If hot water is used for sanitization in manual warewashing operations, the sanitizing compartment of the sink must be:
designed with an integral heating device that is capable of maintaining water at a temperature not less than 171 degrees F (77 degrees C);P2 and
provided with a rack or basket to allow complete immersion of equipment and utensils into the hot water.P2
23 SR 519; 43 SR 295
January 2, 2019
Official Publication of the State of Minnesota