ASHRAE Standard 90.1, Section 5.5.3.1, is amended to read:
5.5.3.1 Roof insulation. All roofs shall comply with the insulation values specified in Tables 5.5-1 through 5.5-8. Skylight curbs shall be insulated to the level of roofs with insulation entirely above deck or R-5, whichever is less.
ASHRAE Standard 90.1, Table 5.5-6, Building Envelope Requirements for the Southern Minnesota Climate Zone is amended to read:
TABLE 5.5-6 Building Envelope Requirements For
Southern Minnesota Climate Zone (Zone 6)
Nonresidential | Residential | Semiheated | ||||
Opaque Elements | Assembly Max. | Insulation Min. R-Value | Assembly Max. | Insulation Min. R-Value | Assembly Max. | Insulation Min. R-Value |
Roofs, Insulation | ||||||
Entirely Above Deck | U-0.043 | R-23 ci | U-0.043 | R-23 ci | U-0.06 | R-16.6 ci |
Metal Building | U-0.043 | R-30 | U-0.043 | R-30 | U-0.06 | R-19 |
Attic and Other | U-0.027 | R-30 | U-0.027 | R-30 | U-0.06 | R-19 |
Walls, Above Grade | ||||||
Mass | U-0.104 | R-9.5 ci | U-0.09 | R-11.4 ci | U-0.58 | NR |
Metal Building | U-0.113 | R-13 | U-0.057 | 13 + R-13 | U-0.113 | R-13 |
Steel Framed | U-0.084 | R-13 ci + R-3.8 ci | U-0.064 | R-13 + R-7.5 ci | U-0.124 | R-13 |
Wood Framed and Other | U-0.089 | R-13 | U-0.064 | R-13 + R-3.8 ci |
U-0.089 | R-13 |
Wall, Below Grade | ||||||
Below- Grade Wall | C-0.085 | R-10 ci | C-0.085 | R-10 ci | C-0.085 | R-10 ci |
Floors | ||||||
Mass | U-0.087 | R-8.3 ci | U-0.064 | R-12.5 ci | U-0.322 | NR |
Steel Joist | U-0.038 | R-30 | U-0.038 | R-30 | U-0.069 | R-13 |
Wood Framed and Other | U-0.033 | R-30 | U-0.033 | R-30 | U-.0066 | R-13 |
Slab-On-Grade Floors | ||||||
Unheated | F-0.520 | R-10 to footing* | F-0.520 | R-10 to footing* | F-0.520 | R-10 to footing* |
Heated | F-0.520 | R-10 to footing* | F-0.520 | R-10 to footing* | F-0.520 | R-10 to footing* |
Opaque Doors | ||||||
Swinging | U-0.700 | U-0.500 | U-0.700 | |||
Non- swinging | U-0.500 | U-0.500 | U-1.450 | |||
Fene- stration | Assembly Max. U (Fixed/ Operable) | Assembly Max. SHGC (All Orienta- tions/ North- Oriented) | Assembly Max. U (Fixed/ Operable) | Assembly Max. SHGC (All Orienta- tions/ North- Oriented) | Assembly Max. U (Fixed Operable) | Assembly Max. SHGC (All Orienta- tions/ North- Oriented) |
Vertical Glazing, Percent of Wall | ||||||
0-10.0 | Ufixed -0.57 | SHGCall -0.49 |
Ufixed -0.57 | SHGCall -0.49 |
Ufixed -1.22 | SHGCall -NR |
Uoper -0.67 | SHGCnorth -0.49 |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -1.27 | SHGCnorth -NR |
|
10.1- 20.0 | Ufixed -0.57 | SHGCall -0.39 |
Ufixed -0.57 | SHGCall -0.39 |
Ufixed -1.22 | SHGCall -NR |
Uoper -0.67 | SHGCnorth -0.49 |
Uoper -0.67 | SHGCnorth -0.49 |
Uoper -1.27 | SHGCnorth -NR |
|
20.1- 30.0 | Ufixed -0.57 | SHGCall -0.39 |
Ufixed -0.57 | SHGCall -0.39 |
Ufixed -1.22 | SHGCall -NR |
Uoper -0.67 | SHGCnorth -0.49 |
Uoper -0.67 | SHGCnorth -0.49 |
Uoper -1.27 | SHGCnorth -NR |
|
30.1- 40.0 | Ufixed -0.57 | SHGCall -0.39 |
Ufixed -0.57 | SHGCall -0.39 |
Ufixed -1.22 | SHGCall -NR |
Uoper -0.67 | SHGCnorth -0.49 |
Uoper -0.67 | SHGCnorth -0.49 |
Uoper -1.27 | SHGCnorth -NR |
|
40.1 -50.0 | Ufixed -0.46 | SHGCall -0.26 |
Ufixed -0.46 | SHGCall -0.26 |
Ufixed -0.98 | SHGCall -NR |
Uoper -0.47 | SHGCnorth -0.47 |
Uoper -0.47 | SHGCnorth -0.49 |
Uoper -1.02 | SHGCnorth -NR |
|
Skylight, Percent of Roof | ||||||
0-2.0 | Uall -0.69 | SHGCall -0.49 |
Uall -0.58 | SHGCall -0.49 |
Uall -1.36 | SHGCall -NR |
Greater than 2 to 5.0 | Uall -0.69 | SHGCall -0.49 |
Uall -0.58 | SHGCall -0.39 |
Uall -1.36 | SHGCall -NR |
*"To footing" means to the top of the footing if the insulation is on the exterior, or to the top of the slab if the insulation is on the interior.
ASHRAE Standard 90.1, Table 5.5-7, Building envelope requirements for the northern Minnesota climate zone is amended to read:
Nonresidential | Residential | Semiheated | ||||
Opaque Elements | Assembly Max. | Insulation Min. R-Value | Assembly Max. | Insulation Min. R-Value | Assembly Max. | Insulation Min. R-Value |
Roofs, Insulation | ||||||
Entirely Above Deck | U-0.043 | R-23 ci | U-0.043 | R-23 ci | U-0.06 | R-16.6 ci |
Metal Building | U-0.043 | R-23 | U-0.043 | R-23 | U-0.06 | R-16.6 |
Attic and Other | U-0.043 | R-30 | U-0.043 | R-30 | U-.06 | R-19 |
Walls, Above Grade | ||||||
Mass | U-0.09 | R-9.5 ci | U-0.08 | R-13.3 ci R-13.0 + R- | U-0.58 | NR |
Metal Building | U-0.057 | R-13 | U-0.057 | R-13 R-13 + R-13 |
U-0.113 | R-13 |
Steel Framed | U-0.064 | R-13 + R-3.8 ci | U-0.064 | R-13 + R-7.5 ci | U-0.124 | R-13 |
Wood Framed and Other | U-0.089 | R-13 | U-0.051 | R-13 + R-7.5 ci | U-0.089 | R-13 |
Walls, Below Grade | ||||||
Below- Grade Wall | C-0.085 | R-10 ci | C-0.085 | R-10 ci | C-0.085 | R-10 ci |
Floors | ||||||
Mass | U-0.087 | R-8.3 ci | U-0.064 | R-12.5 ci | U-0.137 | R-4.2 ci |
Steel Joist | U-0.038 | R-30 | U-0.038 | R-30 | U-0.052 | R-19 |
Wood Framed and Other | U-0.033 | R-30 | U-0.033 | R-30 | U-.0066 | R-13 |
Slab-On-Grade Floors | ||||||
Unheated | F-0.52 | R-10 to footing* | F-0.52 | R-10 to footing* | F-0.52 | R-10 to footing* |
Heated | F-0.52 | R-10 to footing* | F-0.52 | R-10 to footing* | F-0.52 | R-10 to footing* |
Opaque Doors | ||||||
Swinging | U-0.70 | U-0.50 | U-0.70 | |||
Non- swinging | U-0.50 | U-0.50 | U-1.45 | |||
Fene- stration | Assembly Max. U (Fixed/ Operable) | Assembly Max. SHGC (All Orienta- tions/ North- Oriented) | Assembly Max. U (Fixed/ Operable) | Assembly Max. SHGC (All Orienta- tions/ North- Oriented) | Assembly Max. U (Fixed/ Operable) | Assembly Max. SHGC (All Orienta- tions/ North- Oriented) |
Vertical Glazing, Percent of Wall | ||||||
0-10.0 | Ufixed -0.57 | SHGCall -0.49 |
Ufixed -0.57 | SHGCall -0.49 |
Ufixed -1.22 | SHGCall -NR |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -1.27 | SHGCnorth -NR |
|
10.1- 20.0 | Ufixed -0.57 | SHGCall -0.49 |
Ufixed -0.57 | SHGCall -0.49 |
Ufixed -1.22 | SHGCall -NR |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -1.27 | SHGCnorth -NR |
|
20.1- 30.0 | Ufixed -0.57 | SHGCall -0.49 |
Ufixed -0.57 | SHGCall -0.49 |
Ufixed -1.22 | SHGCall -NR |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -1.27 | SHGCnorth -NR |
|
30.1- 40.0 | Ufixed -0.57 | SHGCall -0.49 |
Ufixed -0.57 | SHGCall -0.49 |
Ufixed -1.22 | SHGCall -NR |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -0.67 | SHGCnorth -0.64 |
Uoper -1.27 | SHGCnorth -NR |
|
40.1 -50.0 | Ufixed -0.46 | SHGCall -0.36 |
Ufixed -0.46 | SHGCall -0.36 |
Ufixed -0.98 | SHGCall -NR |
Uoper -0.47 | SHGCnorth -0.64 |
Uoper -0.47 | SHGCnorth -0.64 |
Uoper -1.02 | SHGCnorth -NR |
|
Skylight, Percent of Roof | ||||||
0-2.0 | Uall -0.69 | SHGCall -0.68 |
Uall -0.69 | SHGCall -0.64 |
Uall -1.36 | SHGCall NR |
Greater than 2.1 to 5.0 | Uall -0.69 | SHGCall -0.64 |
Uall -0.69 | SHGCall -0.64 |
Uall -1.36 | SHGCall -NR |
*"To footing" means to the top of the footing if the insulation is on the exterior, or to the top of the slab if the insulation is on the interior.
33 SR 1473
June 17, 2009
Official Publication of the State of Minnesota
Revisor of Statutes