IRC Table R402.2 is amended to read as follows:
TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
TYPE OR |
MINIMUM SPECIFIED COMPRESSIVE STRENGTHa (f ʹc) |
||
LOCATION OF | Weathering Potentialb | ||
CONCRETE CONSTRUCTION | |||
Negligible | Moderate | Severe | |
Footingsg,h | 5,000 | 5,000 | 5,000 |
Basement walls, foundations, and other concrete not exposed to the weather | 2,500 | 2,500 | 2,500c |
Basement slabs and interior slabs on grade, except garage floor slabs | 2,500 | 2,500 | 2,500c |
Basement walls, foundation walls, exterior walls, and other vertical concrete work exposed to the weather | 2,500 | 3,000d | 3,000d |
Porches, carport slabs, and steps exposed to the weather, and garage floor slabs | 2,500 | 3,000d, e, f | 3,500d, e, f |
For SI: 1 pound per square inch = 6.895 kPa.
a Strength at 28 days psi.
b See Table R301.2(1) for weathering potential.
c Concrete in these locations that may be subject to freezing and thawing during construction shall be air-entrained concrete in accordance with footnote "d."
d Concrete shall be air-entrained. Total air content (percent by volume of concrete) shall be not less than 5 percent or more than 7 percent.
e See Section R402.2 for maximum cementitious materials content.
f For garage floors with a steel-troweled finish, reduction of the total air content (percent by volume of concrete) to not less than 3 percent is permitted if the specified compressive strength of the concrete is increased to not less than 4,000 psi.
g Compressive strength (f ʹc) of 2,500 psi, with an approved admixture that provides a water and vapor resistance at least equivalent to 5,000 psi concrete.
h Compressive strength (f ʹc) of 5,000 psi is not required for post footings for decks or porches, wood foundations, slab-on-grade foundation walls, and footings for floating slabs.
39 SR 91; 44 SR 764
March 31, 2020
Official Publication of the State of Minnesota
Revisor of Statutes