Capital Icon Minnesota Legislature

Office of the Revisor of Statutes

4714.0903 MATERIALS.

UPC section 903.1 is amended to read as follows:

903.1 Applicable Standards. Vent pipes and fittings shall comply with the applicable standards referenced in Table 701.1, except that:

(1) Galvanized steel or 304 stainless steel pipe shall not be installed underground and shall be not less than 6 inches (152 mm) aboveground.

(2) ABS and PVC DWV piping installations shall be in accordance with the applicable standards referenced in Table 1401.1.

Statutory Authority:

MS s 326B.43; 326B.435

History:

40 SR 71

Published Electronically:

January 25, 2016

Official Publication of the State of Minnesota
Revisor of Statutes