UPC section 814.1 is amended to read as follows:
814.1 Condensate Disposal. Where discharged into the drainage system, equipment shall drain by means of an indirect waste pipe.
UPC section 814.5 is amended to read as follows:
814.5 Point of Discharge. Air-conditioning condensate waste pipes shall connect indirectly to the interior drainage system through an air gap or air break to: (1) properly trapped and vented receptors; (2) the tailpiece of an approved plumbing fixture; or (3) an exterior place of disposal approved by the Minnesota Pollution Control Agency.
Condensate waste shall not drain over a public way or in areas causing a nuisance.
40 SR 71; 45 SR 1007
September 27, 2021
Official Publication of the State of Minnesota