Table R702.1(3) is amended to read as follows:
TABLE R702.1(3)
CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
CEMENTITIOUS MATERIALS | ||||||
COAT | CEMENT PLASTER TYPE | Portland Cement Type I, II or III or Blended Cement Type IP, I(PM), IS or I(SM) | Plastic Cement | Masonry Cement Type M, S or N | Lime | VOLUME OF AGGREGATE PER SUM OF SEPARATE VOLUMES OF CEMENTI- TIOUS MATERIALSb |
Portland or blended | 1 | 3/4 - 1-1/2a | 2-1/2 - 4 | |||
First | Masonry | 1 | 2-1/2 - 4 | |||
Plastic | 1 | 2-1/2 - 4 | ||||
Portland or blended | 1 | 3/4 - 1-1/2 | 3 - 5 | |||
Second | Masonry | 1 | 3 - 5 | |||
Plastic | 1 | 3 - 5 | ||||
Portland or blended | 1 | 3/4 - 2 | 1-1/2 - 3 | |||
Finish | Masonry | 1 | 1-1/2 - 3 | |||
Plastic | 1 | 1-1/2 - 3 |
For SI: 1 inch = 25.4 mm, 1 pound = 0.545 kg.
a. Lime by volume of 0 to 3/4 shall be used when the plaster will be placed over low-absorption surfaces such as dense clay tile or brick.
b. The same or greater sand proportion shall be used in the second coat than used in the first coat.
Section R702.7 is amended to read as follows:
R702.7 Vapor retarders. A Class I or II vapor retarder is required on the interior side of frame walls in Climate Zones 6 and 7. Class II vapor retarders are permitted only when specified on the construction documents.
39 SR 91