GREB Section 604.8 and Exception are deleted in their entirety and replaced with the following:
604.8 Transoms. In corridor walls required to be fire rated by these provisions, existing transoms may be retained if fixed in the closed position and fitted with wired glass set in a steel frame or other approved glazing system.
Exception: Transoms conforming to Section 603 of these provisions shall be accepted.
GREB Section 604.16 is deleted in its entirety and replaced with the following:
604.16 Accessibility requirements. Alterations to a certified historic structure shall comply with Section 403.1.1 unless it is determined, in accordance with the Minnesota Accessibility Code, Minnesota Rules, part 1341.0413, subpart 2, that compliance with the requirements for exterior and interior accessible routes, ramps, entrances, or toilets would threaten or destroy the historic significance of the building or facility, in which case the alternative requirements in Minnesota Rules, part 1341.0413, subpart 3, may be used for the feature.