In a mechanically refrigerated or hot food storage unit, the sensor of a temperature measuring device shall be located to measure the air temperature in the warmest part of a mechanically refrigerated unit and in the coolest part of a hot food storage unit.
Except as specified in item C, cold or hot holding equipment used for potentially hazardous food shall be designed to include and shall be equipped with at least one integral or permanently affixed temperature measuring device that is located to allow easy viewing of the device's temperature display.
Item B does not apply to equipment for which the placement of a temperature measuring device is not a practical means for measuring the ambient air surrounding the food because of the design, type, and use of the equipment, including calrod units, heat lamps, cold plates, bainmaries, steam tables, insulated food transport containers, and salad bars.
Food temperature measuring devices and water temperature measuring devices on warewashing machines shall have a numerical scale, printed record, or digital readout in increments no greater than 1 degree C or 2 degrees F in the intended range of use.
23 SR 519
October 11, 2007
Official Publication of the State of Minnesota
Revisor of Statutes