 Inch and 3/4 Inch | B447 B75 |
|||
3Q | Welded Brass Water Tube 1/2 Inch and 3/4 Inch | B587 | |||
3R | Removable and Nonremovable Push-Fit Fittings for Copper Pipe (3/8 to 2 inches only) | NSF 61 ASSE 1061-06 |
IV. | LEAD PIPE AND FITTINGS | ||||
4A | Lead Pipe AA | WW-P-325-44 | |||
4B | Lead Pipe AAA | WW-P-325-44 | |||
4C | Lead Bends and Traps | WW-P-325-44 | |||
4D | Sheet Lead | QQ-L201d |
V. | SILICA AND EARTH PRODUCTS PIPE AND FITTINGS, NONMETALLIC | |||
5A | Asbestos-Cement | C500 | SS-P351 | |
Pressure Pipe and Fitting | C296 | |||
5B | Asbestos-Cement Water Pipe and Fittings | C500 | SS-P-351 | AWWA C400 |
5C | Asbestos-Cement Nonpressure Pipe and Fittings | C428 | XX-P-331 | |
5D | Asbestos-Cement Perforated Underdrain Pipe and Fittings | C508 | ||
5E | Vitrified Clay Pipe, Standard Strength and Stronger Fittings | C13 C200 |
||
5F | Unglazed Clay Pipe, Extra Strength and Fittings | C278 | ||
5G | Perforated Clay Pipe and Fittings | C211 | ||
5H | Borosilicate Glass Pipe and Fittings 60 psi | |||
5J | Nonreinforced Concrete Drain Tile | C412 | AASHTO M178 |
|
5K | Nonreinforced Concrete Pipe | C14 | SS-P-371 | AASHTO M86 CSA-A257.1 |
5L | Perforated Concrete Pipe, Underdrainage | C444 | ||
5M | Reinforced Concrete Pipe | C76 | SS-P-375 | CSA-A257.2 |
5N | Reinforced and Prestressed Concrete Pipe, Pressure Type and Fittings | |||
5O | Bituminized Fiber Drain and Sewer Pipe | D1860 | SS-P-1540A | |
5P | Perforated Bituminized Fiber Pipe for General Drainage | D2311 | SS-P-1540A |
VI. | PLASTIC PIPE AND FITTINGS DRAIN, WASTE AND VENT | |||
6A | Acrylonitrile-Butadiene-Styrene (ABS) | D2661 | L-P-322a FHA-MPS |
NSF14 CSA-B181.1 CS270 |
Type 1, Schedule 40 Cellular core | F628 | |||
6B | (1) Polyvinyl Chloride (PVC) | D2665 | L-P-320a | NSF14 |
Schedule 40 Unthreaded | FHA-MPS | CS272 | ||
Schedule 80 can be threaded | CSA-B181.2 | |||
Cellular core | F891 | |||
Fabricated Fittings (8- to 24-inch) | D3311 | |||
Fabricated Fittings (8-inch and larger with mitered joints 4-inch and larger) | F1866 | |||
6B | (2) Polyvinyl Chloride (PVC) Schedule 30 (3-inch only) | D2949 | L-P-001221 | |
6B | (3) Polyvinyl Chloride (PVC) Schedule 40 (14- to 24-inch only) with ASTM D3311 fittings | D1785 | ||
Fabricated Fittings (8-inch and larger with mitered joints 4-inch and larger) | F1866 | |||
6B | (4) Polyvinyl Chloride (PVC) Schedule 40 and 80 SDR 21 and SDR 26 (6-inch and larger) | D2241 | ||
6B | (5) Corrugated Poly-vinyl Chloride (PVC) Schedule 40 (4- to 36-inch) with ASTM D3212 fittings (Storm only) | F949 | ||
BUILDING SEWER | ||||
6C | (1) Styrene -- Rubber | D2852 | CS228 | |
6C | (2) Polyvinyl Chloride (PVC) | D3034 F789 |
WW-P-00380a | CSA-B182.2 |
(18- to 27-inch only) | F679 | |||
(18-inch and larger) | F794 | |||
6C | (3) Acrylonitrile- Butadiene-Styrene (ABS) |
D2751 | CSA-B182.1 | |
6C | (4) Corrugated High Density Polyethylene (Corrugated HDPE) (4- to 60-inch) with ASTM D3212 fittings (Storm only) | 4- to 10-inch AASHTO M252 12- to 60-inch ASTM F2306 |
WATER SERVICE - Minimum working pressure rating shall be at least 150 psi for municipal water service and 100 psi for other service.
6D | Polyethylene (PE) | B72.1 | D2239 D2737 |
LP-315a FHA-UM-31C |
NSF14 CS255 CSA-B137.1 |
6E | Acrylonitrile- Butadiene-Styrene (ABS) |
B72.3 | D2282 | NSF14 CS254 |
|
6F | Polyvinyl Chloride (PVC) | B72.2 | D2241 D1785 |
L-P-1036 FHA UM-41 |
NSF14 NSF61 AWWA C900 CS256 CSA-B137.3 |
6G | Polybutylene | D2662 D2666 |
NSF14 CSA-B137.7 |
||
6I | Polyethylene/Aluminum/ Polyethylene (PE-AL-PE) Composite Pressure Pipe (up to 1 inch only) |
F1282 | NSF 14 NSF 61 |
WATER DISTRIBUTION - Polybutylene (PB) systems (PB tubing together with recommended fittings) and chlorinated polyvinyl chloride (CPVC) pipe together with fittings must be tested by the manufacturer at 150 psi and 210 degrees Fahrenheit for a period of not less than 48 hours by a qualified independent testing laboratory acceptable to the administrative authority. Cross-linked polyethylene (PEX) tubing systems together with approved fittings must be tested at 150 psi and 210 degrees Fahrenheit for a period of not less than 30 days by a qualified independent testing laboratory acceptable to the administrative authority.
Polypropylene (PP-R) pipe together with fittings must be tested by the manufacturer at 510 psi hoop stress and 203 degrees Fahrenheit for a period of not less than 40 days by a qualified independent testing laboratory acceptable to the administrative authority.
6K | Polybutylene | D3309 | CSA-B137.8 (tubing) | ||
6L | Chlorinated Polyvinyl Chloride (CPVC), Schedule 80 (2-1/2 to 6 inches) | 119.1, 119.2 | D2846 F441 F442 |
NSF14 FHA Bulletin #76 CSA-B137.6 |
|
6M | Cross-linked Polyethylene (PEX) Tubing | F876 |
NSF 14 NSF 61 |
||
6N | (1) Metal Insert Fittings Utilizing a Copper Crimp Ring for PEX Tubing | F1807 | NSF 14 NSF 61 |
||
6N | (2) Cold Expansion Fittings with PEX Reinforcing Rings for Use with PEX Tubing | F1960 | NSF 14 NSF 61 |
||
6N | (3) Cold Expansion Fittings with Metal Compressions Sleeves for Use with PEX Tubing | F2080 | NSF 14 NSF 61 |
||
6N | (4) Stainless Steel Clamps for Securing PEX Tubing to Metal Insert Fittings | F2098-01 | NSF 14 NSF 61 |
||
6N | (5) Plastic Insert Fittings Utilizing a Copper Crimp Ring for PEX Tubing | F2159 | NSF 14 NSF 61 |
||
6N | (6) Cross-linked Polyethylene (PEX) Plastic Hot and Cold Water Distribution Systems | F877 | NSF 14 NSF 61 |
||
6P | Polypropylene (PP-R) | F2389 | NSF 14 NSF 61 |
||
SPECIAL WASTES | |||||
6S | Polyethylene | F1412 | LP 315a | PS10-69 PS11-69 PS12-69 |
|
6T | Polypropylene | F1412 | |||
6U | Polyvinylidene Fluoride (PVDF) | F1673 | |||
6V | Chlorinated Polyvinyl Chloride (CPVC) | IAPMO IGC 210-2005a | |||
GENERAL DRAINAGE | |||||
6W | Polyethylene (corrugated) | F405 |
VII. | FIBERGLASS PIPE AND FITTINGS | ||||
7A | Fiberglass pipe (reinforced thermosetting resin pipe) (one- to 16-inch) (18- to 48-inch must be manufactured in accordance with ASTM D2996) | D2996 | NSF14 NSF61 AWWA C-950 |
MS s 16B.59 to 16B.75; 326.37 to 326.45; 326B.101 to 326B.194; 326B.43 to 326B.49; 326B.52
9 SR 1557; 11 SR 1405; 15 SR 76; 19 SR 590; 23 SR 686; 28 SR 146; L 2007 c 140 art 4 s 61; art 6 s 15; art 13 s 4; L 2008 c 337 s 64; 33 SR 2042; 36 SR 1479
November 13, 2012
Official Publication of the State of Minnesota
Revisor of Statutes