Final architectural plans and specifications must include elevations and sections through the building showing types of construction, and must indicate dimensions and assignments of rooms and areas, room finishes, door types and hardware, elevations and details of nurses' stations, utility rooms, toilets and bathing areas, and large-scale layouts of dietary and laundry areas. Plans must show location of fixed equipment and sections and details of elevators, chutes, and other conveying systems. Fire walls and smoke partitions must be indicated. The roof plan must show all mechanical installations. The site plan, if applicable, must indicate the proposed and existing buildings, topography, roadways, walks, and utility service lines.